{"product_id":"ge-fanuc-ic670mdl730-8-point-24vdc-positive-logic-module","title":"GE Fanuc IC670MDL730 8-Point 24VDC Positive Logic Module","description":"\u003ch2 style=\"color: #1A237E; font-size: 22px; font-weight: bold; margin-bottom: 12px;\"\u003eGE Fanuc Field Control 24VDC 2A ESCP Discrete Output Module (IC670MDL730)\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  The \u003cstrong style=\"color: #0D47A1;\"\u003e\u003cspan style=\"color: #0D47A1;\"\u003eGE Fanuc IC670MDL730\u003c\/span\u003e\u003c\/strong\u003e is an 8-point discrete positive logic output module from the Field Control I\/O series, designed to drive heavy-duty industrial loads up to 2.0 Amps per channel. Operating on a nominal 24 VDC external supply (10 to 30 VDC operating range), this high-current sourcing module incorporates Electronic Short Circuit Protection (ESCP) and supports Pilot Duty applications. Weighing approximately 0.91 kg (2.0 lbs), it features individual logic-side status LEDs, a dedicated PWR indicator, and 250 VAC user-to-logic isolation for robust system protection.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eKey Performance Advantages\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  Provides high output switching capacity with up to 2.0 A current output per point (or 16 A total per module) for direct actuation of solenoids, contactors, and motor starters. Built-in Electronic Short Circuit Protection (ESCP) automatically safeguards internal output circuitry from field wiring overloads and short circuits, eliminating the need for external fuse maintenance.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0; width: 40%;\"\u003eManufacturer \u0026amp; Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eGE Fanuc (Field Control)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePart \/ Catalog Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eIC670MDL730\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eOutput Type \u0026amp; Points\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e24 VDC Sourcing (Positive Logic) \/ 8 Channels (1 Group)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eVoltage Range \u0026amp; Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e10 to 30 VDC Range \/ 2.0 A Continuous per Point (2A Pilot Duty)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eCircuit Protection \u0026amp; Isolation\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eElectronic Short Circuit Protection (ESCP) \/ 250 VAC User to Logic\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eBus Current Draw \u0026amp; Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e80 mA from Bus Interface Unit \/ Approx. 0.91 kg (2.0 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eStatus Indicators\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e8 Point Output Status LEDs, 1 PWR Indicator LED\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eTerminal Base Compatibility\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eBox Terminals or Barrier Terminals Block Base Assembly\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBase Plate Installation:\u003c\/strong\u003e Align the IC670MDL730 module with the terminal block base slot and press firmly until the side locking latches click into place against the Field Control backplane.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring \u0026amp; Power Load:\u003c\/strong\u003e Supply 24 VDC external power to the user terminals to drive connected loads up to 2.0 A per point. Ensure field wiring is rated for high-current loads and wired into appropriate box or barrier terminals.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDiagnostic Monitoring:\u003c\/strong\u003e Observe the front panel \"PWR\" indicator for valid power supply feed and monitor individual point LEDs to verify active output switching and fast diagnostic fault responses.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ1: Has EMC filter?\u003c\/strong\u003e\u003cbr\u003e\n  A1: N\/A (discrete PLC module).\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ2: Key feature vs PF523?\u003c\/strong\u003e\u003cbr\u003e\n  A2: 2A continuous output per point \u0026amp; ESCP protection.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ3: Drives 3-phase motors?\u003c\/strong\u003e\u003cbr\u003e\n  A3: No, drives discrete DC loads and relays.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52655109013636,"sku":"IC670MDL730","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC670MDL730.jpg?v=1786980036","url":"https:\/\/www.etowonauto.com\/it\/products\/ge-fanuc-ic670mdl730-8-point-24vdc-positive-logic-module","provider":"Etowon Auto","version":"1.0","type":"link"}