{"product_id":"allen-bradley-1756-it6i-controllogix-6-channel-isolated-thermocouple-module","title":"Allen-Bradley 1756-IT6I ControlLogix 6-Channel Isolated Thermocouple Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eAllen-Bradley 1756-IT6I\u003c\/strong\u003e is a premium, high-resolution 6-channel isolated thermocouple input module belonging to the elite ControlLogix automation family. Engineered for precise temperature tracking in harsh processing environments, this module features six individually isolated thermocouple channels alongside an independent Cold-Junction Compensation (CJC) input. Weighing approximately 0.32 kg (0.71 lbs), this compact chassis-mounted module delivers exceptional 16-bit analog-to-digital conversion directly within the ControlLogix backplane system, safeguarding your thermal loops against erratic ground potentials and high-frequency electromagnetic noise without adding substantial structural strain.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndividually Isolated Channels:\u003c\/strong\u003e Features complete channel-to-channel and channel-to-backplane electrical isolation, effectively suppressing common-mode line interference and ground loops to maintain flawless measurement accuracy.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual-Mode High-Resolution Sensing:\u003c\/strong\u003e Delivers a sharp 16-bit diagnostic architecture, providing ultra-fine typical resolution down to 0.7 microvolts per bit when operating within the high-resolution millivolt range.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVersatile Data Representation:\u003c\/strong\u003e Supports multiple processing profiles including left-justified two's complement integer formatting and standard IEEE 32-bit floating-point arrays for seamless controller scaling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAllen-Bradley \/ Rockwell Automation (ControlLogix System)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModel Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1756-IT6I (Series A\/B Compatible)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eGross Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.32 kg (0.71 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eAnalog Inputs Count\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e6 isolated thermocouple inputs and 1 dedicated CJC sensor path\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eStandard Signal Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eminus 12 to plus 78 mV (typical resolution of 1.4 microvolts\/bit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eHigh-Resolution Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eminus 12 to plus 30 mV (typical resolution of 0.7 microvolts\/bit)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBackplane Bus Current\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e250 mA at 5 VDC \/ 125 mA at 24 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMaximum Power Dissipation\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e4.3 Watts maximum under peak operational thermal load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMinimum Module Scan Time\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e10 ms (integer mV), 25 ms (float mV), 50 ms (float temperature)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eRemovable Terminal Blocks\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCompatible with 1756-TBNH and 1756-TBSH mechanical blocks\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Slot Integration:\u003c\/strong\u003e Shut down the primary control rack power supply before installation. Slide the 0.32 kg hardware framework smoothly into any open slot of the ControlLogix chassis, ensuring the top and bottom retention guides are firmly locked onto the structural framing rails.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCJC Terminal Assembly:\u003c\/strong\u003e Wire the external field sensor loops through a compatible 1756-TBNH or 1756-TBSH removable terminal block. Ensure that the dedicated Cold-Junction Compensation (CJC) thermistor is correctly seated and wired to optimize absolute thermal tracking.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eScan Time Optimization:\u003c\/strong\u003e Select the matching data format profile in your Logix Designer programming environment. If executing fast-acting loop dynamics, select the integer millivolt mode to drop the native module processing latency down to a 10 ms cycle.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What structural advantage does channel-to-channel isolation provide on the 1756-IT6I?\u003c\/strong\u003e\u003cbr\u003e\nA1: Channel-to-channel isolation guarantees that each individual thermocouple sensor operates on an independent electrical plane. If one field thermocouple accidentally shorts to a high-voltage metal casing, the resulting surge is confined to that channel, fully protecting the other five sensors and the core PLC processor backplane from cascading failures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Why does this module require a separate CJC input path?\u003c\/strong\u003e\u003cbr\u003e\nA2: A Cold-Junction Compensation input is necessary because terminating thermocouple wires into copper terminal blocks creates secondary thermoelectric junctions. The CJC sensor tracks ambient block temperatures in real time, allowing the internal software to mathematically cancel out terminal errors and maintain accurate sensor telemetry.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the lightweight profile of this module impact its structural stability under high-vibration conditions?\u003c\/strong\u003e\u003cbr\u003e\nA3: No. At only 0.32 kg, its specialized lightweight engineering optimizes the module for dense multi-slot configurations while easily satisfying standard ControlLogix industrial specifications for shock, thermal endurance, and heavy industrial vibration mapping.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050297917572,"sku":"1756-IT6I","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1756-IT6I-3.jpg?v=1782828510","url":"https:\/\/www.etowonauto.com\/ha\/products\/allen-bradley-1756-it6i-controllogix-6-channel-isolated-thermocouple-module","provider":"Etowon Auto","version":"1.0","type":"link"}