{"product_id":"tzidc-200-positioner-new-v18348-10111300110-abb","title":"TZIDC-200 Positioner | New V18348-10111300110 ABB","description":"\u003ch2\u003eABB V18348-10111300110 Valve Positioner\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5fb4;\"\u003eV18348-10111300110\u003c\/strong\u003e (also cataloged as the \u003cstrong\u003eV18348\u003c\/strong\u003e Valve Positioner) is a TZIDC-200 digital positioner in a varnished aluminium case with a mechanical position indicator. It accepts a 4-20 mA two-wire input, supports HART and LKS communication, and provides single-acting fail-safe output in an ATEX Ex d II C T4\/T5\/T6 Gb flameproof enclosure. Unit weight is 1.7 kg.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; text-align: left; padding: 10px; border: 1px solid #ccc; background: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 60%; text-align: left; padding: 10px; border: 1px solid #ccc; background: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eV18348-10111300110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eValve Positioner (TZIDC-200)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAluminium, varnished, flameproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Signal\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e4-20 mA, two-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eATEX Ex d II C T4\/T5\/T6 Gb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOutput Function\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSingle acting, fail safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHART, LKS local communication interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePneumatic Connections\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAir pipe: Thread 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCable: Thread 1\/2-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eMount the positioner to a linear actuator per DIN\/IEC 534 \/ NAMUR or to a rotary actuator per VDI\/VDE 3845. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Verify the hazardous area classification matches ATEX Ex d II C T4\/T5\/T6 Gb and maintain cable entry and enclosure integrity for flameproof installation. Connect the 4-20 mA input through the 1\/2-14 NPT cable entry and the air supply through the 1\/4-18 NPT air pipe port. Verify supply air is dry and oil-free at or below the actuator operating pressure before pressurizing. Confirm single-acting fail-safe action by depressurizing the output before placing the loop in service. Route signal wiring separately from AC power conductors. Set actuator spring action, zero position, tolerance band, and dead band through the operator panel or HART configuration before commissioning.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the explosion protection rating of the V18348-10111300110?\u003cbr\u003eA: ATEX Ex d II C T4\/T5\/T6 Gb.\u003c\/p\u003e\n\u003cp\u003eQ: What is the minimum split range and recommended split range?\u003cbr\u003eA: Minimum range 20 % (3.2 mA); recommended range above 50 % (8.0 mA).\u003c\/p\u003e\n\u003cp\u003eQ: What is the unit weight?\u003cbr\u003eA: 1.7 kg.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68144196223108,"sku":"V18348-10111300110","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18348-10111300110.jpg?v=1795616205","url":"https:\/\/www.etowonauto.com\/ha\/products\/tzidc-200-positioner-new-v18348-10111300110-abb","provider":"Etowon Auto","version":"1.0","type":"link"}