{"product_id":"1762-iq8ow6-allen-bradley-8-input-6-relay-output-module","title":"1762-IQ8OW6 Allen-Bradley 8 Input 6 Relay Output Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eAllen-Bradley 1762-IQ8OW6\u003c\/strong\u003e is a MicroLogix combination I\/O module featuring 8 sink or source input channels and 6 Form A relay outputs. Weighing approximately 280 g, it operates on 10-30 VDC inputs and 5-265 VAC or 5-125 VDC relay outputs for flexible control applications.\u003c\/p\u003e\n\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cp\u003e8 sink or source inputs with 10-30 VDC operating range. 6 Normally Open relay outputs rated for 5-265 VAC and 5-125 VDC. Backplane current draw of 110 mA at 5V DC and 80 mA at 24V DC. Power supply distance rating of 6 modules. Three I\/O groups for organized wiring. Compact 280 g design with 90 x 40.4 x 87 mm dimensions.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eRockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1762-IQ8OW6\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eMicroLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eCombination I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8 Sink \/ Source\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC @ 30°C, 10-26.4 VDC @ 65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e6 Form A Relay (N.O.)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e5-265 VAC, 5-125 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Contact Rating\u003c\/td\u003e\n\u003ctd\u003e2.5 A at 240\/120 VAC, 1.0 A at 125 VDC, 2.0 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMax Current per Module\u003c\/td\u003e\n\u003ctd\u003e8 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackplane Current (5V)\u003c\/td\u003e\n\u003ctd\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eBackplane Current (24V)\u003c\/td\u003e\n\u003ctd\u003e80 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.0 W at 30V, 4.4 W at 26.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eInput Signal Delay\u003c\/td\u003e\n\u003ctd\u003e8 ms (On and Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOutput Switching Delay\u003c\/td\u003e\n\u003ctd\u003e10 ms (On and Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower Supply Distance\u003c\/td\u003e\n\u003ctd\u003e6 Modules Maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e90 x 40.4 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eInstall the \u003cstrong style=\"color: #0066cc;\"\u003e1762-IQ8OW6\u003c\/strong\u003e (approx. 280 g) within 6 slots of the power supply. Wire input devices to the 8 sink or source channels, observing 10-30 VDC rating. Connect relay outputs to loads rated for 5-265 VAC or 5-125 VDC. Maintain continuous current below 8 A per module. Group 1 covers inputs 0-3, Group 2 covers inputs 4-7, and Group 3 covers all outputs for organized wiring.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eCombined input and output channels in one module saves chassis space. Sink or source input flexibility simplifies field device integration. Relay outputs handle both AC and DC loads for versatile control. Lightweight 280 g design reduces mounting strain. Power supply distance rating of 6 modules allows flexible rack placement. Fast 8 ms input and 10 ms output response for responsive control.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many inputs and outputs does the 1762-IQ8OW6 provide?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e It provides 8 sink or source inputs and 6 Form A Normally Open relay outputs.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the output voltage range?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e Relay outputs operate from 5-265 VAC and 5-125 VDC.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e How far can this module be installed from the power supply?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e It must be within 6 modules of the power supply due to its distance rating.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67640763416708,"sku":"1762-IQ8OW6","price":154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1762-IQ8OW6.jpg?v=1792933841","url":"https:\/\/www.etowonauto.com\/it\/products\/1762-iq8ow6-allen-bradley-8-input-6-relay-output-module","provider":"Etowon Auto","version":"1.0","type":"link"}