{"product_id":"ge-fanuc-ic660bpm100-powertrac-monitor-module","title":"GE Fanuc IC660BPM100 PowerTrac Monitor Module","description":"\u003ch2\u003e\u003cstrong\u003eGE Fanuc IC660BPM100 Power Monitoring Block\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e74b5;\"\u003eGE Fanuc IC660BPM100\u003c\/strong\u003e is a Genius Power Monitoring Block (PMB). It measures RMS values of voltage, current, power, and power factor for 3-phase systems.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand\u003c\/strong\u003e GE Fanuc (Emerson)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel\u003c\/strong\u003e \u003cstrong\u003eIC660BPM100\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e \u003cspan style=\"color: #e67e22;\"\u003e2.5 kg\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType\u003c\/strong\u003e Power Monitor Block\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries\u003c\/strong\u003e Genius I\/O\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage\u003c\/strong\u003e \u003cstrong\u003e115\/230 VAC\u003c\/strong\u003e or \u003cstrong\u003e125 VDC\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMeasurements\u003c\/strong\u003e RMS Voltage, Current, Active\/Reactive Power, KWH, Power Factor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e \u003cstrong\u003e2 per second\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication\u003c\/strong\u003e Genius Bus, up to \u003cstrong\u003e7500 feet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCT Inputs\u003c\/strong\u003e 3 line + 1 neutral current transformers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePT Inputs\u003c\/strong\u003e 3 potential transformers\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBurden\u003c\/strong\u003e \u003cstrong\u003e\u0026lt;0.1 VA\u003c\/strong\u003e per voltage input\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions\u003c\/strong\u003e \u003cstrong\u003e5.21 x 11 x 8.06 inches\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp\u003c\/strong\u003e \u003cstrong\u003e0 to +60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLEDs\u003c\/strong\u003e Unit OK, Communications OK\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive Monitoring\u003c\/strong\u003e Measures RMS values despite harmonics\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Power Input\u003c\/strong\u003e Accepts AC or DC supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-Distance Communication\u003c\/strong\u003e Up to \u003cstrong\u003e7500 feet\u003c\/strong\u003e from host\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandalone Capable\u003c\/strong\u003e Does not require host for monitoring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Insertion\u003c\/strong\u003e Electronics removable without disturbing wiring\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Design\u003c\/strong\u003e Weight \u003cspan style=\"color: #e67e22;\"\u003e2.5 kg\u003c\/span\u003e, industrial enclosure\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSoftware Configurable\u003c\/strong\u003e Easy setup and parameter adjustment\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount in electrical distribution or process equipment\u003c\/li\u003e\n\u003cli\u003eConnect \u003cstrong\u003e115\/230VAC\u003c\/strong\u003e or \u003cstrong\u003e125VDC\u003c\/strong\u003e power\u003c\/li\u003e\n\u003cli\u003eWire up to 3 CTs and 3 PTs (up to AWG #10)\u003c\/li\u003e\n\u003cli\u003eEnsure adequate clearance for wiring and airflow\u003c\/li\u003e\n\u003cli\u003eConnect to Genius Bus (AWG #12 or dual #14)\u003c\/li\u003e\n\u003cli\u003eAllow front access for handheld monitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eIC660BPM100\u003c\/strong\u003e Power Monitoring Block\u003c\/li\u003e\n\u003cli\u003eShipping weight: 3.2 kg\u003c\/li\u003e\n\u003cli\u003eShipped via FedEx UPS DHL\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat parameters does it measure?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt measures \u003cstrong\u003eRMS voltage, current, active\/reactive power, KWH, and power factor\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the weight of the module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWeight is \u003cspan style=\"color: #e67e22;\"\u003e2.5 kg\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat power inputs does it accept?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt accepts either \u003cstrong\u003e115\/230 VAC\u003c\/strong\u003e or \u003cstrong\u003e125 VDC\u003c\/strong\u003e input power.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51515361460356,"sku":"IC660BPM100","price":189.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC660BPM100-1.jpg?v=1770393053","url":"https:\/\/www.etowonauto.com\/ha\/products\/ge-fanuc-ic660bpm100-powertrac-monitor-module","provider":"Etowon Auto","version":"1.0","type":"link"}