{"product_id":"allen-bradley-1784-kt-communication-interface-module","title":"Allen-Bradley 1784-KT Communication Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eALLEN-BRADLEY 1784-KT\u003c\/strong\u003e is a specialized Communication Interface Module designed to facilitate high-speed data exchange between host computers and Allen-Bradley industrial controllers. Supporting Data Highway Plus (DH+), PLC-2, and PLC-3 protocols, this module acts as a vital bridge for legacy system integration and real-time monitoring. Engineered for precision, it is a lightweight component with a net weight of only 0.34 kg, making it a low-profile yet powerful addition to industrial communication networks.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eVersatile Communication Protocols\u003c\/h3\u003e\n\u003cp\u003eThe 1784-KT supports both asynchronous and synchronous communication modes. For PLC-2 and PLC-3 systems, it handles asynchronous baud rates of 9600 and 19.2 Kbps. When operating on a Data Highway Plus network, it achieves a synchronous transfer rate of 57.6 Kbps. This versatility allows for short-range local connections (up to 10 ft) or extensive long-distance industrial networking.\u003c\/p\u003e\n\u003ch3\u003eLong-Distance Networking \u0026amp; Reliability\u003c\/h3\u003e\n\u003cp\u003eOne of the primary advantages of the 1784-KT is its ability to maintain signal integrity over vast distances. When configured for Data Highway Plus with PLC-3 or PLC-5 controllers, the module supports communication cable lengths of up to 10,000 feet (3,050 meters). It operates on a dual-voltage DC power requirement, drawing only 2W at +5V DC and less than 0.5W at 12V DC, ensuring minimal thermal impact on the host system.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 25px 0; border: 1px solid #e0e0e0; font-family: inherit;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f4f4f4;\"\u003e\n            \u003cth style=\"border: 1px solid #e0e0e0; padding: 15px; text-align: left; font-size: 15px; color: #333;\"\u003eTechnical Parameter\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #e0e0e0; padding: 15px; text-align: left; font-size: 15px; color: #333;\"\u003eDetailed Rating\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa; width: 40%;\"\u003e\u003cstrong\u003ePower Requirement (5V)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e+5V DC @ 0.4A (2W)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003ePower Requirement (12V)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e12V DC @ 0.04A (0.48W)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eDH+ Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e57.6 Kbps (Synchronous)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eMax Distance (DH+)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e10,000 ft (3,050 meters)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e0°C to 55°C (32°F to 130°F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e0.34 kg (0.75 lbs)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEnvironmental \u0026amp; Operational Stability\u003c\/h2\u003e\n\u003cp\u003eThe 1784-KT is built to withstand standard industrial floor conditions, with an operating humidity range of 5% to 95% (non-condensing). Its thermal design allows for continuous operation in temperatures up to 55°C (130°F). Because of its legacy compatibility, it remains a critical component for maintaining older PLC-2 and PLC-3 installations while providing a pathway to more modern PLC-5 Data Highway Plus networks.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLegacy Connectivity:\u003c\/strong\u003e Provides rare support for PLC-2 and PLC-3 asynchronous communication, preserving existing infrastructure.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh Power Efficiency:\u003c\/strong\u003e Consumes less than 2.5W of total power, reducing the electrical load on the host computer or interface rack.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProven DH+ Performance:\u003c\/strong\u003e Industry-standard 57.6 Kbps synchronous speed ensures reliable data packets for complex automation tasks.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended Reach:\u003c\/strong\u003e Capable of spanning over 3 kilometers of cable without the need for repeaters on DH+ networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the maximum distance for a PLC-2 connection?\u003c\/strong\u003e\u003cbr\u003e\nA1: For PLC-2 and PLC-3 asynchronous connections, the maximum cable distance is limited to 10 feet (3 meters).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does the 1784-KT support PLC-5?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, it supports PLC-5 controllers via the Data Highway Plus (DH+) network protocol at 57.6 Kbps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is any external power supply required?\u003c\/strong\u003e\u003cbr\u003e\nA3: No, the module typically draws its +5V and 12V DC power directly from the host interface slot it is installed in.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050729635972,"sku":"1784-KT","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1784-KT-2.jpg?v=1776947319","url":"https:\/\/www.etowonauto.com\/it\/products\/allen-bradley-1784-kt-communication-interface-module","provider":"Etowon Auto","version":"1.0","type":"link"}