{"product_id":"double-acting-positioner-4-20-ma-new-abb-v18345","title":"Double Acting Positioner 4-20 mA | New ABB V18345","description":"\u003ch2\u003eABB V18345-2021421001 TZIDC Electro-Pneumatic Positioner\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color:#1a5fb4;\"\u003eV18345-2021421001\u003c\/strong\u003e (also cataloged as the \u003cstrong\u003eV18345\u003c\/strong\u003e Electro-Pneumatic Positioner) is a TZIDC intelligent positioner in a varnished aluminium case rated IP 65 (NEMA 4X). It accepts a 4-20 mA two-wire HART input and provides double-acting fail-safe output, with ATEX Ex II 2 G EEx ib II C T6 explosion protection. Unit weight is 1.7 kg.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%;border-collapse:collapse;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:40%;text-align:left;padding:10px;border:1px solid #ccc;background:#f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width:60%;text-align:left;padding:10px;border:1px solid #ccc;background:#f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eV18345-2021421001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eTZIDC Electro-Pneumatic Positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eHousing\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eAluminium, IP 65 \/ NEMA 4X, RAL 9005 matte black\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eInput Signal\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e4 to 20 mA, two-wire, HART via FSK module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eATEX Ex II 2 G EEx ib II C T6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eOutput Function\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eDouble acting, fail safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e1.4 to 6 bar (20 to 90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eAir Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e\u0026lt; 0.03 kg\/h \/ 0.015 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003ePneumatic Connections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eThreads G 1\/4 or 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eCable: Thread 1\/2-14 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eDigital Input\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e0-5 V DC logical 0; 11-30 V DC logical 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003eDigital Output\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003e5 to 11 V DC, DIN 19234\/NAMUR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003ePosition Feedback\u003c\/td\u003e\n\u003ctd style=\"padding:10px;border:1px solid #ccc;\"\u003ePlug-in analog module, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSignal and Characteristic Curve Control\u003c\/h3\u003e\n\n\u003cp\u003eThe V18345-2021421001 uses two-wire technology with a nominal 4-20 mA signal range, where 4 mA corresponds to 0 % and 20 mA to 100 % position. Split range operation is freely selectable with a minimum range of 20 % (3.2 mA) and a recommended range above 50 % (8.0 mA). The signal action is configurable as direct (4-20 mA = position 0-100 %) or reverse (20-4 mA = position 0-100 %). The travel characteristic is selectable as linear, equal percentage at 1:25 or 1:50, 25:1 or 50:1, or user-configurable with 20 reference points. The digital input activates a selected protective function when the 24 V DC signal drops below 10 V DC; selectable functions include move to 0 %, move to 100 %, hold last position, disable local configuration, disable local configuration and operation, or disable any access. The HART FSK module enables remote configuration through the 4-20 mA loop. The digital output follows the DIN 19234\/NAMUR control circuit at 5-11 V DC.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\n\u003cp\u003eMount the positioner to a linear actuator per DIN\/IEC 534 \/ NAMUR or to a rotary actuator per VDI\/VDE 3845 using the mechanical position indicator. Verify the hazardous area classification matches ATEX Ex II 2 G EEx ib II C T6 and confirm the input loop is intrinsically safe before wiring. Confirm the 1.7 kg unit is supported by the actuator mounting bracket. Connect the 4-20 mA HART input through the 1\/2-14 NPT cable entry and the air supply through the G 1\/4 or 1\/4-18 NPT port. Verify supply air is dry and oil-free within 1.4 to 6 bar. For double-acting actuators, connect both pneumatic outputs and verify fail-safe action before pressurizing. Route signal wiring separately from AC power conductors and maintain the case seal for IP 65 \/ NEMA 4X integrity. Set split range, characteristic curve, and digital input function through the local panel or HART configuration before placing the loop in service.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003eQ: What is the explosion protection rating of the V18345-2021421001?\u003cbr\u003e\nA: ATEX Ex II 2 G EEx ib II C T6.\u003c\/p\u003e\n\n\u003cp\u003eQ: What is the output function and supply pressure range?\u003cbr\u003e\nA: Double acting, fail safe; supply pressure 1.4 to 6 bar (20 to 90 psi).\u003c\/p\u003e\n\n\u003cp\u003eQ: What is the minimum split range and recommended split range?\u003cbr\u003e\nA: Minimum range 20 % (3.2 mA); recommended range above 50 % (8.0 mA).\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68130824061060,"sku":"V18345-2021421001","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-2021421001.jpg?v=1795097804","url":"https:\/\/www.etowonauto.com\/ha\/products\/double-acting-positioner-4-20-ma-new-abb-v18345","provider":"Etowon Auto","version":"1.0","type":"link"}