{"title":"Tsarin saka idanu na Bently Nevada 3500 Series","description":"\u003cp data-start=\"2351\" data-end=\"2721\"\u003eJerin Bently Nevada 3500 shi ne sanannen tsarin kariyar injuna da aka fi amfani da shi a muhimman aikace-aikacen masana’antu. Wannan rukuni ya haɗa da rakunan 3500, na’urorin samar da wuta, kayan TDI, da katunan sa ido da aka ƙera don ci gaba da sa ido kan jijjiga da yanayin aiki. Waɗannan kayan suna tallafawa tsarin da ke da babban samuwa da ake amfani da su a cikin turbines, compressors, da na’urorin juyawa.\u003c\/p\u003e","products":[{"product_id":"145988-02-bently-nevada-3500-65-temperature-monitor-module","title":"145988-02 Bently Nevada | 3500\/65 Temperature Monitor Module","description":"\u003ch2 style=\"color: #0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0055A4;\"\u003eBently Nevada 3500\/65 Temperature Monitor 145988-02\u003c\/strong\u003e provides critical temperature monitoring for rotating machinery. This module accepts RTD (100Ω Pt) and thermocouple inputs (J, K, T, E, R, S, B) with a range of -50°C to +750°C. It delivers ±1°C accuracy and \u0026lt;1 second response time for reliable bearing and process temperature protection.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eCore Functionality\u003c\/h2\u003e\n\u003cp\u003eThe 3500\/65 monitor continuously tracks temperature inputs and generates alarms when thresholds are exceeded. Each channel features 4 independent alarms with programmable setpoints. It detects open-circuit sensor faults and provides configurable alarm outputs for shutdown or warning systems. The module supports both 2-wire and 3-wire RTD connections with automatic compensation.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; font-size:14px;\"\u003e\n  \u003ctr style=\"background:#f2f2f2;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u003cstrong\u003eValue\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePart Number\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e145988-02\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e3500\/65 Temperature Monitor\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eTemperature Range\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e-50°C to +750°C (-58°F to +1382°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAccuracy\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e±1°C or ±0.5% of reading\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eInput Types\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eRTD (100Ω Pt), TC (J\/K\/T\/E\/R\/S\/B)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eAlarms per Channel\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e4 independent\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eResponse Time\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e\u0026lt;1s (90% step change)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003ePower Supply\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e18-30V DC\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eSensor Connection\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003e2-wire or 3-wire RTD\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background:#f9f9f9;\"\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eCompatibility\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eBently Nevada 3500 Series Racks\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"padding:8px; border:1px solid #ddd;\"\u003eApprox. 0.9 kg (2.0 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003ePower down the 3500 monitoring system before installation. Insert the 145988-02 module into an available slot in the 3500 rack. Connect RTD or thermocouple sensors to the rear terminal block. For 3-wire RTDs, connect all three leads. Configure alarm setpoints via the 3500 configuration software. Verify temperature readings against a known reference.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis monitor provides ±1°C accuracy for precise temperature control. The 4 independent alarms per channel enable flexible protection strategies (alert, danger, and shutdown). Wide input type support (RTD + 7 thermocouple types) covers most industrial temperature sensors. Sub-1-second response ensures rapid detection of thermal events, preventing bearing or winding damage.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #0055A4;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Sensor types supported?\u003c\/strong\u003e\u003cbr\u003e\nA1: RTD (100Ω Pt) and thermocouples J, K, T, E, R, S, B. Both 2-wire and 3-wire RTD connections supported.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Alarm configuration?\u003c\/strong\u003e\u003cbr\u003e\nA2: 4 independent alarms per channel. Programmable setpoints with alert, danger, and shutdown levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Response time?\u003c\/strong\u003e\u003cbr\u003e\nA3: \u0026lt;1 second for 90% step change. Accuracy ±1°C or ±0.5% of reading.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047650164868,"sku":"145988-02","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/145988-02.jpg?v=1787473212"},{"product_id":"3500-33-01-cn-bently-nevada-relay-module-16-channel-output","title":"3500\/33-01-CN Bently Nevada Relay Module - 16 Channel Output","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color:#00529b;font-weight:700;\"\u003eBently Nevada 3500\/33-01-CN 149992-01\u003c\/span\u003e is a 16-channel relay module for 3500 rack systems. It provides alarm and trip outputs for turbines, compressors, and pumps in critical machinery protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e – 16-Channel Relay Module.\u003cbr\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e – Standard 16-Channel Relay Output.\u003cbr\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e – Country-specific approvals (China).\u003cbr\u003e\nFour groups of four channels, switch-selectable for Normally De-energized (ND) or Normally Energized (NE) operation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSPDT, epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5A @ 250Vac \/ 5A @ 125Vdc (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMin. Switched Load\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e100mA @ 5Vdc (standard) \/ 1mA @ 1Vdc (gold)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1200VA @ 250Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e250 Vrms (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRack Space\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eSet each 4-channel group for ND or NE via onboard switches. Use shielded cables for field wiring. For hazardous areas, observe voltage restrictions (30 Vrms max for CSA-only; lower for multiple approvals). Set initial gap voltage to -10 Vdc for standard 3300 XL probes.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eEpoxy-sealed contacts resist dust and corrosion. The module supports SIL-rated safety functions when used with restricted voltage. Seamless integration with 3500 TSI systems and backward-compatible with older 3300 racks (software v3.3+).\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How to check ND vs NE operation?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Measure coil voltage. ND = de-energized in normal state; NE = energized in normal state. Front-panel CH Alarm LED confirms channel status.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What does -CN approval limit?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The -CN suffix indicates China-specific approvals. It may impose lower maximum voltage limits than standard. Refer to the certificate for exact ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can it replace older 3300\/33 modules?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, with rack configuration v3.3+ and Data Acquisition v2.40+. The module is fully backward-compatible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047650328708,"sku":"3500\/33-01-CN","price":210.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-00_149992-01.jpg?v=1787404535"},{"product_id":"bently-nevada-3500-05-01-02-00-00-01-19-inch-rack-14-slots","title":"Bently Nevada 3500-05-01-02-00-00-01 19 Inch Rack 14 Slots","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-05-01-02-00-00-01\u003c\/span\u003e 3500 Series Rack\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-05-01-02-00-00-01\u003c\/span\u003e is a full size 19 inch EIA rack for 3500 monitoring systems. It provides 14 available module slots for power supplies, TDI\/RIM, and monitor modules. Designed for standard 19 inch EIA rack mounting. CE certified for European compliance.\u003c\/p\u003e\n\n\u003ch3\u003eModel Number Decoder\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePosition\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e19 inch Rack (14 module slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e02\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eFull Size Rack for 19 inch EIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e00\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eNo agency approvals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eD\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e00\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eReserved\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eE\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCE Certification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3500-05-01-02-00-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eRack Type\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eFull Size 19 inch EIA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModule Slots\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e19 inch EIA Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eMount rack in standard 19 inch EIA cabinet using four mounting screws. Install power supplies in leftmost slots. Install TDI or RIM in Slot 1. Populate remaining slots with monitor modules. Ensure adequate clearance for rear I\/O modules and cables.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many modules does this rack hold?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e 14 module slots. Power supplies occupy leftmost slots. TDI\/RIM uses Slot 1. Remaining slots for monitor modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the difference between full size and mini rack?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Full size is 19 inch EIA with 14 slots. Mini rack is 12 inch with 7 slots. Choose based on available cabinet space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Does this rack include mounting hardware?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Standard EIA rack mounting screws are required. Bently Nevada does not supply mounting hardware with rack. Use 10-32 or M5 rack screws.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047898841220,"sku":"3500\/05-01-02-00-00-01","price":415.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_05-01-02-00-00-01.jpg?v=1783860938"},{"product_id":"bently-nevada-3500-05-01-02-01-00-01-3500-system-rack","title":"Bently Nevada 3500\/05-01-02-01-00-01 3500 System Rack","description":"\u003ch2 style=\"color: #333333;\"\u003eBently Nevada 3500\/05-01-02-01-00-01 3500 System Rack\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eBently Nevada 3500\/05-01-02-01-00-01\u003c\/strong\u003e is a 3500 System rack for machinery protection monitoring. Enables continuous online monitoring in compliance with API 670 standards. Accommodates power supplies, TDI module, monitor modules, relay modules, and communication modules. Weight: 3.68 kg (8.1 lbs).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3500\/05-01-02-01-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3500 System Rack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eRack Depth\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e349 mm (13.75 inches) standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBulkhead Depth\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e267 mm (10.5 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProtection Rating\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNEMA 4 and 4X options available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3.68 kg (8.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eConfiguration Breakdown\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eRack configuration option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e02\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eMounting type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBackplane configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e00\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eAgency approval option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eAdditional option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eRequired Components\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eOne or two 3500\/15 power supplies\u003c\/li\u003e\n\u003cli\u003e3500\/22M Transient Data Interface module\u003c\/li\u003e\n\u003cli\u003eOne or more 3500\/XX monitor modules\u003c\/li\u003e\n\u003cli\u003e3500\/32M or 3500\/33 relay modules (optional)\u003c\/li\u003e\n\u003cli\u003e3500\/92 communication modules (optional)\u003c\/li\u003e\n\u003cli\u003eI\/O modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eModular design for flexibility and scalability\u003c\/li\u003e\n\u003cli\u003eContinuous online monitoring per API 670 standards\u003c\/li\u003e\n\u003cli\u003eNEMA 4 and 4X protection options available\u003c\/li\u003e\n\u003cli\u003eStandard and bulkhead depth options\u003c\/li\u003e\n\u003cli\u003eAccommodates full range of 3500 monitoring modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eRack Mounting:\u003c\/strong\u003e Secure rack using all mounting holes. Use M6 bolts with 8 N·m torque. Ensure rack is grounded to the panel earth ground before installing modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eModule Installation:\u003c\/strong\u003e Insert modules into designated slots from left to right. Push firmly until latches engage. Do not force modules into incorrect slots.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePower Supply Check:\u003c\/strong\u003e Install at least one 3500\/15 power supply in the leftmost slots. Verify input voltage matches supply rating before energizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eCable Management:\u003c\/strong\u003e Route I\/O cables through bottom or side entries. Maintain 50mm separation from power cables to prevent EMI.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1. Can I mount this rack in a NEMA 4 cabinet?\u003c\/strong\u003e\u003cbr\u003e\nA1. Yes. The rack supports NEMA 4 and 4X protection when installed in a suitable enclosure with proper seals and gaskets.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2. How many modules can this rack hold?\u003c\/strong\u003e\u003cbr\u003e\nA2. The standard 3500 rack accommodates up to 16 modules depending on module width and configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3. What is the difference between standard and bulkhead depth?\u003c\/strong\u003e\u003cbr\u003e\nA3. Standard depth is 349mm for panel mounting. Bulkhead depth is 267mm for through-wall mounting in restricted spaces.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eDownload\u003c\/h3\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-05.pdf?v=1740031707\" style=\"color: #333333; text-decoration: none; font-weight: bold;\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047898873988,"sku":"3500\/05-01-02-01-00-01","price":367.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_05-01-02-01-00-01.jpg?v=1783854822"},{"product_id":"3500-15-03-03-02-bently-nevada-high-voltage-dc-psu","title":"3500\/15-03-03-02 Bently Nevada High Voltage DC PSU","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15-03-03-02 Power Supply Module\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15-03-03-02\u003c\/strong\u003e is a high voltage DC power supply module for 3500 rack systems. Both top and bottom slots use Legacy High Voltage DC (88 to 140 V DC). ATEX IECEx CSA Zone 2 certified. Module weight 1.39 kg.\u003c\/p\u003e\n\u003ch3\u003eModel Number Breakdown\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eOption Code\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e03 (Top Slot)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eLegacy High Voltage DC (88 to 140 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e03 (Bottom Slot)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eLegacy High Voltage DC (88 to 140 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e02 (Agency Approval)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eATEX \/ IECEx \/ CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/15-03-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePower Supply Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHigh Voltage DC (88 to 140 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e20 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eATEX, IECEx, CSA Class 1 Zone 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-20°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual high voltage DC supplies in top and bottom slots\u003c\/li\u003e\n\u003cli\u003e88 to 140 V DC input range\u003c\/li\u003e\n\u003cli\u003eATEX IECEx CSA Class 1 Zone 2 certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003eRedundant configuration for continuous operation\u003c\/li\u003e\n\u003cli\u003eHalf-height module for 3500 rack left side slots\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDC Wiring:\u003c\/strong\u003e Connect DC positive to + terminal, negative to - terminal. Use 14-16 AWG copper wire. Torque terminals to 0.5 Nm. Verify voltage between 88-140 V DC before energizing. Under-voltage does not damage module; over-voltage opens internal PIM fuse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHazardous Area Installation:\u003c\/strong\u003e For Class 1 Zone 2 installations, use appropriately rated cable glands and seals. Ensure rack ground connection to plant earth. Follow ATEX IECEx installation requirements for area classification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Test:\u003c\/strong\u003e Both supplies operate in parallel. Remove one supply to verify other powers full rack load. Supply OK LED indicates proper operation.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What DC voltage range does 3500\/15-03-03-02 accept?\u003c\/strong\u003e\u003cbr\u003eA1: 20 to 30 V DC input. Module converts to high voltage DC for rack operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What certifications does this module hold?\u003c\/strong\u003e\u003cbr\u003eA2: ATEX, IECEx and CSA Class 1 Zone 2 certified for hazardous area installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can both supplies run simultaneously?\u003c\/strong\u003e\u003cbr\u003eA4: Yes. Both top and bottom slots can hold supplies for redundant parallel operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047898972292,"sku":"3500\/15-03-03-02","price":158.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-03-03-02.jpg?v=1783752293"},{"product_id":"3500-15-133292-01-bently-nevada-low-voltage-dc-power-supply","title":"3500\/15 133292-01 Bently Nevada Low Voltage DC Power Supply","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 133292-01 Low Voltage DC Power Supply\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 133292-01\u003c\/strong\u003e is a low voltage DC power supply module for 3500 rack systems. Input voltage 20 to 30 V DC. Full rack current draw 11 A maximum. Two half-height slots allow redundant power supply configuration. Module weight 1.39 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/15 133292-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eLow Voltage DC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e20 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e11.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMinimum Loading\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNo minimum rack load required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 x 50.8 x 251.5 mm (4.75 x 2.0 x 9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow voltage DC input 20 to 30 V DC\u003c\/li\u003e\n\u003cli\u003e11 A maximum full rack current draw\u003c\/li\u003e\n\u003cli\u003eTwo half-height slots for redundant power supplies\u003c\/li\u003e\n\u003cli\u003eNo minimum rack load required\u003c\/li\u003e\n\u003cli\u003eUnder-voltage does not harm supply or PIM\u003c\/li\u003e\n\u003cli\u003eOver-voltage causes fuse to open on PIM\u003c\/li\u003e\n\u003cli\u003eSupply OK front panel LED indicator\u003c\/li\u003e\n\u003cli\u003eDNV GL and ABS maritime certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRack Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo half-height slots on left side of rack\u003c\/li\u003e\n\u003cli\u003eEach slot accommodates one power supply\u003c\/li\u003e\n\u003cli\u003eBoth slots can hold power supplies simultaneously for redundancy\u003c\/li\u003e\n\u003cli\u003ePower Input Module (PIM) located directly behind associated power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the input voltage range and full rack current draw?\u003c\/strong\u003e\u003cbr\u003eA1: 20 to 30 V DC input. Full rack current draw 11.0 A maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the power supply dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eA2: Dimensions 120.7 x 50.8 x 251.5 mm. Weight 1.39 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can two power supplies be installed for redundancy?\u003c\/strong\u003e\u003cbr\u003eA3: Yes. Both half-height slots can hold power supplies simultaneously for redundant configuration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899005060,"sku":"133292-01","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15_133292-01.jpg?v=1783249602"},{"product_id":"3500-15-03-03-00-bently-nevada-high-voltage-dc-power-supply","title":"3500\/15-03-03-00 Bently Nevada High Voltage DC Power Supply","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-15-03-03-00\u003c\/span\u003e 3500\/15 Power Supply Module\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-15-03-03-00\u003c\/span\u003e is a 3500\/15 series power supply module. It features dual high voltage DC inputs with 88 to 140 Vdc operating range. Half-height module installs in left rack slots. Supports redundant configuration with lower slot as primary and upper as backup. Hot swappable with second supply installed.\u003c\/p\u003e\n\n\u003ch3\u003eModel Number Decoder\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePosition\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e03\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eLegacy High Voltage DC (88 140 Vdc) Top Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e03\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eLegacy High Voltage DC (88 140 Vdc) Bottom Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e00\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eNo agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3500-15-03-03-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eTop Slot Input\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e88 140 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBottom Slot Input\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e88 140 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e2.5 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDimensions H x W x D\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e95% non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eInstall power supplies in leftmost rack slots. Lower slot is primary, upper is backup. Insert PIM directly behind associated supply. Both supplies can be installed for redundancy. Removing or inserting one supply does not disrupt rack operation if second supply is installed.\u003c\/p\u003e\n\n\u003ch3\u003eWiring\u003c\/h3\u003e\n\u003cp\u003eConnect DC input to PIM terminals. Use 14 AWG copper wire for DC connections. Observe polarity marking on PIM. Over voltage causes fuse to open on PIM. Under voltage does not harm supply or PIM. Secure wires with proper strain relief.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Can I hot swap the power supply?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Yes. Removing or inserting either module does not disrupt rack operation as long as a second supply is installed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What happens during over voltage?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Fuse opens on PIM protecting the system. Replace fuse with same rating. Identify and correct input voltage fault before reinstallation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the primary backup configuration?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Lower slot acts as primary supply. Upper slot acts as backup. Both supplies can power a full rack independently.\u003c\/p\u003e\n\n\u003ch3\u003eDownload\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\" style=\"color: #2980b9; font-weight: bold;\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899070596,"sku":"3500\/15-03-03-00","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-03-03-00.jpg?v=1783750044"},{"product_id":"bently-nevada-3500-15-04-04-00-power-supply-15w","title":"Bently Nevada 3500\/15-04-04-00 Power Supply 15W","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/15-04-04-00 Power Supply Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 3500\/15-04-04-00\u003c\/strong\u003e is a low voltage DC power supply module for 3500 Series machinery monitoring systems. Provides stable 15W output with 85% efficiency and dual slot redundancy. Designed for harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e20-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e15W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eRipple Noise\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e50 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eDual low voltage slots for system redundancy\u003c\/li\u003e\n\u003cli\u003ePrevents unexpected machine shutdowns\u003c\/li\u003e\n\u003cli\u003eBuilt for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eNo tools required for module swap\u003c\/li\u003e\n\u003cli\u003eProtects sensitive vibration sensors from power dips\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I install the 3500\/15-04-04-00 in the rack?\u003c\/strong\u003e\u003cbr\u003eA1: Slide the module into the left-side half-height slot until it clicks. Secure with the two captive screws. For redundancy, install a second unit in the adjacent slot. No power-down required for hot-swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the recommended wiring for DC input?\u003c\/strong\u003e\u003cbr\u003eA2: Use 14-16 AWG twisted pair for DC input. Connect positive to pin 1, negative to pin 2. Keep cable length under 3 meters to minimize voltage drop. Tighten terminal screws to 0.5 Nm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I verify proper operation after installation?\u003c\/strong\u003e\u003cbr\u003eA3: Check the Supply OK LED on the front panel. Green indicates normal. If LED is off, verify input voltage is between 20-30Vdc and polarity is correct. Measure output at test points before connecting load.\u003c\/p\u003e\n\n\u003cp style=\"margin-top:20px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\" style=\"display:inline-block; background-color:#0066b3; color:white; padding:10px 20px; text-decoration:none; border-radius:4px;\"\u003eDownload Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899299972,"sku":"3500\/15-04-04-00","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-04-04-00.jpg?v=1783746480"},{"product_id":"3500-15-05-00-00-power-supply-bently-nevada","title":"3500\/15-05-00-00 Power Supply Bently Nevada","description":"\u003ch2 style=\"color: #333333;\"\u003eBently Nevada 3500\/15-05-00-00 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eBently Nevada 3500\/15-05-00-00\u003c\/strong\u003e is a power supply module for the 3500 monitoring system. Features Universal AC Voltage (85-264V AC) in both top and bottom slots for redundant operation. Weight: 1.39 kg (3.1 lbs).\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3500\/15-05-00-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eTop Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eUniversal AC (85-264V AC rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBottom Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eUniversal AC (85-264V AC rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCurrent Draw (Full Rack)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e2.8A RMS maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e120.7 × 50.8 × 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e1.39 kg (3.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003ePower Input Module Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e120.7 × 25.4 × 114.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e05\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eUniversal AC (85-264V AC) - Top Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e05\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eUniversal AC (85-264V AC) - Bottom Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e00\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNo agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual universal AC power supplies for redundant operation\u003c\/li\u003e\n\u003cli\u003eWide input range 85-264V AC, 47-63 Hz\u003c\/li\u003e\n\u003cli\u003eFull rack current capacity 2.8A RMS maximum\u003c\/li\u003e\n\u003cli\u003eCompact form factor for standard 3500 rack installation\u003c\/li\u003e\n\u003cli\u003eHot-swappable for online replacement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Top and bottom slots both require Universal AC supplies. Insert modules into designated slots and lock latches.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect AC input to L1 and L2 terminals. Use 14 AWG minimum wire. Torque terminals to 0.8 N·m (7 in·lb). Connect earth ground to chassis ground lug.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Check:\u003c\/strong\u003e Verify 85-264V AC between L1 and L2 before energizing. Frequency must be 47-63 Hz.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Dual supplies provide true redundancy. Remove one supply during operation to test failover. System continues running without interruption.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Budget:\u003c\/strong\u003e Each AC supply provides 2.8A RMS maximum. Calculate total rack load before adding modules.\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Can I replace one supply while the rack is powered?\u003c\/strong\u003e\u003cbr\u003eA1. Yes. The 3500\/15 supports hot-swap. Remove the faulty supply, insert the new one, and it automatically synchronizes. No system shutdown required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What happens if both supplies fail?\u003c\/strong\u003e\u003cbr\u003eA2. If both supplies fail, the rack loses power. Install a new supply within 30 seconds to maintain monitoring. Longer downtime requires system restart.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Can I mix Universal AC and DC supplies?\u003c\/strong\u003e\u003cbr\u003eA3. No. This configuration uses Universal AC in both slots. Mixing AC and DC requires a different part number with appropriate slot codes.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899332740,"sku":"3500\/15-05-00-00","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-00-00.jpg?v=1783759283"},{"product_id":"bently-nevada-ac-power-supply-3500-15-05-05-00","title":"Bently Nevada na’urar samar da wuta ta AC | 3500\/15-05-05-00","description":"\u003ch2\u003eTakaitaccen Bayanin Samfuri\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cstrong\u003eBently Nevada 3500\/15-05-05-00\u003c\/strong\u003e wata na'urar samar da wuta ce mai babban sahihanci (high-availability) ga 3500 Machinery Protection System. Wannan daidaitaccen zayyana na ɗauke da \u003cstrong\u003emasu samar da wutar Universal AC biyu masu madadin (redundant)\u003c\/strong\u003e, suna karɓar faɗin zangon shigar wuta na 85 zuwa 264 Vac rms.\n\u003c\/p\u003e\n\u003cp\u003e\n  An yi shi da alfahari \u003cstrong\u003ea U.S.A.\u003c\/strong\u003e, module ɗin 3500\/15 sashi ne mai tsayin rabin tsawo wanda ke mamaye ramuka biyu a gefen hagu na rak ɗin 3500. An ƙera shi ne don tabbatar da ci gaba da aiki na muhimman na'urorin saka idanu ko da idan wutar tushe ɗaya ta gaza.\n\u003c\/p\u003e\n\n\u003ch2\u003eTsarin Fasaha\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSamfuri:\u003c\/strong\u003e 3500\/15 Power Supply\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRami A (Sama):\u003c\/strong\u003e 05 - Universal AC Voltage (85 zuwa 264 Vac rms)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRami B (Ƙasa):\u003c\/strong\u003e 05 - Universal AC Voltage (85 zuwa 264 Vac rms)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmincewar Hukuma:\u003c\/strong\u003e 00 - Babu (Standard Industrial)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNau'in Module:\u003c\/strong\u003e Universal AC Power Supply da PIM (Power Input Module)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eBayani na Fasaha\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eMa'auni\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eCikakkun Bayani\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e85 zuwa 264 Vac rms (Universal)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e47 zuwa 63 Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eMatsakaicin Ƙarfin Ƙarfi\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e2.8 A rms (Mafi yawa)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eZafin Aiki\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e-30°C zuwa +65°C (-22°F zuwa +150°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eGirma (H x W x D)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eNauyin Module\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eHaɗin Tsari \u0026amp; Alamomi\u003c\/h2\u003e\n\u003cp\u003e\n  Bangaren gaban yana da \u003cstrong\u003eSupply OK LED\u003c\/strong\u003e, wadda ke haskawa idan wutar tana aiki cikin yanayin da aka saba. Wannan na'urar ba ta buƙatar ƙaramar nauyin rak, wanda ke ba da damar amfani da ita cikin sauƙi a cikin ƙananan rak da kuma rak na 3500 da aka cika gaba ɗaya.\n\u003c\/p\u003e\n\n\u003ch2\u003eMuhimman Fa'idodi\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCikakkiyar Wutar Madadin:\u003c\/strong\u003e 3500\/15-05-05-00 na ɗauke da masu samar da wuta guda biyu, yana tabbatar da tsarin ya ci gaba da aiki idan ɗaya ta gaza.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFaɗin Dacewa:\u003c\/strong\u003e Universal AC PIM (Power Input Module) yana sarrafa sauye-sauyen da ke cikin layukan wutar lantarki na duniya.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eƘirar da ta daure:\u003c\/strong\u003e An gina ta don yanayin masana'antu mai tsananin zafi da wuraren da ke da yawan danshi (har zuwa kashi 95% ba tare da gamsuwa ba).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTambayoyin Fasaha (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Shin wannan ya dace da tsofaffin na'urorin High ko Low voltage?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: A'a. Universal AC Power Supply da PIM ba su dace da tsofaffin High Voltage AC ko Low Voltage AC units ba. Tabbatar bangon bayanka ya dace.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Zan iya cire waɗannan na'urorin ina kunne (hot-swap)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Ee, a cikin tsarin da ake da wutar madadin (kamar wannan samfurin 05-05), za a iya cire ɗaya daga cikin masu samar da wuta a maye gurbinsa yayin da ɗayan ke ci gaba da ba da wuta ga rak.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Shin wannan na'urar tana ƙunshe da Power Input Module (PIM) na bangon baya?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Wannan jerin ya ƙunshi daidaiton 3500\/15-05-05-00 wanda aka ƙera don aiki tare da Universal AC PIM da yake kai tsaye a bayan wutar samarwa.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eZazzage Datasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf\" target=\"_blank\"\u003eSamun Takardun Fasaha na PDF 3500\/15\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899398276,"sku":"3500\/15-05-05-00","price":341.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-05-00.jpg?v=1775899743"},{"product_id":"3500-15-05-05-01-bently-nevada-3500-system-psu-65w","title":"3500\/15-05-05-01 | Bently Nevada 3500 System PSU 65W","description":"\u003ch2\u003e3500-15-05-05-01 Bently Nevada Power Supply Module – 85-264VAC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eBently Nevada 3500\/15-05-05-01\u003c\/strong\u003e is a universal AC power supply module for the 3500 Monitoring System. Accepts 85 to 264 VAC input. CSA\/NRTL\/C approved for Class 1, Division 2 hazardous areas.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e3500\/15-05-05-01\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePower Supply Module\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003ePower Supply Type (Top Slot)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eUniversal AC (85-264 Vac rms)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003ePower Supply Type (Bottom Slot)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eUniversal AC (85-264 Vac rms)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCSA \/ NRTL \/ C (Class 1, Division 2)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e12 Months\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eLength\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e251.5 mm (9.9 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e120.7 mm (4.75 in)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUniversal AC input 85-264 VAC\u003c\/li\u003e\n  \u003cli\u003eCSA\/NRTL\/C approved for Class 1 Division 2\u003c\/li\u003e\n  \u003cli\u003eAdvanced heat dissipation technology\u003c\/li\u003e\n  \u003cli\u003eCompact design for easy integration\u003c\/li\u003e\n  \u003cli\u003eReliable power for 3500 Monitoring System\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3500 Monitoring System racks\u003c\/li\u003e\n  \u003cli\u003eTurbine supervisory systems\u003c\/li\u003e\n  \u003cli\u003eCompressor monitoring\u003c\/li\u003e\n  \u003cli\u003ePower generation facilities\u003c\/li\u003e\n  \u003cli\u003eOil and gas installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Which rack slot for installation?\u003c\/strong\u003e\u003cbr\u003e\nA1: Install in the leftmost slot of the 3500 rack. Both top and bottom slots support universal AC. Secure with two captive screws at 0.56 N·m (5 in·lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How to wire AC input correctly?\u003c\/strong\u003e\u003cbr\u003e\nA2: Use 14-16 AWG 90°C wire. Connect L to terminal 1, N to terminal 2, Ground to terminal 3. Torque terminals to 0.56 N·m. Always verify 85-264 VAC before energizing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Green LED off. What to check?\u003c\/strong\u003e\u003cbr\u003e\nA3: Check AC voltage at terminals. If present but green off, internal fuse is blown. This is a sealed module – replace the entire power supply. Do not attempt field repair.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Documentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\" style=\"color:#0066cc; font-weight:bold;\"\u003eDownload Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899431044,"sku":"3500\/15-05-05-01","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-05-01.jpg?v=1783751013"},{"product_id":"bently-nevada-3500-15-05-05-05-r0-power-supply","title":"Bently Nevada 3500\/15-05-05-05-R0 Power Supply","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/15-05-05-05-R0 Power Supply Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 3500\/15-05-05-05-R0\u003c\/strong\u003e is a universal AC power supply module for 3500 Series machinery monitoring systems. Features dual redundant slots with 85-264 Vac input capability. Ensures continuous power for critical monitoring applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Voltage (Top Slot)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e85-264 Vac rms (Universal AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Voltage (Bottom Slot)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e85-264 Vac rms (Universal AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eDimensions\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHeight x Width x Depth\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInches\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e4.75 x 2.0 x 9.9 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eDual redundant power supply configuration (top and bottom slots)\u003c\/li\u003e\n\u003cli\u003eUniversal AC input covers global power standards\u003c\/li\u003e\n\u003cli\u003eCompact design for easy rack installation\u003c\/li\u003e\n\u003cli\u003eEnsures continuous power for critical monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the input voltage range for the 3500\/15-05-05-05-R0?\u003c\/strong\u003e\u003cbr\u003eA1: Both top and bottom slots accept 85-264 Vac rms universal AC input.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the weight of this module?\u003c\/strong\u003e\u003cbr\u003eA2: 1.39 kg (3.06 lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can this module be used with both top and bottom slots simultaneously?\u003c\/strong\u003e\u003cbr\u003eA3: Yes, both slots are populated with universal AC power supplies for full redundancy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899463812,"sku":"3500\/15-05-05-05-R0","price":221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-05-05-R0.jpg?v=1783758272"},{"product_id":"bently-nevada-transient-data-interface-3500-22-01-01-00","title":"Bently Nevada Transient Data Interface 3500\/22-01-01-00","description":"\u003ch2\u003e3500-22-01-01-00 Bently Nevada Transient Data Interface – 288055-01 + 146031-01\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eBently Nevada 3500\/22-01-01-00\u003c\/strong\u003e is a Transient Data Interface for the 3500 Monitoring System. Includes TDI module (288055-01) with USB cable and 10Base-T\/100Base-TX Ethernet I\/O module (146031-01).\u003c\/p\u003e\n\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e3500\/22-01-01-00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eTransient Data Interface\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eTDI Module\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e288055-01 (Standard with USB Cable)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eI\/O Module\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e146031-01 (10Base-T\/100Base-TX Ethernet)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eTransient Data Interface Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eStandard (01)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eI\/O Module Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e10Base-T\/100Base-TX Ethernet (01)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eAgency Approval\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eNone (00)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e10.5 Watts\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWeight (Total)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e1.11 kg (TDI 0.91 kg + I\/O 0.20 kg)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions (D x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e24.18 x 2.44 x 24.13 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e95% Non-Condensing\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eBattery Life (Powered)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e38 Years at 50°C (122°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eBattery Life (Unpowered)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e12 Years at 50°C (122°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCommunications\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e10Base-T\/100Base-TX Ethernet (RJ-45)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eFront Panel\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eUSB-B (Configuration Port)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOK Relay Rating\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e5A @ 24 Vdc\/120 Vac, 120W\/600VA\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eCombines RIM function with data collection capability\u003c\/li\u003e\n  \u003cli\u003e10Base-T\/100Base-TX Ethernet communication\u003c\/li\u003e\n  \u003cli\u003eUSB-B front panel configuration port\u003c\/li\u003e\n  \u003cli\u003eSupports steady state and transient dynamic waveform data\u003c\/li\u003e\n  \u003cli\u003eOK relay indicates rack operating status\u003c\/li\u003e\n  \u003cli\u003eRack reset button for clearing latched alarms\u003c\/li\u003e\n  \u003cli\u003eAddress switch with 127 possible addresses\u003c\/li\u003e\n  \u003cli\u003eConfiguration keylock for RUN\/PROGRAM modes\u003c\/li\u003e\n  \u003cli\u003eLong battery life for extended operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eInstalls in Slot 1 (adjacent to power supplies) of the 3500 rack\u003c\/li\u003e\n  \u003cli\u003eWhen upgrading from RIM to TDI: Remove RIM, remove RIM I\/O, insert TDI I\/O, insert TDI\u003c\/li\u003e\n  \u003cli\u003eUSB cable (123M4610) required for isolation – computer must run on batteries to avoid ground loops\u003c\/li\u003e\n  \u003cli\u003eSignal Common grounding: Use 2-pin connector, slide PIM switch to \"HP\" position\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the upgrade sequence from RIM to TDI?\u003c\/strong\u003e\u003cbr\u003e\nA1: Remove RIM, remove RIM I\/O, insert TDI I\/O, insert TDI. Leaving RIM I\/O in rack will damage the TDI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What USB cable is required and why?\u003c\/strong\u003e\u003cbr\u003e\nA2: Use 123M4610 USB cable. Computer must run on batteries to maintain isolation and avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How to connect Signal Common to Instrument Ground?\u003c\/strong\u003e\u003cbr\u003e\nA3: Use the 2-pin connector on I\/O module. Slide the PIM switch toward \"HP\" to isolate Signal Common from chassis ground.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Documentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" target=\"_blank\" style=\"color:#0066cc; font-weight:bold;\"\u003eDownload Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899529348,"sku":"3500\/22-01-01-00","price":335.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22-01-01-00.jpg?v=1783851190"},{"product_id":"bently-nevada-3500-22-01-03-00-tdi-module-ethernet-i-o","title":"Bently Nevada 3500\/22-01-03-00 TDI Module Ethernet I\/O","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eBently Nevada 3500\/22M Transient Data Interface Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22M TDI Module\u003c\/b\u003e delivers high-speed transient data capture for critical turbomachinery. It captures waveform snapshots and event-triggered records, enabling advanced diagnostics for gas turbines, compressors, and steam turbines. This module serves as the communication gateway between the 3500 rack and plant management systems, ensuring continuous monitoring and predictive maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eOrdering Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22M\u003c\/b\u003e part number follows this structure: \u003cb style=\"color: #0056b3;\"\u003e3500\/22-AA-BB-CC\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eAA – Transient Data Interface Type:\u003c\/b\u003e 01 = Standard (for standard monitoring applications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eBB – I\/O Module Type:\u003c\/b\u003e 01 = 10Base-T\/100Base-TX Ethernet, 02 = 100Base-FX Fiber Optic, 03 = Ethernet with gold-plated OK relay, 04 = Fiber with gold-plated OK relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eCC – Agency Approval:\u003c\/b\u003e 00 = None, 01 = CSA\/NRTL\/C (Class 1 Div 2), 02 = Multi (CSA, ATEX, IECEx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModule Dimensions (TDI)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTDI Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Powered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e38 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Unpowered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eInstall the TDI module in a full-height front slot; the matching I\/O module occupies one full-height rear slot.\u003c\/li\u003e\n\u003cli\u003eUse twisted-pair shielded cables for Ethernet connections; maintain a minimum bend radius of 10x cable diameter.\u003c\/li\u003e\n\u003cli\u003eFor fiber optic variants (100Base-FX), clean connectors with lint-free wipes and inspect for \u0026lt; 0.5 dB loss.\u003c\/li\u003e\n\u003cli\u003eWhen replacing a legacy 3500\/22, ensure the firmware revision is updated to support the new I\/O options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 3500\/22M\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eProvides buffered transient data for post-event analysis and predictive trending.\u003c\/li\u003e\n\u003cli\u003eSeamless integration with System 1® software and DCS\/PLC via Modbus or OPC.\u003c\/li\u003e\n\u003cli\u003eExtended temperature range and conformal coating options for harsh environments.\u003c\/li\u003e\n\u003cli\u003eBackward compatible with existing 3500 racks while offering faster Ethernet throughput.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e How to verify correct Ethernet communication after installation?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e Ping the assigned IP from the engineering workstation. Check link LED status on both the I\/O module and switch. If using fiber, verify light levels with a power meter – should read between -20 and -14 dBm for multimode.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e What is the proper grounding procedure for the I\/O module?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Connect the rear slot ground lug directly to the rack's earth ground bus. Use 4 mm² (AWG 11) stranded wire. Ensure the Ethernet cable shield is grounded only at the switch end to avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e Battery replacement steps without losing configuration?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Keep the 3500 rack powered during battery swap. Locate the 3V lithium coin cell on the TDI board. Remove old cell and insert new within 2 minutes – the supercapacitor holds memory for up to 30 minutes. Re-initialize time\/date after replacement.\u003c\/p\u003e\n\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca style=\"color: #0056b3; text-decoration: none; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" style=\"display: inline-block; background-color: #0056b3; color: #ffffff; padding: 10px 20px; text-decoration: none; border-radius: 4px; font-weight: bold;\" target=\"_blank\"\u003eDownload Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899562116,"sku":"3500\/22-01-03-00","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22-01-03-00.jpg?v=1783848702"},{"product_id":"3500-22m-bently-nevada-tdi-module-transient-data-interface","title":"3500\/22M Bently Nevada TDI Module - Transient Data Interface","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eBently Nevada 3500\/22M Transient Data Interface Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22M TDI Module\u003c\/b\u003e delivers high-speed transient data capture for critical turbomachinery. It captures waveform snapshots and event-triggered records, enabling advanced diagnostics for gas turbines, compressors, and steam turbines. This module serves as the communication gateway between the 3500 rack and plant management systems, ensuring continuous monitoring and predictive maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eOrdering Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22M\u003c\/b\u003e part number defines I\/O and approval options. Each digit specifies a critical feature:\u003c\/p\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eI\/O Type (Digit 1):\u003c\/b\u003e 01 = 10Base-T\/100Base-TX Ethernet, 02 = 100Base-FX Fiber Optic, 03 = Ethernet with gold-plated OK relay, 04 = Fiber with gold-plated OK relay.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eAgency Approval (Digit 2):\u003c\/b\u003e 00 = None, 01 = CSA\/NRTL\/C (Class 1 Div 2), 02 = Multi (CSA, ATEX, IECEx).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModule Dimensions (TDI)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTDI Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Powered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e38 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Unpowered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eInstall the TDI module in a full-height front slot; the matching I\/O module occupies one full-height rear slot.\u003c\/li\u003e\n\u003cli\u003eUse twisted-pair shielded cables for Ethernet connections; maintain a minimum bend radius of 10x cable diameter.\u003c\/li\u003e\n\u003cli\u003eFor fiber optic variants (100Base-FX), clean connectors with lint-free wipes and inspect for \u0026lt; 0.5 dB loss.\u003c\/li\u003e\n\u003cli\u003eWhen replacing a legacy 3500\/22, ensure the firmware revision is updated to support the new I\/O options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 3500\/22M\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eProvides buffered transient data for post-event analysis and predictive trending.\u003c\/li\u003e\n\u003cli\u003eSeamless integration with System 1® software and DCS\/PLC via Modbus or OPC.\u003c\/li\u003e\n\u003cli\u003eExtended temperature range and conformal coating options for harsh environments.\u003c\/li\u003e\n\u003cli\u003eBackward compatible with existing 3500 racks while offering faster Ethernet throughput.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e How to verify correct Ethernet communication after installation?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e Ping the assigned IP from the engineering workstation. Check link LED status on both the I\/O module and switch. If using fiber, verify light levels with a power meter – should read between -20 and -14 dBm for multimode.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e What is the proper grounding procedure for the I\/O module?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Connect the rear slot ground lug directly to the rack's earth ground bus. Use 4 mm² (AWG 11) stranded wire. Ensure the Ethernet cable shield is grounded only at the switch end to avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e Battery replacement steps without losing configuration?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Keep the 3500 rack powered during battery swap. Locate the 3V lithium coin cell on the TDI board. Remove old cell and insert new within 2 minutes – the supercapacitor holds memory for up to 30 minutes. Re-initialize time\/date after replacement.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899594884,"sku":"3500\/22M","price":562.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500-22m.jpg?v=1783832462"},{"product_id":"3500-22m-01-01-r0-tdi-module-bently-nevada","title":"3500\/22M-01-01-R0 TDI Module - Bently Nevada","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/22M-01-01-R0 TDI Module\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color:#2c6e9e;\"\u003eBently Nevada 3500\/22M-01-01-R0\u003c\/strong\u003e is a Transient Data Interface (TDI) module for 3500 rack systems. Features standard TDI type with 10Base-T 100Base-TX Ethernet I\/O. Compact design for data monitoring applications. Module weight 0.91 kg.\u003c\/p\u003e\n\n\u003ch3\u003eModel Number Breakdown\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eOption Code\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eDescription\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e01 (A: TDI Type)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eStandard - for standard monitoring applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e01 (B: I\/O Type)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eR0 (C: Agency Approval)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eAgency approval status not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eValue\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e3500\/22M-01-01-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eTDI Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eI\/O Interface\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e10Base-T \/ 100Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e241.3 x 24.4 x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTransient Data Interface for 3500 monitoring systems\u003c\/li\u003e\n\u003cli\u003e10Base-T \/ 100Base-TX Ethernet communication\u003c\/li\u003e\n\u003cli\u003eWide operating temperature -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003eCompact dimensions 241.3 x 24.4 x 241.8 mm\u003c\/li\u003e\n\u003cli\u003e95% humidity tolerance for industrial environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Install TDI module into full-height rear slot of 3500 rack. Secure with mounting screws. Verify backplane connection aligns properly before seating.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Connection:\u003c\/strong\u003e Connect Ethernet cable to RJ45 port on module front face. Use shielded CAT5e or CAT6 cable for reliable communication. Verify network switch port matches 10\/100Base-TX speed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Ensure rack ground connection to plant earth. TDI module requires proper backplane grounding through rack. No separate ground wire needed.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What Ethernet interface does 3500\/22M provide?\u003c\/strong\u003e\u003cbr\u003eA1: 10Base-T and 100Base-TX Ethernet. Auto-negotiation supported for speed and duplex.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the module dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eA2: 241.3 x 24.4 x 241.8 mm. Weight 0.91 kg (2.0 lbs).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA3: -30°C to +65°C (-22°F to +149°F). Storage -40°C to +85°C.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899660420,"sku":"3500\/22M-01-01-R0","price":412.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22M-01-01-R0.jpg?v=1783850420"},{"product_id":"bently-nevada-3500-25-01-03-02-enhanced-keyphasor-module","title":"Bently Nevada 3500\/25-01-03-02 Enhanced Keyphasor Module","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eBently Nevada 3500\/25-01-03-02 Enhanced Keyphasor Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/25-01-03-02 Enhanced Keyphasor Module\u003c\/b\u003e provides precise reference signals for speed and phase measurement in turbomachinery. It delivers reliable Keyphasor pulses to the monitoring system, enabling accurate synchronous sampling and diagnostics for gas turbines, steam turbines, and compressors. This module is ATEX\/IECEx certified for hazardous area installations.\u003c\/p\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eOrdering Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/25-01-03-02\u003c\/b\u003e part number follows this structure: \u003cb style=\"color: #0056b3;\"\u003e3500\/25-AA-BB-CC\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eAA – Channel Configuration:\u003c\/b\u003e 01 = Single half-height 2-channel Keyphasor card (option for 2 channels)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eBB – I\/O Module Type:\u003c\/b\u003e 03 = Internal Barrier I\/O with Internal Terminations\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eCC – Agency Approval:\u003c\/b\u003e 02 = ATEX\/IECEx\/CSA (Class 1 Zone 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/25-01-03-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eChannel Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSingle half-height 2-channel Keyphasor card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInternal Barrier I\/O with Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eATEX\/IECEx\/CSA (Class 1 Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMain Module Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e119.9 x 24.4 x 256.5 mm (4.72 x 0.96 x 10.10 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMain Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.34 kg (0.76 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 103.1 mm (9.50 x 0.96 x 4.06 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.46 kg (1.01 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature (Standard I\/O)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature (Internal Barrier I\/O)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0°C to +65°C (32°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eInstall the Keyphasor module in any half-height front slot of the 3500 rack. The I\/O module occupies the corresponding rear slot.\u003c\/li\u003e\n\u003cli\u003eFor Internal Barrier I\/O, observe the reduced operating temperature range of 0°C to +65°C. Ensure adequate cabinet cooling.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cables for Keyphasor signal wiring. Maintain a minimum bend radius of 10x cable diameter.\u003c\/li\u003e\n\u003cli\u003eIn hazardous area installations (ATEX\/IECEx), ensure proper cable glands and sealing per local certification requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 3500\/25-01-03-02\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eProvides precise Keyphasor pulses for accurate speed and phase measurement.\u003c\/li\u003e\n\u003cli\u003eInternal Barrier I\/O eliminates the need for external safety barriers in hazardous areas.\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx\/CSA certification allows installation in Class 1 Zone 2 environments.\u003c\/li\u003e\n\u003cli\u003eCompact half-height design saves rack space while delivering 2-channel capability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e What is the difference between standard I\/O and Internal Barrier I\/O?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e Internal Barrier I\/O includes built-in galvanic isolation and zener barriers for hazardous area installations. This eliminates the need for external safety barriers but reduces the operating temperature range to 0°C to +65°C.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e How many Keyphasor channels does this module provide?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e The 3500\/25-01-03-02 provides 2 Keyphasor channels on a single half-height card. Each channel accepts a proximity probe or magnetic pickup input.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e What is the recommended sensor type for Keyphasor input?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Bently Nevada recommends 3300 XL 8mm proximity probes or magnetic pickups with a voltage output between -0.8V and -21V DC. Ensure the sensor is properly gapped per the installation manual.\u003c\/p\u003e\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #0056b3; text-decoration: none; font-weight: bold;\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899955332,"sku":"3500\/25-01-03-02","price":298.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_25-01-03-02-2.jpg?v=1783863663"},{"product_id":"bently-nevada-3500-33-01-01-16-channel-relay-module","title":"Bently Nevada 3500\/33-01-01 16-Channel Relay Module","description":"\u003ch2\u003eBently Nevada 3500\/33-01-01 16-Channel Relay Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eBently Nevada 3500\/33-01-01\u003c\/strong\u003e 3500\/33 16-Channel Relay Output Module. Provides 16 independent SPDT relay outputs for machinery protection systems. Epoxy-sealed relays with arc suppressors ensure reliable operation in demanding industrial environments. cNRTLus certified for Class I Division 2 hazardous areas.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e16 SPDT relay outputs. Epoxy-sealed environmental sealing. 250 Vrms arc suppressor standard. Four groups of four channels with switch-selectable Normally De-energized (ND) or Normally Energized (NE) operation. Front panel OK, TX\/RX, and CH Alarm LEDs. 5.8W typical power consumption. Main module 0.7 kg, I\/O module 0.4 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3500\/33-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3500\/33 16-Channel Relay Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Module (A)\u003c\/td\u003e\n\u003ctd\u003e01 = 16-Channel Relay Output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApproval Option (B)\u003c\/td\u003e\n\u003ctd\u003e01 = cNRTLus (Class I Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Type\u003c\/td\u003e\n\u003ctd\u003eSingle-pole Double-throw (SPDT)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Sealing\u003c\/td\u003e\n\u003ctd\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd\u003e250 Vrms (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Life\u003c\/td\u003e\n\u003ctd\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Operation\u003c\/td\u003e\n\u003ctd\u003e4 groups of 4, switch-selectable ND\/NE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.4 kg (1.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (Main)\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (I\/O)\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eContact Ratings\u003c\/h3\u003e\n\u003ch4\u003eStandard Relays\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd\u003e70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd\u003e1200 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eFailsafe \/ Hazardous Area Systems\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Voltage\u003c\/td\u003e\n\u003ctd\u003e30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch4\u003eLow Current Applications\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd\u003e1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Switched Current\u003c\/td\u003e\n\u003ctd\u003e100 mA @ 48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33-01-01\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e – 16-Channel Relay Module.\u003cbr\u003e\u003cstrong\u003eA:01\u003c\/strong\u003e – 16-Channel Relay Output Module.\u003cbr\u003e\u003cstrong\u003eB:01\u003c\/strong\u003e – cNRTLus (Class I Division 2) hazardous area approval.\u003c\/p\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall main module in full-height front slot. Install I\/O module in corresponding rear slot. Configure relay groups for ND or NE operation via switches. Observe contact rating limits for standard, failsafe, or low current applications. Ensure proper grounding per Bently Nevada guidelines.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003e16 independent relay outputs provide flexible alarm and control signaling. Epoxy-sealed relays withstand harsh industrial environments. Arc suppressors extend contact life and reduce EMI. cNRTLus certification enables installation in Class I Division 2 hazardous areas. Switch-selectable ND\/NE per group simplifies integration with existing control schemes.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many relay outputs does this module provide?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 16 independent SPDT relay outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What are the contact ratings for standard applications?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 5A max, 125Vdc or 250Vac, 70W @ 24Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the relay operation configuration?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Four groups of four channels, switch-selectable for Normally De-energized or Normally Energized operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047900053636,"sku":"3500\/33-01-01","price":286.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-01.jpg?v=1787491741"},{"product_id":"3500-33-01-r0-bently-nevada-relay-output-module","title":"3500\/33-01-R0 Bently Nevada Relay Output Module","description":"\u003ch2\u003eBently Nevada 3500\/33-01-R0 16-Channel Relay Module\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eBently Nevada 3500\/33-01-R0\u003c\/strong\u003e is a full-height 16-Channel Relay Module for 3500 rack systems. Each output can be independently programmed with alarm drive logic using AND\/OR logic and voting based on alarming inputs, Not-OK signals, and measured variables from any monitor channel.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e 3500\/33-01-R0\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 16-Channel Relay Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Position:\u003c\/strong\u003e Any slot to the right of TDI Module\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel Number Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33 AA-BB\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e – 16-Channel Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR0\u003c\/strong\u003e – Hazardous Area Approval: cNRTLus (Class 1, Division 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 mm (9.50 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e24.4 mm (0.96 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e242 mm (9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eSPDT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e125 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e250 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eHazardous Area Approval\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ecNRTLus (Class 1, Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAlarm Drive Logic\u003c\/h3\u003e\n\u003cp\u003eEach relay includes programmable alarm drive logic using AND and OR logic, incorporating:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlarming inputs (alert and danger statuses)\u003c\/li\u003e\n\u003cli\u003eNot-OK signals\u003c\/li\u003e\n\u003cli\u003eIndividual measured variables from any monitor channel or combination\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInstall in any full-height slot to the right of TDI Module.\u003c\/li\u003e\n\u003cli\u003eEach relay channel can be independently programmed.\u003c\/li\u003e\n\u003cli\u003eFour groups of four channels available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What does R0 indicate in the model number?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e R0 indicates cNRTLus hazardous area approval for Class 1, Division 2 locations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Can each relay be programmed independently?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. Each of the 16 relay outputs has independent alarm drive logic programming.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Where can this module be installed in the rack?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Any full-height slot to the right of the Transient Data Interface (TDI) Module.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047900086404,"sku":"3500\/33-01-R0","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-R0.jpg?v=1784470506"},{"product_id":"bently-nevada-3500-42-06-01-internal-barrier-i-o-4-channel","title":"Bently Nevada 3500\/42-06-01 Shingen Ciki I\/O Tashoshi 4","description":"\u003ch2\u003eTakaitaccen Bayanin Samfur\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cstrong style=\"color: #003366;\"\u003eBently Nevada 3500\/42-06-01\u003c\/strong\u003e na’ura ce ta ƙwararru mai tashoshi 4 irin Proximitor Seismic Monitor da aka ƙera don ci gaba da kare manyan injinan juyawa masu muhimmanci. Wannan module ɗin yana ba da ci-gaba wajen gyaran sigina na transducer \u003cstrong\u003eVelomitor\u003c\/strong\u003e, yana tabbatar da daidaitaccen saka idon girgiza (vibration) da kuma amsa ta atomatik ga ƙararrawa. Tare da \u003cstrong\u003ecikakkun matattarar tsaro na ciki (internal intrinsic safety barriers)\u003c\/strong\u003e, yana ba da damar haɗa na’urori kai tsaye a muhallan da ke da haɗari, yana rage rikitarwar kayan aiki yayin da yake ci gaba da kiyaye mafi ƙa’idojin tsaro na masana’antu ga 3500 Machinery Protection System.\n\u003c\/p\u003e\n\n\u003ch2\u003eSaitin Fasaha\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBabban Module:\u003c\/strong\u003e 3500\/42M Proximitor Seismic Monitor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLambar I\/O Module (-06):\u003c\/strong\u003e I\/O Module mai Internal Barriers \u0026amp; Internal Terminations (musamman don 4 x Velomitor)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAmincewar Hukuma (-01):\u003c\/strong\u003e CSA\/NRTL\/C Certified (Class 1, Division 2, Groups A, B, C, D)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSana’anta:\u003c\/strong\u003e An ƙera shi a U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eƘayyadaddun Fasaha\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eSiffa\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eƘayyadaddun bayanai\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e\u003cstrong\u003eShigar Siginoli\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eSiginoli 1 zuwa 4 na Velomitor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e\u003cstrong\u003eAmfanin Wuta\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e7.7 Watts na yau da kullum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e\u003cstrong\u003eFitowar Recorder\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e4 zuwa 20 mA DC (kowanne tashar dabam)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e\u003cstrong\u003eDaidaito\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e±0.33% na cikakken ma’auni na yau da kullum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e\u003cstrong\u003eAmsar Mitar (Frequency Response)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e3 Hz zuwa 5.5 kHz (-3 dB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e\u003cstrong\u003eInput Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e10 kΩ\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eJagorar Shigarwa \u0026amp; Kula da Na’ura\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cstrong\u003eBuƙatun Haɗa Ƙasa (Grounding):\u003c\/strong\u003e Haɗaɗɗen tsarin barrier a cikin -06 I\/O module yana buƙatar haɗin ƙasa na kayan auna mai inganci sosai. Tabbatar an haɗa rack ɗin 3500 da ƙasa yadda ya kamata domin da’irar intrinsic safety ta yi aiki daidai kuma a kawar da hayaniyar sigina.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cstrong\u003eGwajin Ganowa (Diagnostic Testing):\u003c\/strong\u003e Yi amfani da front-panel coaxial connectors don samun damar buffered transducer outputs. Wannan yana ba da damar nazarin girgiza (vibration) a lokaci guda ta amfani da na’urorin tattara bayanai masu ɗaukuwa ba tare da katse tsarin kariyar injin na monitor ba.\n\u003c\/p\u003e\n\n\u003ch2\u003eFa’idodin Injiniya\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTsaro Mai Haɗe:\u003c\/strong\u003e Barriers na ciki suna kawar da buƙatar Zener barriers na waje, suna rage sararin kabad da kuɗin wayoyi sosai.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDaidaitattun Ganowa:\u003c\/strong\u003e Tacewa mai matakai 4 (4-pole filtering) da ta ci gaba tana ware matsalolin injina daga hayaniyar masana’antu mai mita mai yawa.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eShirye ga Kamfani:\u003c\/strong\u003e Yana sadarwa ba tare da tangarda ba da software ɗin Bently Nevada System 1 don dabarun kulawa bisa yanayi (condition-based maintenance) da ake yi tun kafin matsala ta bayyana.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTambayoyin Fasaha (FAQs)\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Shin wannan module na aiki da standard proximity probes?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: A’a. Saitin \u003cstrong style=\"color: #003366;\"\u003e3500\/42-06-01\u003c\/strong\u003e an fi daidaita shi ne musamman don na’urorin auna saurin girgiza \u003cstrong\u003eVelomitor\u003c\/strong\u003e (velocity sensors). Proximity probes suna buƙatar wani irin I\/O module dabam.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Menene fa’ida ta zaɓin -06 Internal Barrier?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yana ba da kariyar intrinsic safety a cikin module ɗin kansa, yana ba da damar shigarwa mai ƙanƙantar wuri kuma mai sauƙi lokacin saka idon na’urori da ke cikin muhallan da ke da haɗari.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Zan iya cire wannan module in maye gurbinsa yayin da tsarin ke kunne (hot-swap)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: I, jerin 3500 na tallafawa hot-swapping. Duk da haka, tabbatar an saka rack ɗin a yanayin \"Configuration\" ko \"Service\" domin hana tashi ba gaira ba dalili yayin musayar module.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047900414084,"sku":"3500\/42-06-01","price":366.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_42-06-01.jpg?v=1777811034"},{"product_id":"bently-nevada-3500-60-01-r0-temperature-monitor-7w","title":"Bently Nevada 3500\/60-01-R0 Temperature Monitor 7W","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/60-01-R0 Temperature Monitor Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 3500\/60-01-R0\u003c\/strong\u003e is a temperature monitor module with RTD\/TC non-isolated I\/O module and internal terminations. Features 7W nominal power consumption, 0.91kg weight, and seamless 3500 system integration.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e3500\/60-01-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eTemperature Monitor Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eI\/O Module Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e01 = RTD\/TC Non-isolated, Internal Terminations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e7W nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0.91 kg (2.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eDimensions\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHeight x Width x Depth\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e241.3 x 24.4 x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInches\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e9.50 x 0.96 x 9.52 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eRTD\/TC non-isolated I\/O module with internal terminations\u003c\/li\u003e\n\u003cli\u003eFully certified for global standards\u003c\/li\u003e\n\u003cli\u003eSeamless integration within 3500 monitoring system\u003c\/li\u003e\n\u003cli\u003eExpandable with supplementary modules for custom needs\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the I\/O module type?\u003c\/strong\u003e\u003cbr\u003eA1: 01 = RTD\/TC Non-isolated I\/O Module with internal terminations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the power consumption?\u003c\/strong\u003e\u003cbr\u003eA2: 7W nominal.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the weight of the module?\u003c\/strong\u003e\u003cbr\u003eA3: 0.91 kg (2.0 lb).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047901233284,"sku":"3500\/60-01-R0","price":274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_60-01-R0.jpg?v=1787486271"},{"product_id":"bently-nevada-136180-01-3500-92-communication-gateway","title":"Bently Nevada 136180-01 | Kofar Sadarwa 3500\/92","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 136180-01 Na’urar Kofa ta Sadarwa (Communication Gateway Module)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMarubuci: Etowon Auto\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 136180-01\u003c\/strong\u003e na ba da aikin kofa ta sadarwa. Wannan na’urar jerin 3500 tana ba da damar musayar bayanai tsakanin tsarin saka idanu da hanyoyin sadarwa. Yana karɓar bayanan na’urorin da ke cikin rack da saurin sabunta bayanai.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eƘayyadaddun Fasaha\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlama \u0026amp; Samfuri:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #d32f2f;\"\u003e136180-01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJeri:\u003c\/strong\u003e 3500 Series Communication Gateway\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNau’in Samfuri:\u003c\/strong\u003e 3500\/92 Gateway Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmfanin Wuta:\u003c\/strong\u003e 5.0W (RS232\/422), 5.6W (RS485)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLokacin Sabunta Bayanai:\u003c\/strong\u003e ≤1 daƙiƙa ga dukkan na’urorin rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSaurin Ethernet:\u003c\/strong\u003e 10Mbps mai jituwa da IEEE802.3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTsari (Protocol):\u003c\/strong\u003e Sadarwar Modbus\/TCP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMai Haɗawa:\u003c\/strong\u003e RJ-45 10BASE-T Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNauyi:\u003c\/strong\u003e 0.82 kg (1.8 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGirma:\u003c\/strong\u003e 241 × 24.4 × 242 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRamin Rack:\u003c\/strong\u003e Rami ɗaya na gaba mai cikakken tsayi (full-height front slot)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFasalolin Tattara Bayanai\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eYana karɓar ƙimar yanzu daga na’urori\u003c\/li\u003e\n\u003cli\u003eYana tattara bayanan matsayi da ƙararrawa\u003c\/li\u003e\n\u003cli\u003eYana saka idon dukkan na’urorin rack na 3500\u003c\/li\u003e\n\u003cli\u003eYana ba da sabunta bayanai a ainihin lokaci (real-time)\u003c\/li\u003e\n\u003cli\u003eYana tallafawa nau’o’in I\/O da dama\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAlamomin LED\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLED na OK - Nuna matsayin aiki\u003c\/li\u003e\n\u003cli\u003eLED na TX\/RX - Ayyukan sadarwa\u003c\/li\u003e\n\u003cli\u003eBayyanannen sa ido na matsayi ta gani\u003c\/li\u003e\n\u003cli\u003eGaggawar gano matsala\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eMahimman Fasali\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSaurin sabunta bayanai ≤1 daƙiƙa\u003c\/li\u003e\n\u003cli\u003eƘananan amfani da wuta 5.0W\u003c\/li\u003e\n\u003cli\u003eSadarwar Ethernet 10Mbps\u003c\/li\u003e\n\u003cli\u003eZane mai sauƙin nauyi 0.82kg\u003c\/li\u003e\n\u003cli\u003eTallafin tsari na Modbus\/TCP\u003c\/li\u003e\n\u003cli\u003eHaɗin RJ-45 na ƙa’ida\u003c\/li\u003e\n\u003cli\u003eShigarwa a rack mai cikakken tsayi\u003c\/li\u003e\n\u003cli\u003eSaka idon matsayi a ainihin lokaci\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAbubuwan da ke Cikin Kunshi\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eNa’ura guda ɗaya \u003cstrong\u003eBently Nevada 136180-01\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eKayan ɗaurewa a rack\u003c\/li\u003e\n\u003cli\u003eTakrurin shigarwa\u003c\/li\u003e\n\u003cli\u003eƘayyadaddun fasaha\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBayanin Jigila\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eJigilar FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eSarrafa oda cikin kwanaki 2-5 na aiki\u003c\/li\u003e\n\u003cli\u003eAkwai isarwa zuwa ƙasashe daban-daban (international)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJagorar Shigarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA saka a ramin gaba na rack ɗin 3500\u003c\/li\u003e\n\u003cli\u003eA haɗa kebul na RJ-45 Ethernet\u003c\/li\u003e\n\u003cli\u003eA saita saitunan Modbus\/TCP\u003c\/li\u003e\n\u003cli\u003eA saita sigogin tattara bayanai\u003c\/li\u003e\n\u003cli\u003eA gwada ayyukan alamomin LED\u003c\/li\u003e\n\u003cli\u003eA tabbatar da ingancin saurin sabunta bayanai\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eƘayyadaddun Sadarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEthernet: 10Mbps 10BASE-T\u003c\/li\u003e\n\u003cli\u003eTsari (Protocol): Modbus\/TCP standard\u003c\/li\u003e\n\u003cli\u003eSerial: Taimakon RS232\/422\/485\u003c\/li\u003e\n\u003cli\u003eRate ɗin Sabuntawa: ≤1 daƙiƙa\u003c\/li\u003e\n\u003cli\u003eNau’o’in Bayanai: Ƙimomi, matsayi, ƙararrawa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTambayoyi da Ake Yawan Yi (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene saurin sabuntawa?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e ≤1 daƙiƙa ga dukkan bayanan na’urorin rack.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene nauyin na’urar?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 0.82 kg (1.8 pounds).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Wane irin saurin Ethernet ake da shi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 10Mbps mai jituwa da IEEE802.3.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTuntuɓa \u0026amp; Albarkatu\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eImel: sale@etowonauto.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-92.pdf?v=1741074790\" target=\"_blank\"\u003eZazzage Takaddar Ƙayyadaddun Fasaha (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047901397124,"sku":"136180-01","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/136180-01.jpg?v=1769913334"},{"product_id":"bently-nevada-3500-92-04-01-01-communication-gateway-module","title":"Bently Nevada 3500\/92-04-01-01 | Kundin Kofar Sadarwa","description":"\u003ch2\u003e\u003cstrong\u003eKofar Sadarwa ta Bently Nevada 3500\/92-04-01-01\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMarubuci: Etowon Auto\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/92-04-01-01\u003c\/strong\u003e yana ba da ayyukan kofar sadarwa na masana’antu. Wannan na’ura tana haɗa na’urorin filin aiki da tsarin kulawa cikin sauƙi.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTakardun Fasaha\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlamar Kamfani \u0026amp; Samfuri:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #d32f2f;\"\u003e3500\/92-04-01-01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNau’in Katin I\/O:\u003c\/strong\u003e 04 - Ethernet\/RS485 Modbus\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNau’in Ƙwaƙwalwa:\u003c\/strong\u003e 01 - Tsarin ƙwaƙwalwa mai ƙaranci\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmincewa:\u003c\/strong\u003e 01 - Takaddar CSA\/NRTL\/C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNauyi:\u003c\/strong\u003e 0.82 kg (1.8 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGirma:\u003c\/strong\u003e 241 × 24.4 × 242 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZafin Aiki:\u003c\/strong\u003e -30°C zuwa +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZafin Ajiya:\u003c\/strong\u003e -40°C zuwa +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZafi a Iska:\u003c\/strong\u003e 95% ba tare da tara danshi ba\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eSiffofin Sadarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHaɗin cibiyar sadarwar Ethernet\u003c\/li\u003e\n\u003cli\u003eSadarwar serial ta RS485 Modbus\u003c\/li\u003e\n\u003cli\u003eGoiyon bayan ladubban sadarwa na masana’antu\u003c\/li\u003e\n\u003cli\u003eƘarfin aika bayanai cikin tsaro\u003c\/li\u003e\n\u003cli\u003eAyyukan da ke ba da damar na’urori su yi aiki tare\u003c\/li\u003e\n\u003cli\u003eTsarin ƙira mai jure kuskure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManyan Fasali\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSadarwa ta Ethernet\/RS485 biyu\u003c\/li\u003e\n\u003cli\u003eTsarin ƙira mai ɗan nauyi 0.82 kg\u003c\/li\u003e\n\u003cli\u003eFaɗaɗɗen zangon zafi -30°C zuwa +65°C\u003c\/li\u003e\n\u003cli\u003eTakaddar tsaro ta CSA\/NRTL\/C\u003c\/li\u003e\n\u003cli\u003eƘarfin aiki a zafin zafi na 95%\u003c\/li\u003e\n\u003cli\u003eGinuwar masana’antu mai ƙarfi\u003c\/li\u003e\n\u003cli\u003eHaɗa bayanai cikin aminci\u003c\/li\u003e\n\u003cli\u003eSauƙin haɗawa cikin tsarin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAbubuwan Cikin Kunshi\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eƊaya \u003cstrong\u003e3500\/92-04-01-01\u003c\/strong\u003e na’urar gateway\u003c\/li\u003e\n\u003cli\u003eƘunshin kayan makalawa\u003c\/li\u003e\n\u003cli\u003eTakrdirin shigarwa\u003c\/li\u003e\n\u003cli\u003eTakardun takaddar inganci\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBayanan Jirgi\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAkwai jigila ta FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eTsarin aiki na kwanakin kasuwanci 2-5\u003c\/li\u003e\n\u003cli\u003eGoiyon bayan jigilar ƙasashen waje\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJagorar Shigarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eA saka cikin chassis na jerin 3500\u003c\/li\u003e\n\u003cli\u003eA haɗa kebul na cibiyar sadarwar Ethernet\u003c\/li\u003e\n\u003cli\u003eA yi wayoyi na haɗin RS485 Modbus\u003c\/li\u003e\n\u003cli\u003eA daidaita ladubban sadarwa\u003c\/li\u003e\n\u003cli\u003eA saita taswirar bayanai (data mapping)\u003c\/li\u003e\n\u003cli\u003eA gwada aikin gateway\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTambayoyi Masu Yawan Yuwa (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eT: Menene ma’anar 04-01-01?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Saiti: Ethernet\/RS485, ƙwaƙwalwa mai ƙaranci, amincewar CSA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eT: Nawa ne nauyin wannan na’ura?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 0.82 kg (1.8 pounds).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eT: Wane zangon zafi take iya aiki?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Aiki daga -30°C zuwa +65°C.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTuntuɓa \u0026amp; Albarkatu\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eImel: sale@etowonauto.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-92.pdf?v=1741074790\" target=\"_blank\"\u003eZazzage Takardun Bayanai na PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047901429892,"sku":"3500\/92-04-01-01","price":149.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_92-04-01-01.jpg?v=1769912939"},{"product_id":"bently-nevada-3500-93-02-00-00-00-rack-mount-display-module","title":"Bently Nevada 3500\/93-02-00-00-00 | Kundin Nuni na Dutsen Rack","description":"\u003ch2\u003e\u003cstrong\u003eModule Ɗin Nuni na Musaya Bently Nevada 3500\/93-02-00-00-00\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMarubuci: Etowon Auto\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/93-02-00-00-00\u003c\/strong\u003e yana samar da haɗin nuni na musaya (display interface). Wannan module da aka daidaita yana bayar da damar hawa a jikin 19\" EIA rack. Yana tallafawa tsarin sa ido na masana’antu tare da ingantaccen aiki mai ɗorewa.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eƘayyadaddun Fasaha\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlamar kasuwa \u0026amp; Samfuri:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #d32f2f;\"\u003e3500\/93-02-00-00-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSaituwa (Configuration):\u003c\/strong\u003e tsarin 02-00-00-00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHawa (Mounting):\u003c\/strong\u003e 19\" EIA Standard Rack\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFaɗi (Width):\u003c\/strong\u003e ƙirar da aka inganta 24.4 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZaɓin kebul:\u003c\/strong\u003e shigarwa ba tare da kebul ba na 0-30m\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShigar wutar lantarki:\u003c\/strong\u003e aiki na 24 VDC ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMai jituwa da AC:\u003c\/strong\u003e kewayon shigar 90-264 VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNauyi:\u003c\/strong\u003e 0.38 kg (0.84 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGirman:\u003c\/strong\u003e 241.3 × 24.4 × 99.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZafin aiki:\u003c\/strong\u003e -20°C zuwa +70°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCikakkun Bayanan Saituwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA=02:\u003c\/strong\u003e shigarwa a 19\" EIA Rack Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB=00:\u003c\/strong\u003e ba a buƙatar kebul (0-30m)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC=00:\u003c\/strong\u003e tushen wuta 24VDC ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD=00:\u003c\/strong\u003e daidaitawa da ƙa’idojin CE\/RoHS na daidaitaccen mataki\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eƘayyadaddun Ayyuka\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eYawan bayanai (Data Rate):\u003c\/strong\u003e 100 Mbps throughput na Ethernet\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e dogaro na awanni 100,000\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcessor:\u003c\/strong\u003e 32-bit RISC don aiki a ainihin-lokaci (real-time)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKa’idojin sadarwa (Protocols):\u003c\/strong\u003e Modbus RTU\/TCP, OPC UA\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKariya:\u003c\/strong\u003e matakin IP40 tare da shafi (coating)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHaƙurin wuta:\u003c\/strong\u003e karɓar ƙarfin lantarki na ±5%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGaranti:\u003c\/strong\u003e cewaftin (limited) na watanni 36\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eManyan Fasali\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDaidaitaccen hawa a 19\" EIA rack\u003c\/li\u003e\n\u003cli\u003eƘira mai taushi 0.38kg wadda ba ta da nauyi\u003c\/li\u003e\n\u003cli\u003eFaɗaɗɗen zangon zafin aiki -20°C zuwa +70°C\u003c\/li\u003e\n\u003cli\u003eShigar wuta mai sassauci 24VDC ±10%\u003c\/li\u003e\n\u003cli\u003eSadarwar Ethernet mai sauri 100 Mbps\u003c\/li\u003e\n\u003cli\u003eDogon MTBF na awanni 100,000 na dogaro\u003c\/li\u003e\n\u003cli\u003eShigarwa ba tare da kebul ba har zuwa 30m\u003c\/li\u003e\n\u003cli\u003eKariya ta garanti na watanni 36\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAbubuwan Cikin Kunshi\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eƊaya \u003cstrong\u003e3500\/93-02-00-00-00\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eKayan aiki na hawa a rack\u003c\/li\u003e\n\u003cli\u003eJagorar shigarwa\u003c\/li\u003e\n\u003cli\u003eTakaran bayanin garanti\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBayanan Jirgi (Shipping)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx, UPS, DHL suna samuwa\u003c\/li\u003e\n\u003cli\u003eLokacin sarrafawa na kwanakin aiki 2-5\u003c\/li\u003e\n\u003cli\u003eZaɓuɓɓukan jigilar kaya na ƙasashen waje\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJagorar Shigarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShigar da shi a cikin 19\" EIA standard rack\u003c\/li\u003e\n\u003cli\u003eHaɗa tushen wutar 24VDC\u003c\/li\u003e\n\u003cli\u003eDaidaita 90-264VAC idan an buƙata\u003c\/li\u003e\n\u003cli\u003eSaita haɗin cibiyar sadarwar Ethernet\u003c\/li\u003e\n\u003cli\u003eDaidaita ka’idojin sadarwa (communication protocols)\u003c\/li\u003e\n\u003cli\u003eGwada aikin interface ɗin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJituwa (Compatibility)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTsarin Bently Nevada 3500 series\u003c\/li\u003e\n\u003cli\u003eNuninan sa ido na masana’antu\u003c\/li\u003e\n\u003cli\u003eTsarin SCADA da na kula (control systems)\u003c\/li\u003e\n\u003cli\u003eInterface ɗin nuni na VGA\/HDMI\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTambayoyi da Amsa (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene ma’anar 02-00-00-00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Saituwa: rack mount, babu kebul, 24VDC, daidaitaccen ƙa’ida.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene nauyin?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 0.38 kg (0.84 pounds).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Wane irin tushen wuta ake buƙata?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 24VDC ±10% ko mai jituwa da 90-264VAC.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTuntuɓa \u0026amp; Albarkatu\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eImel: sale@etowonauto.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-93_System_Display.pdf?v=1742952016\" target=\"_blank\"\u003eZazzage cikakken PDF na ƙayyadaddun bayanai\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047901462660,"sku":"3500\/93-02-00-00-00","price":155.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_93-02-00-00-00.jpg?v=1769911583"},{"product_id":"3500-93-05-00-02-00-bently-nevada-tft-display-module","title":"3500\/93-05-00-02-00 | Bently Nevada Kundin Nuni na TFT","description":"\u003ch2\u003e\u003cstrong\u003eNunin Tsarin Bently Nevada 3500\/93-05-00-02-00\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMarubuci: Etowon Auto\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/93-05-00-02-00\u003c\/strong\u003e yana ba da ingantaccen nunin masana’antu. Wannan tsarin yana samar da gani bayyananne don sa ido a aikace-aikacen da suka da muhimmanci. Yana zuwa sabo daga masana’anta an rufe shi gaba ɗaya, tare da garanti na watanni 12.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eƘayyadaddun Fasaha\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlama \u0026amp; Samfuri:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #d32f2f;\"\u003e3500\/93-05-00-02-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNau’in Nuni:\u003c\/strong\u003e LED-backlit TFT panel\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eƘuduri:\u003c\/strong\u003e 1280 × 800 pixels\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHaske:\u003c\/strong\u003e fitarwa 300 cd\/m²\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRatio na Bambanci:\u003c\/strong\u003e 5000:1 babban bambanci\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKusurwar Kallo:\u003c\/strong\u003e 178° faffadan fasahar IPS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShigar Wuta:\u003c\/strong\u003e 230V AC ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eYawan Mitar:\u003c\/strong\u003e aiki 45-65 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZafin Aiki:\u003c\/strong\u003e -20°C zuwa +60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShaidar Inganci:\u003c\/strong\u003e bin ƙa’idar CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eƘayyadaddun Jiki\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNa’urar Nuni:\u003c\/strong\u003e 412.8×203.2×31.2 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNauyin Nuni:\u003c\/strong\u003e 2.1 kg (4.63 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule na Interface:\u003c\/strong\u003e 241.3×24.4×99.1 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNauyin Module:\u003c\/strong\u003e 0.38 kg (0.84 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eZurfin Tsari:\u003c\/strong\u003e 241.8 mm lokacin shigarwa\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJimillar Nauyi:\u003c\/strong\u003e 2.48 kg (5.47 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCikakkun Bayanai na Saitawa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaurin Shigarwa (05):\u003c\/strong\u003e Back-lighted System Face Mount (a daure a fuska tare da haske a baya)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNisa (00):\u003c\/strong\u003e Ba a buƙatar igiyoyi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWuta (02):\u003c\/strong\u003e wutar shigar 230V AC ±10%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAmincewa (00):\u003c\/strong\u003e daidaitacciyar takardar shaidar CE\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuƙatar Rami:\u003c\/strong\u003e module ɗin DIM a rami na 15\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWutar Samarwa:\u003c\/strong\u003e ana buƙatar wutar waje (external PSU)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eMahimman Fasali\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eBabban nuni TFT mai ƙuduri 1280x800\u003c\/li\u003e\n\u003cli\u003eShigarwa nau’in face mount tare da haske a baya\u003c\/li\u003e\n\u003cli\u003eFaɗaɗɗen zangon zafin aiki -20°C zuwa +60°C\u003c\/li\u003e\n\u003cli\u003eNauyin na’urar nuni 2.1kg\u003c\/li\u003e\n\u003cli\u003eNauyin module na interface 0.38kg\u003c\/li\u003e\n\u003cli\u003eShigar wuta 230VAC ±10%\u003c\/li\u003e\n\u003cli\u003eGaranti na watanni 12 daga masana’anta\u003c\/li\u003e\n\u003cli\u003eModule za a iya cirewa kuma a maye gurbinsa yayin aiki (hot-swappable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAbubuwan Da Ke Cikin Kwalin\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSabo daga masana’anta an rufe \u003cstrong\u003e3500\/93-05-00-02-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eNa’urar nuni da module na interface\u003c\/li\u003e\n\u003cli\u003eKit ɗin kayan haɗin daurin shigarwa\u003c\/li\u003e\n\u003cli\u003eTakarar garanti\u003c\/li\u003e\n\u003cli\u003eJagorar shigarwa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJirgi \u0026amp; Garanti\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAkwai jigilar kaya ta FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eLokacin sarrafawa kwanaki 2-5 na aiki\u003c\/li\u003e\n\u003cli\u003eGaranti cikakke na watanni 12\u003c\/li\u003e\n\u003cli\u003eAna haɗa tallafin fasaha\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJagorar Shigarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShigar da module ɗin DIM a ramin tsarin na 15\u003c\/li\u003e\n\u003cli\u003eDaura nunin ta hanyar face mount\u003c\/li\u003e\n\u003cli\u003eHaɗa wutar waje 230VAC\u003c\/li\u003e\n\u003cli\u003eBa a buƙatar ƙarin igiyoyi\u003c\/li\u003e\n\u003cli\u003eGwada nuni da aikin haske na baya\u003c\/li\u003e\n\u003cli\u003eTabbatar da haɗa tsarin gaba ɗaya ya yi daidai\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTambayoyi Masu Yawan Yi (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene 05-00-02-00 ke nufi?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Lambar saitawa ce: face mount, babu igiya, 230VAC, daidaitacciyar CE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene nauyin nunin?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Na’urar nuni tana nauyin 2.1 kg, module na interface 0.38 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Wace irin wutar samarwa ake buƙata?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Na’urar wutar waje 230VAC ±10%.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTuntuɓa \u0026amp; Albarkatu\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eImel: sale@etowonauto.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-93_System_Display.pdf?v=1742952016\" target=\"_blank\"\u003eZazzage PDF na Cikakkun Ƙayyadaddun Fasaha\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047901495428,"sku":"3500\/93-05-00-02-00","price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_93-05-00-02-00-1.jpg?v=1769911418"},{"product_id":"bently-nevada-3500-93-display-module-3500-93-07-01-02-00","title":"Bently Nevada 3500\/93 Sashen Nuni | 3500\/93-07-01-02-00","description":"\u003ch2\u003e\u003cstrong\u003eModule Interface Nuni Bently Nevada 3500\/93-07-01-02-00\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eMawalli: Etowon Auto\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBently Nevada 3500\/93-07-01-02-00\u003c\/strong\u003e yana ba da aikin interface na nuni. Wannan module da aka saita tuni yana ba da yiwuwar daidaita shi a kan panel mai hasken baya (back-lighted panel mounting). Yana zuwa da kebul mai tsawon kafa 10ft da kuma jituwa da wutar 230VAC.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eBayanan Fasaha\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlama \u0026amp; Samfuri:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #d32f2f;\"\u003e3500\/93-07-01-02-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTsari (Configuration):\u003c\/strong\u003e 07-01-02-00 (lambobin A-B-C-D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDaidaita shi:\u003c\/strong\u003e Saka panel mai hasken baya (Back-lighted Panel Mount)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKebul:\u003c\/strong\u003e 10ft\/3m PVC an haɗa shi\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWuta:\u003c\/strong\u003e Shigar 230VAC ±15%\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTakamaiman shaida:\u003c\/strong\u003e Standard CE\/RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eƘuduri (Resolution):\u003c\/strong\u003e Nuni 1280×720\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNauyi:\u003c\/strong\u003e 0.82 kg (1.82 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGirma:\u003c\/strong\u003e 241.3×24.4×241.8 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatsayin IP:\u003c\/strong\u003e Kariyar IP65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCikakkun Bayanai na Tsari (Configuration)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eA=07:\u003c\/strong\u003e Zanen da ake sakawa a kan panel mai hasken baya\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB=01:\u003c\/strong\u003e Kebul PVC mai tsawon 10ft\/3m mai jure hasken UV\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC=02:\u003c\/strong\u003e Ya dace da wadatar wutar 230VAC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD=00:\u003c\/strong\u003e Takardun bin ƙa’idoji na daidaitattun ka’idoji\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eMahimman Fasali\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAn riga an saita shi da tsari 07-01-02-00\u003c\/li\u003e\n\u003cli\u003ePanel mai hasken baya domin ganin nuni a sarari\u003c\/li\u003e\n\u003cli\u003eYa haɗa da kebul 10ft da za a iya amfani da shi nan da nan\u003c\/li\u003e\n\u003cli\u003eShigar 230VAC ±15% mai faɗin zangon shigar wuta\u003c\/li\u003e\n\u003cli\u003eMatsayin IP65 domin yanayin masana’antu\u003c\/li\u003e\n\u003cli\u003eZane mai nauyi 0.82kg kuma ƙarami\u003c\/li\u003e\n\u003cli\u003eNuni mai ƙuduri 1280×720\u003c\/li\u003e\n\u003cli\u003eYana bin ƙa’idojin CE da RoHS\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eAbubuwan da ke Cikin Kunshi\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eƊaya \u003cstrong\u003e3500\/93-07-01-02-00\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eKebul haɗi na PVC 10ft\/3m\u003c\/li\u003e\n\u003cli\u003eBracket na ɗaurewa da bakin karfe (stainless steel)\u003c\/li\u003e\n\u003cli\u003eKusoshi M4 na ɗaurewa (ƙwayoyi 6)\u003c\/li\u003e\n\u003cli\u003eTakardun shigarwa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBayanan Jirgin Kaya\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eJirgin kaya ta FedEx, UPS, DHL\u003c\/li\u003e\n\u003cli\u003eLokacin sarrafa oda: kwanaki 2-5 na aiki\u003c\/li\u003e\n\u003cli\u003eAkwai jigilar kaya zuwa ƙasashe dabam-dabam (international)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eJagorar Shigarwa\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eDaure ta amfani da bracket da aka bayar\u003c\/li\u003e\n\u003cli\u003eHaɗa shi da wadatar wutar 230VAC\u003c\/li\u003e\n\u003cli\u003eHaɗa kebul ɗin 10ft da aka haɗa a cikin kunshi\u003c\/li\u003e\n\u003cli\u003eHaɗa zuwa tsarin sa ido (monitoring system)\u003c\/li\u003e\n\u003cli\u003eGwada aikin hasken baya\u003c\/li\u003e\n\u003cli\u003eTabbatar da aikin nuni\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eBukatun Wuta\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eShigar: 230VAC ±15% (196-264VAC)\u003c\/li\u003e\n\u003cli\u003eMitoci (Frequency): Ya dace da 50\/60Hz\u003c\/li\u003e\n\u003cli\u003eWutar waje: 15W ake buƙata\u003c\/li\u003e\n\u003cli\u003eHaɗi: Kebul na wuta na daidaitaccen salo\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eTambayoyi da Amsoshi (FAQ)\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene ma’anar 07-01-02-00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Lambobin tsari (configuration codes): panel mount, kebul 10ft, 230VAC, daidaitattun takardun shaida.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Ana haɗa kebul ɗin ne?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e I, ana kawo module ɗin tare da kebul PVC 10ft\/3m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Menene nauyin sa?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 0.82 kg (1.82 pounds).\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTuntuɓa \u0026amp; Albarkatu\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eImel: sale@etowonauto.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-93_System_Display.pdf?v=1742952016\" target=\"_blank\"\u003eZazzage PDF na Bayanai na Fasaha\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047901528196,"sku":"3500\/93-07-01-02-00","price":159.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_93-07-01-02-00.jpg?v=1769911172"},{"product_id":"3500-65-01-00-bently-nevada-temperature-module-for-3500-rack","title":"3500\/65-01-00 Bently Nevada Temperature Module for 3500 Rack","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong style=\"color: #0066cc;\"\u003e3500\/65-01-00 145988-02\u003c\/strong\u003e is a 16-channel temperature monitor for critical machinery. It accepts RTD and isolated-tip TC inputs, delivering precise temperature measurement for turbines and compressors. Designed for the 3500 rack, it ensures reliable thermal monitoring in harsh industrial environments.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eI\/O Module Type: 01 – Internal Terminations\u003c\/h3\u003e\n\u003cp\u003e\n  The \u003cstrong\u003e01\u003c\/strong\u003e suffix designates an RTD\/Isolated Tip TC module with internal terminations. This eliminates external termination blocks, reducing wiring complexity. Supports 3-wire\/4-wire RTDs (Pt100, Ni120, Cu10) and TC types E, J, K, T with built-in cold junction compensation.\n\u003c\/p\u003e\n\n\u003ch3\u003eAgency Approval: 00 – None\u003c\/h3\u003e\n\u003cp\u003e\n  Standard version with no additional agency certifications. Complies with FCC, EMC (2014\/30\/EU), LV (2014\/35\/EU), and RoHS (2011\/65\/EU). Meets ABS and DNV GL marine rules without special approvals.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth\u003eParameter\u003c\/th\u003e\n      \u003cth\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Channels\u003c\/td\u003e\n      \u003ctd\u003e1 to 16 RTD or isolated-tip TC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eInput Impedance\u003c\/td\u003e\n      \u003ctd\u003e\u0026gt;1 MΩ per lead\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRTD Types\u003c\/td\u003e\n      \u003ctd\u003e100Ω Pt (α=0.00385 \/ 0.00392), 120Ω Ni, 10Ω Cu\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eTC Types\u003c\/td\u003e\n      \u003ctd\u003eE, J, K, T\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRTD Excitation\u003c\/td\u003e\n      \u003ctd\u003e913 ±7 µA @ 25°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eResolution\u003c\/td\u003e\n      \u003ctd\u003e1°C or 1°F\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAccuracy (Internal Termination)\u003c\/td\u003e\n      \u003ctd\u003e±3°C at +25°C (±5.4°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eCold Junction Compensation\u003c\/td\u003e\n      \u003ctd\u003e±2°C at +25°C (±3.6°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAlarm Setpoints\u003c\/td\u003e\n      \u003ctd\u003e0–100% full-scale, under \u0026amp; over\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eAlarm Delays\u003c\/td\u003e\n      \u003ctd\u003eAlert: 1–60s (1s steps); Danger: 1–60s (0.5s steps)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd\u003e3 W nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eStorage Temperature\u003c\/td\u003e\n      \u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n      \u003ctd\u003e241.3 mm x 24.4 mm x 241.8 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eWeight\u003c\/td\u003e\n      \u003ctd\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd\u003eRack Space\u003c\/td\u003e\n      \u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003ch3\u003eWiring \u0026amp; Termination\u003c\/h3\u003e\n\u003cp\u003e\n  Internal termination eliminates external blocks. Use shielded twisted-pair cables (max 20Ω per lead for RTDs). Keep TC wires away from high-voltage cables and maintain a minimum bending radius of 10x cable diameter.\n\u003c\/p\u003e\n\n\u003ch3\u003eConfiguration\u003c\/h3\u003e\n\u003cp\u003e\n  Configure via 3500 Configuration Software (v3.85+). Set full-scale ranges, alarms, and delays per channel. No manual calibration required. Requires 3500\/22 Firmware Rev 1.50+ and 3500\/93 Rev 2.02+ for proper communication.\n\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eIndustrial Durability\u003c\/h3\u003e\n\u003cp\u003e\n  Operates from -30°C to +65°C and stores at -40°C to +85°C. Galvanically isolated inputs resist ground loops and noise in power plants and process industries.\n\u003c\/p\u003e\n\n\u003ch3\u003eTSI Integration\u003c\/h3\u003e\n\u003cp\u003e\n  Fully compatible with Bently Nevada's 3500 TSI ecosystem. Real-time temperature data acquisition with the same reliability as vibration monitoring modules.\n\u003c\/p\u003e\n\n\u003ch3\u003ePrecision Alarms\u003c\/h3\u003e\n\u003cp\u003e\n  Independent under\/over setpoints per channel. Accuracy within 0.13% of desired value. Programmable delays prevent nuisance trips during transients.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e Can I use external termination blocks with this module?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e No. External blocks are incompatible and will cause an I\/O Module Mismatch error (562 ADC Failure). Use only internal terminations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Which RTD connection is recommended for best accuracy?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 4-wire RTDs provide the highest accuracy. Order with Modification 179952-01 when purchasing I\/O modules for 4-wire use.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What firmware versions are required?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e 3500\/22 Firmware Rev 1.50+, 3500\/93 Rev 2.02+, 3500\/01 Software v3.85+, and System 1 Software Rev 5.2 SP2+. Do not use 3500\/02 or 3500\/03.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050290184324,"sku":"3500\/65-01-00","price":235.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_65-01-00.jpg?v=1787472143"},{"product_id":"bently-nevada-149992-01-relay-module-3500-33","title":"Bently Nevada 149992-01 Relay Module | 3500\/33","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color:#00529b;font-weight:700;\"\u003eBently Nevada 3500\/33-01-CN 149992-01\u003c\/span\u003e is a 16-channel relay module for 3500 rack systems. It provides alarm and trip outputs for turbines, compressors, and pumps in critical machinery protection applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/33\u003c\/strong\u003e – 16-Channel Relay Module.\u003cbr\u003e\n\u003cstrong\u003e-01\u003c\/strong\u003e – Standard 16-Channel Relay Output.\u003cbr\u003e\n\u003cstrong\u003e-CN\u003c\/strong\u003e – Country-specific approvals (China).\u003cbr\u003e\nFour groups of four channels, switch-selectable for Normally De-energized (ND) or Normally Energized (NE) operation.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSPDT, epoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Ratings\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5A @ 250Vac \/ 5A @ 125Vdc (resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMin. Switched Load\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e100mA @ 5Vdc (standard) \/ 1mA @ 1Vdc (gold)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e70W @ 24Vdc, 10W @ 48Vdc, 9W @ 60Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1200VA @ 250Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e250 Vrms (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eOperating Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eStorage Temp.\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eDimensions (HxWxD)\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e241 x 24.4 x 242 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e0.7 kg (1.6 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eRack Space\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eSet each 4-channel group for ND or NE via onboard switches. Use shielded cables for field wiring. For hazardous areas, observe voltage restrictions (30 Vrms max for CSA-only; lower for multiple approvals). Set initial gap voltage to -10 Vdc for standard 3300 XL probes.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eEpoxy-sealed contacts resist dust and corrosion. The module supports SIL-rated safety functions when used with restricted voltage. Seamless integration with 3500 TSI systems and backward-compatible with older 3300 racks (software v3.3+).\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How to check ND vs NE operation?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Measure coil voltage. ND = de-energized in normal state; NE = energized in normal state. Front-panel CH Alarm LED confirms channel status.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What does -CN approval limit?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e The -CN suffix indicates China-specific approvals. It may impose lower maximum voltage limits than standard. Refer to the certificate for exact ratings.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can it replace older 3300\/33 modules?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Yes, with rack configuration v3.3+ and Data Acquisition v2.40+. The module is fully backward-compatible.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050290380932,"sku":"149992-01","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/149992-01.jpg?v=1787408668"},{"product_id":"288055-01-bently-nevada-3500-22-module-transient-data","title":"288055-01 Bently Nevada 3500\/22 Module Transient Data","description":"\u003ch2 style=\"color: #333333;\"\u003eBently Nevada 288055-01 3500\/22 Standard Transient Data Interface Module\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eBently Nevada 288055-01 3500\/22\u003c\/strong\u003e is a standard transient data interface module for the 3500 monitoring system. Includes USB connection cable for easy connectivity. Enables efficient transient data capture and analysis for industrial machinery monitoring applications. Weight: 0.9 kg (2.0 lbs).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e288055-01 \/ 3500\/22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eStandard Transient Data Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eIncluded Accessory\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eUSB connection cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eApplication\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eIndustrial automation and machinery protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOrigin\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e0.9 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eStandard transient data interface for 3500 monitoring systems\u003c\/li\u003e\n\u003cli\u003eUSB connection cable included for easy connectivity\u003c\/li\u003e\n\u003cli\u003eEfficient data capture and analysis for critical machinery\u003c\/li\u003e\n\u003cli\u003eCompatible with 3500 rack architecture\u003c\/li\u003e\n\u003cli\u003eMade in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eUSB Connection:\u003c\/strong\u003e Use the included USB cable to connect the module to a PC. Install Bently Nevada software drivers before connecting. Windows will recognize the module as a serial device.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePower Cycling:\u003c\/strong\u003e Always power down the 3500 rack before inserting or removing the 3500\/22 module. Hot-swapping may damage the backplane connectors.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDriver Installation:\u003c\/strong\u003e Install the Bently Nevada TDXnet software before connecting the USB cable. The driver must be installed first to ensure proper device enumeration.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1. What software is required to use the 3500\/22?\u003c\/strong\u003e\u003cbr\u003e\nA1. The module requires Bently Nevada 3500 System Configuration software and TDXnet software for data acquisition and analysis.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2. Can I use any USB cable with this module?\u003c\/strong\u003e\u003cbr\u003e\nA2. Use the included USB cable or a shielded USB cable of similar quality. Low-quality cables can cause data corruption and connection drops.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3. Does this module support continuous data streaming?\u003c\/strong\u003e\u003cbr\u003e\nA3. Yes. The 3500\/22 supports continuous data streaming for real-time analysis and permanent data capture.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eDownload\u003c\/h3\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" style=\"color: #333333; text-decoration: none; font-weight: bold;\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050360668292,"sku":"3500\/22","price":415.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22.jpg?v=1783852144"},{"product_id":"125565-01-bently-nevada-3500-25-card-guide-half-height","title":"125565-01 Bently Nevada 3500\/25 Card Guide Half Height","description":"\u003ch2\u003e125565-01 Bently Nevada 3500-25 Half Height Module Card Guide\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eBently Nevada 125565-01\u003c\/strong\u003e is a half-height module card guide for the 3500 System Rack. Secures and aligns monitor modules for proper backplane connectivity.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e125565-01\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eHalf Height Module Card Guide\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e3500\/25\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e2.5 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eRack Options\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eFull-Size Rack\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eStandard 19-inch EIA, 14 Module Slots\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eMini-Rack\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCompact 12-inch, 7 Module Slots\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eMounting Formats\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePanel Mount:\u003c\/strong\u003e Rectangular cut-out panels, secured with clamps. Rear access to wiring and I\/O modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Mount:\u003c\/strong\u003e Standard 19-inch EIA rails. Rear access to connections and modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBulkhead Mount:\u003c\/strong\u003e Wall or panel mounting with front access. (Not available for Mini-Rack)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eHalf-height module card guide\u003c\/li\u003e\n  \u003cli\u003eSecures and aligns monitor modules\u003c\/li\u003e\n  \u003cli\u003eCompatible with full-size and mini-racks\u003c\/li\u003e\n  \u003cli\u003eSupports panel, rack, and bulkhead mounting\u003c\/li\u003e\n  \u003cli\u003eLightweight 2.5 kg design\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3500 Monitoring System racks\u003c\/li\u003e\n  \u003cli\u003eTurbine supervisory systems\u003c\/li\u003e\n  \u003cli\u003eCompressor monitoring installations\u003c\/li\u003e\n  \u003cli\u003ePower generation facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What racks are compatible with the 125565-01?\u003c\/strong\u003e\u003cbr\u003e\nA1: Full-size 19-inch EIA racks (14 slots) and mini-racks (7 slots).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the weight?\u003c\/strong\u003e\u003cbr\u003e\nA2: Approximately 2.5 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What mounting formats are available?\u003c\/strong\u003e\u003cbr\u003e\nA3: Panel mount, rack mount, and bulkhead mount (Mini-Rack not available for bulkhead).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050446585988,"sku":"125565-01","price":221.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/125565-01.jpg?v=1783862294"},{"product_id":"bently-nevada-3500-05-01-03-00-00-01-14-slot-rack-module","title":"Bently Nevada 3500\/05-01-03-00-00-01 14-Slot Rack Module","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eBently Nevada 3500\/05-01-03-00-00-01 14-Slot Rack Chassis\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/05-01-03-00-00-01\u003c\/b\u003e is a 14-slot rack chassis designed for the Bently Nevada 3500 monitoring system. It provides a rugged mounting platform for monitoring modules in critical turbomachinery applications such as compressors, turbines, and pumps. This rack ensures reliable operation in harsh industrial environments.\u003c\/p\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eOrdering Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/05-01-03-00-00-01\u003c\/b\u003e part number follows this structure: \u003cb style=\"color: #0056b3;\"\u003e3500\/05-AA-BB-CC-DD-EE\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eAA – Rack Size:\u003c\/b\u003e 01 = 19-inch (standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eBB – Mounting Options:\u003c\/b\u003e 03 = Bulkhead mount (not available in Mini-Rack)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eCC – Agency Approval:\u003c\/b\u003e 00 = None\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eDD – Reserved Options:\u003c\/b\u003e 00 = None\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eEE – European Compliance:\u003c\/b\u003e 01 = CE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/05-01-03-00-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRack Size\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e19-inch (standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNumber of Module Slots\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMounting Options\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBulkhead mount (not available in Mini-Rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eEuropean Compliance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions (L x W x H)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e48.26 x 34.92 x 26.59 cm (19.0 x 13.75 x 10.47 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e4.5 kg (9.9 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-20°C to +60°C (-4°F to +140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120\/240 VAC or 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eMount the rack in a clean, dry location with adequate ventilation. Allow 50mm clearance on all sides for airflow.\u003c\/li\u003e\n\u003cli\u003eUse the bulkhead mounting option for secure installation on panel or cabinet walls.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding using the rack's ground lug with 4 mm² (AWG 11) stranded wire.\u003c\/li\u003e\n\u003cli\u003ePower supply input should be protected with a 10A circuit breaker per local electrical codes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 3500\/05 Rack\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eAccommodates up to 14 monitoring modules for comprehensive machinery protection.\u003c\/li\u003e\n\u003cli\u003eCE compliance ensures adherence to European safety and EMC standards.\u003c\/li\u003e\n\u003cli\u003eBulkhead mounting provides stable installation in high-vibration environments.\u003c\/li\u003e\n\u003cli\u003eCompatible with all 3500 series modules including TDI, vibration, and temperature monitors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e What is the maximum power draw for a fully loaded 14-slot rack?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e A fully populated rack draws approximately 150W at 24VDC. Use a power supply rated for 200W minimum to allow headroom.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e Can I mount this rack in a standard 19-inch server cabinet?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Yes, the 19-inch rack size fits standard server cabinets. Use the included mounting brackets for secure rail installation.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e What is the recommended maintenance schedule for the rack?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Inspect all module connections annually. Clean dust filters (if installed) every 6 months. Check ground continuity annually.\u003c\/p\u003e\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #0056b3; text-decoration: none; font-weight: bold;\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050449928324,"sku":"3500\/05-01-03-00-00-01","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_05-01-03-00-00-01-1.jpg?v=1783853791"},{"product_id":"3500-05-01-03-01-00-01-bently-nevada-rack-14-module-slots","title":"3500\/05-01-03-01-00-01 Bently Nevada Rack 14 Module Slots","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/05-01-03-01-00-01 System Rack\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color:#2c6e9e;\"\u003eBently Nevada 3500\/05-01-03-01-00-01\u003c\/strong\u003e is a 19 inch system rack with 14 module slots. Features bulkhead mount option. CSA NRTL C Class 1 Division 2 certified. CE compliant. Rack weight 4.5 kg.\u003c\/p\u003e\n\n\u003ch3\u003eModel Number Breakdown\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eOption Code\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eDescription\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e01 (A: Rack Size)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e19 inch Rack (14 module slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e03 (B: Mounting)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eBulkhead Mount Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e01 (C: Agency Approval)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCSA NRTL C (Class 1 Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e00 (D: Reserved)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e01 (E: European Compliance)\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eValue\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e3500\/05-01-03-01-00-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eRack Size\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e19 inch (14 module slots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMounting Type\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eBulkhead Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCSA NRTL C Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eHazardous Location\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eClass I Zone 2 AEx\/Ex nA nC ic IIC T4 Gc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eEuropean Compliance\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eCE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e-20°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e4.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eAvailable Rack Configurations\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px;\"\u003e\n\u003ctbody\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left; width:40%;\"\u003eConfiguration\u003c\/th\u003e\n\u003cth style=\"padding:10px; border:1px solid #ccc; text-align:left;\"\u003eDescription\u003c\/th\u003e\n\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eFull Size Rack\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e19 inch EIA rack with 14 module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#fff;\"\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003eMini Rack\u003c\/td\u003e\n\u003ctd style=\"padding:10px; border:1px solid #ccc;\"\u003e12 inch rack with 7 module slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e19 inch rack with 14 module slots\u003c\/li\u003e\n\u003cli\u003eBulkhead mount option\u003c\/li\u003e\n\u003cli\u003eCSA NRTL C Class 1 Division 2 certified\u003c\/li\u003e\n\u003cli\u003eClass I Zone 2 AEx\/Ex nA nC ic IIC T4 Gc\u003c\/li\u003e\n\u003cli\u003eCE compliant for European market\u003c\/li\u003e\n\u003cli\u003eOperating temperature -20°C to +65°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Mounting Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eBulkhead Mounting:\u003c\/strong\u003e Secure rack using four mounting bolts through bulkhead flanges. Verify rack is level before tightening. Use appropriate hardware for wall or panel attachment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect rack ground stud to plant earth ground using #10 AWG wire. Proper grounding essential for hazardous area compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eModule Installation:\u003c\/strong\u003e Insert modules into slots from left to right. Each slot accepts full-height modules. Secure each module with mounting screws after seating.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many module slots does this rack provide?\u003c\/strong\u003e\u003cbr\u003eA1: 14 module slots in 19 inch EIA rack configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the rack weight?\u003c\/strong\u003e\u003cbr\u003eA2: 4.5 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What hazardous location certifications does this rack hold?\u003c\/strong\u003e\u003cbr\u003eA3: CSA Class 1 Division 2 Groups A B C D and Class I Zone 2 AEx\/Ex nA nC ic IIC T4 Gc.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050449961092,"sku":"3500\/05-01-03-01-00-01","price":347.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_05-01-03-01-00-01.jpg?v=1783861469"},{"product_id":"bently-nevada-3500-15-universal-ac-power-supply-2-8a","title":"Bently Nevada 3500\/15 Universal AC Power Supply 2.8A","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 Power Supply Module\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15\u003c\/strong\u003e is a half-height power supply module for 3500 rack systems. Fits designated slots on left side of rack. Supports universal AC, high voltage DC and low voltage DC inputs. Redundant configurations with one or two power supplies. Module weight 1.39 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/15 Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eUniversal AC Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e2.8 A rms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHigh Voltage DC Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e2.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eLow Voltage DC Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e11.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePower Supply Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePIM Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 x 25.4 x 114.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePower Supply Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePIM Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHalf-height module for 3500 rack left side slots\u003c\/li\u003e\n\u003cli\u003eSupports universal AC, high voltage DC and low voltage DC inputs\u003c\/li\u003e\n\u003cli\u003eOne or two power supplies per rack\u003c\/li\u003e\n\u003cli\u003ePowers full rack with any combination of AC and DC supplies\u003c\/li\u003e\n\u003cli\u003eNo minimum rack load required\u003c\/li\u003e\n\u003cli\u003eRedundant configuration capable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What current ratings are available for different input types?\u003c\/strong\u003e\u003cbr\u003eA1: Universal AC 2.8 A rms maximum, High Voltage DC 2.5 A maximum, Low Voltage DC 11.0 A maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the power supply dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eA2: Dimensions 120.7 x 50.8 x 251.5 mm. Weight 1.39 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the operating temperature range?\u003c\/strong\u003e\u003cbr\u003eA4: -30°C to +65°C (-22°F to +150°F).\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450026628,"sku":"3500\/15","price":224.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500-15-0.jpg?v=1783254469"},{"product_id":"3500-15-01-01-00-bently-nevada-3500-supply-module","title":"3500\/15-01-01-00 Bently Nevada 3500 Supply Module","description":"\u003ch2 style=\"color: #333333;\"\u003eBently Nevada 3500\/15-01-01-00 Power Supply Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eBently Nevada 3500\/15-01-01-00\u003c\/strong\u003e is a power supply module for the 3500 monitoring system. Features low voltage AC input (85 to 132V AC) in the top slot with no supply in the bottom slot for single-supply configurations. Weight: 1.39 kg (3.1 lbs).\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3500\/15-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eTop Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eLow Voltage AC (85-132V AC rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBottom Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNo supply (single-supply configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNone (Option 00)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e120.7 × 50.8 × 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e1.39 kg (3.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCurrent Draw (Universal AC)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e2.8A RMS (maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eConfiguration Breakdown\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eLow Voltage AC (85-132V AC) - Top Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNo supply in bottom slot (single-supply configuration)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e00\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eNo agency approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eProvides regulated power to 3500 monitoring system rack\u003c\/li\u003e\n\u003cli\u003eLow voltage AC input range 85-132V AC\u003c\/li\u003e\n\u003cli\u003eSingle-supply configuration (top slot only)\u003c\/li\u003e\n\u003cli\u003eCompact form factor for standard 3500 rack installation\u003c\/li\u003e\n\u003cli\u003eReliable power delivery for monitoring system components\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Top slot must contain the power supply module. Bottom slot remains empty for single-supply configuration. Do not install modules in the bottom slot when using single-supply setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Use 14 AWG minimum for AC input wiring. Torque terminals to 0.8 N·m (7 in·lb). Connect earth ground directly to the chassis ground lug before energizing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoltage Verification:\u003c\/strong\u003e Measure incoming AC at the terminal block before inserting the module. Verify 85-132V AC between L1 and L2. Do not apply DC voltage to AC-rated terminals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Budget:\u003c\/strong\u003e Full rack current draw for universal AC is 2.8A RMS maximum. Calculate total rack load before adding expansion modules to avoid overloading the supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e For redundant configurations, use option 02 in the bottom slot with a second power supply. This module uses single-supply only.\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. Can I add a second power supply later for redundancy?\u003c\/strong\u003e\u003cbr\u003eA1. No. This configuration (bottom slot option 01) is fixed for single-supply use. You cannot retrofit a second supply into the bottom slot without replacing the unit with a dual-supply option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What wire gauge should I use for AC input?\u003c\/strong\u003e\u003cbr\u003eA2. Use 14 AWG minimum for AC input wiring to handle the 2.8A current draw. Terminals accept up to 12 AWG. Torque to 0.8 N·m.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. How do I verify the module is supplying correct voltage?\u003c\/strong\u003e\u003cbr\u003eA3. Check the front panel LED. Green indicates normal operation. Measure +24V DC on the backplane test points with a multimeter. If LED is off, check AC input voltage and fuse condition.\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eDownload\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca style=\"color: rgb(51, 51, 51); text-decoration: underline; font-weight: bold;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450092164,"sku":"3500\/15-01-01-00","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500-15-01-01-00.jpg?v=1783347387"},{"product_id":"3500-15-03-03-01-bently-nevada-dual-dc-supply-1-39kg","title":"3500\/15-03-03-01 Bently Nevada Dual DC Supply 1.39kg","description":"\u003ch2 style=\"color: #333333;\"\u003eBently Nevada 3500\/15-03-03-01 Power Supply Module\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eBently Nevada 3500\/15-03-03-01\u003c\/strong\u003e is a power supply module for the 3500 monitoring system. Features High Voltage DC (88-140V DC) in top slot and High Voltage DC (88-140V DC) in bottom slot. CSA \/ NRTL \/ C Class 1 Division 2 approved. Weight: 1.39 kg (3.1 lbs).\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e3500\/15-03-03-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003ePower Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eTop Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBottom Slot Supply\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eCSA \/ NRTL \/ C (Class 1 Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e120.7 × 50.8 × 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e1.39 kg (3.1 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eConfiguration Breakdown\u003c\/h3\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eCode\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eDescription\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e03\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC) - Top Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e03\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eHigh Voltage DC (88-140V DC) - Bottom Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eCSA \/ NRTL \/ C (Class 1 Division 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\n\u003cul\u003e\n\u003cli\u003eDual high-voltage DC power supplies for redundant operation\u003c\/li\u003e\n\u003cli\u003eCSA \/ NRTL \/ C Class 1 Division 2 certified for hazardous areas\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003eProvides regulated power to 3500 monitoring system rack\u003c\/li\u003e\n\u003cli\u003eCompact form factor for standard 3500 rack installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eSlot Placement:\u003c\/strong\u003e Top and bottom slots both require High Voltage DC supplies. Ensure both modules are properly seated and locked.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e Use 14 AWG minimum for DC input wiring. Connect positive to L1 and negative to L2. Torque terminals to 0.8 N·m (7 in·lb). Connect earth ground to chassis ground lug before energizing.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVoltage Verification:\u003c\/strong\u003e Measure incoming DC at the terminal block before inserting modules. Verify 88-140V DC between L1 and L2. Polarity must be correct.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Dual supplies provide hot-standby redundancy. If one supply fails, the second continues powering the rack without interruption.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eFuse Check:\u003c\/strong\u003e Each supply has internal fuses. Before replacing a module, check AC\/DC input and fuse condition on the front panel.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1. Can I mix AC and DC supplies in this configuration?\u003c\/strong\u003e\u003cbr\u003e\nA1. No. This configuration uses High Voltage DC in both slots. Mixing AC and DC supplies requires a different part number with appropriate slot codes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2. What is the maximum rack load for dual DC supplies?\u003c\/strong\u003e\u003cbr\u003e\nA2. Each DC supply provides 2.5A maximum. Dual supplies share the load. Total rack current should not exceed 5A.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3. How do I test redundancy operation?\u003c\/strong\u003e\u003cbr\u003e\nA3. Remove one supply while the rack is running. The second supply should maintain power with no interruption. Green LED on the remaining supply stays lit. Replace the removed supply within 30 seconds.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333333;\"\u003eDownload\u003c\/h3\u003e\n\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" style=\"color: #333333; text-decoration: none; font-weight: bold;\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450714756,"sku":"3500\/15-03-03-01","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-03-03-01-2.jpg?v=1783749299"},{"product_id":"3500-15-133300-01-power-supply-module-bently-nevada","title":"3500\/15 133300-01  Power Supply Module Bently Nevada","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/15 133300-01 Low Voltage DC Power Input Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 133300-01\u003c\/strong\u003e is a Low Voltage DC Power Input Module for the 3500 Series rack. Provides power conversion with 20-30 Vdc input and 11.0A maximum current draw. Redundant power supply capable.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eProduct No.\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e133300-01 (3500\/15)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eLow Voltage DC Power Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e20-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e11.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eDimensions\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHeight x Width x Depth\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e120.7 x 25.4 x 114.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInches\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e4.75 x 1.0 x 4.5 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eProtection Features\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eUnder-voltage protection does not harm supply or PIM\u003c\/li\u003e\n\u003cli\u003eOver-voltage causes fuse to open on PIM\u003c\/li\u003e\n\u003cli\u003eSupply OK LED indicates proper operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eRack Installation\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003ePower supply module: Two half-height slots on left side of rack\u003c\/li\u003e\n\u003cli\u003eRedundant power supplies supported (both slots can hold a supply)\u003c\/li\u003e\n\u003cli\u003ePower input module: Special half-height module directly behind associated power supply\u003c\/li\u003e\n\u003cli\u003eNo minimum rack load required\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eCertifications\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eFCC Part 15 Compliant\u003c\/li\u003e\n\u003cli\u003eEMC Directive 2014\/30\/EU (EN 61000-6-2, EN 61000-6-4)\u003c\/li\u003e\n\u003cli\u003eLV Directive 2014\/35\/EU (EN 61010-1)\u003c\/li\u003e\n\u003cli\u003eRoHS Directive 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eDNV GL Maritime\u003c\/li\u003e\n\u003cli\u003eABS Steel Vessels Rules and Offshore Units\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eHazardous Area Approvals\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003ecNRTLus: Class I, Zone 2 \/ Division 2, Groups A, B, C, D; T4 @ -20°C to +65°C\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx: II 3 G Ex nA nC ic IIC T4 Gc \/ Ex ec nC ic IIC T4 Gc; T4 @ -20°C to +65°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the input voltage range?\u003c\/strong\u003e\u003cbr\u003eA1: 20-30 Vdc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can two power supplies be installed for redundancy?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, both half-height slots can hold a power supply simultaneously.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum current draw?\u003c\/strong\u003e\u003cbr\u003eA3: 11.0 A for a full rack configuration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450747524,"sku":"133300-01","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/133300-01_3.jpg?v=1783254827"},{"product_id":"power-supply-module-bently-nevada-3500-15-05-00-02","title":"Power Supply Module Bently Nevada 3500\/15-05-00-02","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/15-05-00-02 Universal AC Power Supply Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 3500\/15-05-00-02\u003c\/strong\u003e is a universal AC power supply module for 3500 Series machinery monitoring systems. Features dual redundant slots with 85-264 Vac input and ATEX\/IECEx\/CSA hazardous area approvals.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eOrdering Configuration\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-05 (Slot A)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eUniversal AC Voltage (85-264 Vac rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-05 (Slot B)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eUniversal AC Voltage (85-264 Vac rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-02 (Approval)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eATEX \/ IECEx \/ CSA (Class 1, Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eElectrical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eFrequency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e2.8 A rms maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eComponent\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eH x W x D\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eWeight\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003ePower Supply Module\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003ePower Input Module\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e120.7 x 25.4 x 114.3 mm\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0.34 kg (0.75 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eHazardous Area Approvals\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003cli\u003eCSA (Class 1, Zone 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What approvals does the -02 option provide?\u003c\/strong\u003e\u003cbr\u003eA1: ATEX, IECEx, and CSA Class 1 Zone 2 certification.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum current draw for a full rack?\u003c\/strong\u003e\u003cbr\u003eA2: 2.8 A rms maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the frequency range?\u003c\/strong\u003e\u003cbr\u003eA3: 47 to 63 Hz.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450780292,"sku":"3500\/15-05-00-02","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-00-02.jpg?v=1783758922"},{"product_id":"3500-15-05-05-00-bently-nevada-power-supply-65w-85-264v","title":"3500\/15-05-05-00 Bently Nevada Power Supply 65W 85-264V","description":"\u003ch2\u003e3500-15-05-05-00 Bently Nevada Power Supply – 65W 85-264VAC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eBently Nevada 3500-15-05-05-00\u003c\/strong\u003e is a universal AC power supply module for the 3500 Monitoring System. Accepts 85 to 264 VAC input and delivers 65 Watts output power.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e3500-15-05-05-00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePower Supply (106M1079-01 + 106M1081-01)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eU.S.A.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eNew and Original\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e12 Months\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCertificate\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCertificate of Origin (COO) Available\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e85-264 VAC RMS (Universal)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e47-63 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e65 Watts\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u0026gt;85%\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e25.15 x 5.08 x 12.07 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e1.39 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eSafety Standards\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eUL \/ CSA \/ TUV Certified\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatible Systems\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBently Nevada 3500 Monitoring System\u003c\/li\u003e\n  \u003cli\u003e3500-15 Rack Interfaces\u003c\/li\u003e\n  \u003cli\u003e3500-22M Transient Data Interface\u003c\/li\u003e\n  \u003cli\u003e3500-25 Keyphasor Module\u003c\/li\u003e\n  \u003cli\u003e3500-32 4-Channel Relay\u003c\/li\u003e\n  \u003cli\u003e3500-40M Analog Monitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eIndustry\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePower Generation\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eTurbine Control System Power\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eOil and Gas\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCompressor Monitoring Systems\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eMarine\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePropulsion Monitoring Backup Power\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eManufacturing\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCritical Machine Protection Systems\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3500-15 Power Supply Module\u003c\/li\u003e\n  \u003cli\u003eMounting Hardware\u003c\/li\u003e\n  \u003cli\u003eInstallation Guide\u003c\/li\u003e\n  \u003cli\u003eQuality Assurance Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUniversal AC input 85-264 VAC\u003c\/li\u003e\n  \u003cli\u003e65 Watts output power with \u0026gt;85% efficiency\u003c\/li\u003e\n  \u003cli\u003eUL, CSA, and TUV safety certified\u003c\/li\u003e\n  \u003cli\u003eDesigned for Bently Nevada 3500 Monitoring System\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range\u003c\/li\u003e\n  \u003cli\u003eCertificate of Origin available\u003c\/li\u003e\n  \u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the correct mounting orientation?\u003c\/strong\u003e\u003cbr\u003e\nA1: Install in the leftmost rack slot. Fully seat and secure with two retaining screws at 0.56 N·m (5 in·lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How to wire AC input?\u003c\/strong\u003e\u003cbr\u003e\nA2: Use 14-16 AWG 90°C wire. Connect L to terminal 1, N to terminal 2, Ground to terminal 3. Torque to 0.56 N·m. Use 6A circuit breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Green LED off, amber on. What to check?\u003c\/strong\u003e\u003cbr\u003e\nA3: Check AC voltage at terminals. If present but green off, internal fuse is blown. Amber indicates over-temp or over-current. Verify rack ventilation and ambient below 60°C.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Documentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\" style=\"color:#0066cc; font-weight:bold;\"\u003eDownload Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450813060,"sku":"3500\/15-05-00-05","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-00-05.jpg?v=1783342954"},{"product_id":"bently-nevada-3500-15-129478-01-hv-dc-pim-88-140v-2-5a","title":"Bently Nevada 3500\/15 129478-01 HV DC PIM 88-140V 2.5A","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 129478-01 High Voltage DC Power Input Module\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 129478-01\u003c\/strong\u003e is a high voltage DC power input module (PIM) for 3500 rack systems. Input voltage 88 to 140 V DC. Full rack current draw 2.5 A maximum. Used with High Voltage DC Power Supply. Module weight 0.34 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/15 129478-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHigh Voltage DC Power Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e88 to 140 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e2.5 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMinimum Loading\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNo minimum rack load required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 x 25.4 x 114.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.34 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh voltage DC input 88 to 140 V DC\u003c\/li\u003e\n\u003cli\u003e2.5 A maximum full rack current draw\u003c\/li\u003e\n\u003cli\u003eHalf-height module directly behind power supply\u003c\/li\u003e\n\u003cli\u003eNo minimum rack load required\u003c\/li\u003e\n\u003cli\u003eUnder-voltage does not harm supply or PIM\u003c\/li\u003e\n\u003cli\u003eOver-voltage causes fuse to open on PIM\u003c\/li\u003e\n\u003cli\u003eSupply OK front panel LED indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRack Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo half-height slots on left side of rack\u003c\/li\u003e\n\u003cli\u003eEach slot accommodates one power supply\u003c\/li\u003e\n\u003cli\u003eBoth slots can hold power supplies simultaneously for redundancy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eWiring Checklist:\u003c\/strong\u003e Verify DC source voltage between 88-140V before connection. Use appropriately rated DC circuit breaker. Connect positive to + terminal, negative to - terminal. Torque terminal screws to 0.56 Nm. Install PIM directly behind associated power supply slot. Under-voltage does not damage module. Over-voltage opens internal PIM fuse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect rack ground terminal to plant earth ground using #10 AWG wire. Keep DC power cables away from signal wiring. Rack must have proper earth ground before power application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Install two PIMs with two power supplies for redundant DC feed. Each PIM occupies one slot. Both can operate simultaneously. During replacement, remove failed unit after isolating DC source. Spare PIM slides directly in without rack power removal.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What voltage range does 129478-01 accept?\u003c\/strong\u003e\u003cbr\u003eA1: 88 to 140 V DC. Verify voltage at source terminals before connecting module. Over-voltage opens internal PIM fuse.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What torque for terminal connections?\u003c\/strong\u003e\u003cbr\u003eA2: Torque terminal screws to 0.56 Nm. Loose connections cause voltage drop and heating. Use ring terminals for stranded wire.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can I hot-swap the PIM?\u003c\/strong\u003e\u003cbr\u003eA3: No. Isolate DC source before removal. Rack does not need power down. Replace failed PIM by sliding new unit into same slot.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451107972,"sku":"129478-01","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/129478-01.jpg?v=1783344679"},{"product_id":"bently-nevada-3500-15-05-05-r0-power-supply-module","title":"Bently Nevada 3500\/15-05-05-R0 Power Supply Module","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15-05-05-R0 Power Supply Module\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15-05-05-R0\u003c\/strong\u003e is a dual universal AC power supply module for 3500 rack systems. Both top and bottom slots equipped with universal AC voltage (85 to 264 V AC rms). Delivers stable power for critical monitoring applications. Module weight 1.39 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/15-05-05-R0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTop Slot Supply Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e05: Universal AC Voltage (85 to 264 V AC rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBottom Slot Supply Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e05: Universal AC Voltage (85 to 264 V AC rms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 mm (4.75 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWidth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e50.8 mm (2.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDepth\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e251.5 mm (9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDual universal AC power supplies in top and bottom slots\u003c\/li\u003e\n\u003cli\u003eWide input voltage range 85 to 264 V AC rms\u003c\/li\u003e\n\u003cli\u003eRedundant configuration for uninterrupted operation\u003c\/li\u003e\n\u003cli\u003eCompact half-height design for 3500 rack\u003c\/li\u003e\n\u003cli\u003eStable power delivery for monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInstallation \u0026amp; Wiring Guide\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Install both power supplies into the two half-height slots on left side of 3500 rack. Secure with mounting screws. No special tools required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAC Wiring:\u003c\/strong\u003e Connect AC lines to terminal block: L for live, N for neutral, ground for earth. Use 14-16 AWG copper wire. Torque terminals to 0.5 Nm. Verify voltage between 85-264 VAC before energizing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRedundancy Check:\u003c\/strong\u003e Both supplies operate in parallel. One unit can power full rack if other fails. LED indicator shows supply OK status. Test each supply individually during commissioning.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What AC voltage range does 3500\/15-05-05-R0 accept?\u003c\/strong\u003e\u003cbr\u003eA1: 85 to 264 V AC rms universal input. Both top and bottom slots use same supply type.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What wire size for AC connections?\u003c\/strong\u003e\u003cbr\u003eA2: 14-16 AWG copper wire. Torque terminal screws to 0.5 Nm. Loose connections cause heating and intermittent faults.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can one supply power the entire rack if other fails?\u003c\/strong\u003e\u003cbr\u003eA3: Yes. Both supplies operate in redundant parallel configuration. Each unit rated for full rack load.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451140740,"sku":"3500\/15-05-05-R0","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-05-R0.jpg?v=1783746181"},{"product_id":"3500-15-07-07-02-bently-nevada-power-supply-20-30-vdc-11a","title":"3500\/15-07-07-02 Bently Nevada Power Supply 20 30 VDC 11A","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-15-07-07-02\u003c\/span\u003e 3500 Series Power Supply Module\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-15-07-07-02\u003c\/span\u003e is a 3500 series rack power supply module. It accepts 20 to 30 VDC input and delivers 11.0A maximum full rack current. Features under voltage and over voltage protection. Designed for 3500 monitoring system racks with PIM interface.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3500-15-07-07-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3500 Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e20 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e11.0 A max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eUnder Voltage Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eNo adverse effect\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOver Voltage Protection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eFuse on PIM opens\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDimensions H x W x D\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e120.7 x 50.8 x 251.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1.39 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eInstall in 3500 rack leftmost slot. Connect PIM cable before powering on. Verify input voltage 20 to 30 VDC at terminals. Tighten terminal screws to 1.1 Nm. Allow 50mm clearance for airflow.\u003c\/p\u003e\n\n\u003ch3\u003eWiring\u003c\/h3\u003e\n\u003cp\u003eUse 14 AWG copper wire for DC input. Connect positive to terminal 1 and negative to terminal 2. Earth ground to chassis lug. Use shielded twisted pair for signal wiring. Keep DC input cables separate from AC mains.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What happens during over voltage condition?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e The fuse on PIM opens protecting the system. Replace PIM fuse with same rating. Identify and correct input voltage source fault before reinstallation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Can I hot swap this module?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e No. Power down rack before removal or installation. Insert or remove only with system power off to prevent damage to PIM and backplane.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e How to check under voltage performance?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Measure input at power supply terminals under full load. Voltage below 20VDC triggers no adverse effect but monitor system stability. Verify DC source capacity for full rack load 11A.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451206276,"sku":"3500\/15-07-07-02","price":216.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-07-07-02.jpg?v=1783345707"},{"product_id":"transient-data-interface-bently-nevada-3500-22-01-01-r0","title":"Transient Data Interface Bently Nevada 3500\/22-01-01-R0","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/22-01-01-R0 Transient Data Interface\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 3500\/22-01-01-R0\u003c\/strong\u003e is a Transient Data Interface consisting of the 288055-01 Standard TDI Module and 146031-01 I\/O Module. Designed for standard monitoring applications with 10Base-T\/100Base-TX Ethernet.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eOrdering Configuration\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eOption\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eTransient Data Interface Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStandard (for standard monitoring applications)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eI\/O Module Type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e10Base-T\/100Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eAgency Approval Option\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eR0\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStandard approval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eComponent Details\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003ePart Number\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e288055-01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStandard Transient Data Interface Module with USB Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e146031-01\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eTransient Data Interface I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eBattery Life (Powered)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e38 years @ 50°C (122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eBattery Life (Unpowered)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e12 years @ 50°C (122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight (Total)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1.11 kg (TDI: 0.91 kg + I\/O: 0.20 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eDimensions\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eDepth x Width x Height\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e241.8 x 24.4 x 241.3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eLong operational battery life for extended industrial use\u003c\/li\u003e\n\u003cli\u003e10Base-T\/100Base-TX Ethernet for efficient data transmission\u003c\/li\u003e\n\u003cli\u003eCompact design with stable weight distribution\u003c\/li\u003e\n\u003cli\u003eReliable operation in temperature extremes from -30°C to +65°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I install the 3500\/22 TDI in the rack?\u003c\/strong\u003e\u003cbr\u003eA1: Insert the TDI module (288055-01) into any front slot and the I\/O module (146031-01) into the corresponding rear slot. Secure both with captive screws. Connect the USB cable between modules and Ethernet to your network.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the expected battery life?\u003c\/strong\u003e\u003cbr\u003eA2: 38 years when powered at 50°C, 12 years when unpowered at same temperature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What network speeds are supported?\u003c\/strong\u003e\u003cbr\u003eA3: 10Base-T and 100Base-TX Ethernet.\u003c\/p\u003e\n\n\u003cp style=\"margin-top:20px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" target=\"_blank\" style=\"display:inline-block; background-color:#0066b3; color:white; padding:10px 20px; text-decoration:none; border-radius:4px;\"\u003eDownload Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451271812,"sku":"3500\/22-01-01-R0","price":396.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22-01-01-R0.jpg?v=1783849383"},{"product_id":"bently-nevada-3500-22-01-03-01-tdi-module-ethernet-i-o","title":"Bently Nevada 3500\/22-01-03-01 TDI Module Ethernet I\/O","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eBently Nevada 3500\/22-01-03-01 Transient Data Interface Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22-01-03-01 TDI Module\u003c\/b\u003e delivers high-speed transient data capture for critical turbomachinery. It captures waveform snapshots and event-triggered records, enabling advanced diagnostics for gas turbines, compressors, and steam turbines. This module serves as the communication gateway between the 3500 rack and plant management systems, ensuring continuous monitoring and predictive maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eOrdering Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22-01-03-01\u003c\/b\u003e part number follows this structure: \u003cb style=\"color: #0056b3;\"\u003e3500\/22-AA-BB-CC\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eAA – Transient Data Interface Type:\u003c\/b\u003e 01 = Standard (for standard monitoring applications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eBB – I\/O Module Type:\u003c\/b\u003e 03 = 10Base-T\/100Base-TX Ethernet with gold-plated OK Relay contacts\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eCC – Agency Approval:\u003c\/b\u003e 01 = CSA\/NRTL\/C (Class 1, Division 2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModule Dimensions (TDI)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTDI Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Powered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e38 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Unpowered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eInstall the TDI module in a full-height front slot; the matching I\/O module occupies one full-height rear slot.\u003c\/li\u003e\n\u003cli\u003eUse twisted-pair shielded cables for Ethernet connections; maintain a minimum bend radius of 10x cable diameter.\u003c\/li\u003e\n\u003cli\u003eFor fiber optic variants (100Base-FX), clean connectors with lint-free wipes and inspect for \u0026lt; 0.5 dB loss.\u003c\/li\u003e\n\u003cli\u003eWhen replacing a legacy 3500\/22, ensure the firmware revision is updated to support the new I\/O options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 3500\/22-01-03-01\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eProvides buffered transient data for post-event analysis and predictive trending.\u003c\/li\u003e\n\u003cli\u003eSeamless integration with System 1® software and DCS\/PLC via Modbus or OPC.\u003c\/li\u003e\n\u003cli\u003eExtended temperature range and conformal coating options for harsh environments.\u003c\/li\u003e\n\u003cli\u003eBackward compatible with existing 3500 racks while offering faster Ethernet throughput.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e How to verify correct Ethernet communication after installation?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e Ping the assigned IP from the engineering workstation. Check link LED status on both the I\/O module and switch. If using fiber, verify light levels with a power meter – should read between -20 and -14 dBm for multimode.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e What is the proper grounding procedure for the I\/O module?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Connect the rear slot ground lug directly to the rack's earth ground bus. Use 4 mm² (AWG 11) stranded wire. Ensure the Ethernet cable shield is grounded only at the switch end to avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e Battery replacement steps without losing configuration?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Keep the 3500 rack powered during battery swap. Locate the 3V lithium coin cell on the TDI board. Remove old cell and insert new within 2 minutes – the supercapacitor holds memory for up to 30 minutes. Re-initialize time\/date after replacement.\u003c\/p\u003e\n\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca style=\"color: #0056b3; text-decoration: none; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" style=\"display: inline-block; background-color: #0056b3; color: #ffffff; padding: 10px 20px; text-decoration: none; border-radius: 4px; font-weight: bold;\" target=\"_blank\"\u003eDownload Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451435652,"sku":"3500\/22-01-03-01","price":229.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22-01-03-01.jpg?v=1783849091"},{"product_id":"3500-22m-01-01-00-bently-nevada-tdi-module-3500-22m","title":"3500\/22M-01-01-00 Bently Nevada TDI Module 3500\/22M","description":"\u003ch2\u003eBently Nevada 3500\/22M-01-01-00 TDI Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eBently Nevada 3500\/22M-01-01-00\u003c\/strong\u003e 3500\/22M Transient Data Interface (TDI) Module with 10Base-T\/100Base-TX Ethernet I\/O. Provides high-speed data communication between 3500 Machinery Protection System and host software. Supports BN Host Protocol and BN TDI Protocol for configuration, data acquisition, and System 1 integration. Total weight: 1.11 kg.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e10Base-T\/100Base-TX Ethernet I\/O (autosensing). BN Host Protocol and BN TDI Protocol support. Front panel USB-B port (115.2 kbaud). OK relay with arc suppressors (5A @ 24Vdc\/120Vac). Trip Multiply, Alarm Inhibit, and Rack Reset system contacts. 10.5W power consumption. Operating temperature -30°C to +65°C. 38 years battery life @ 50°C (powered).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e3500\/22M-01-01-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003e3500\/22M TDI Module and I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDI Type (Option A)\u003c\/td\u003e\n\u003ctd\u003e01 = Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Type (Option B)\u003c\/td\u003e\n\u003ctd\u003e01 = 10Base-T\/100Base-TX Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval (Option C)\u003c\/td\u003e\n\u003ctd\u003e00 = None\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFront Panel Communication\u003c\/td\u003e\n\u003ctd\u003eUSB-B (115.2 kbaud max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet I\/O\u003c\/td\u003e\n\u003ctd\u003e10Base-T\/100Base-TX, RJ-45, 100m max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtocols Supported\u003c\/td\u003e\n\u003ctd\u003eBN Host Protocol, BN TDI Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOK Relay Rating\u003c\/td\u003e\n\u003ctd\u003e5A @ 24Vdc\/120Vac, 120W\/600VA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArc Protection\u003c\/td\u003e\n\u003ctd\u003eArc suppressors provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDI Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDI Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd\u003e241.3 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Weight\u003c\/td\u003e\n\u003ctd\u003e1.11 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (TDI)\u003c\/td\u003e\n\u003ctd\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Space (I\/O)\u003c\/td\u003e\n\u003ctd\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (Powered)\u003c\/td\u003e\n\u003ctd\u003e38 years @ 50°C (122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life (Unpowered)\u003c\/td\u003e\n\u003ctd\u003e12 years @ 50°C (122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eMade in U.S.A.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Code Breakdown\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e3500\/22M-01-01-00\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:01\u003c\/strong\u003e – Standard TDI for standard monitoring applications.\u003cbr\u003e\u003cstrong\u003eB:01\u003c\/strong\u003e – 10Base-T\/100Base-TX Ethernet I\/O module.\u003cbr\u003e\u003cstrong\u003eC:00\u003c\/strong\u003e – No agency approval.\u003c\/p\u003e\n\u003ch3\u003eSystem Contacts\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Multiply\u003c\/td\u003e\n\u003ctd\u003eDry contact to Common, \u0026lt;1mA, places rack in Trip Multiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Inhibit\u003c\/td\u003e\n\u003ctd\u003eDry contact to Common, \u0026lt;1mA, inhibits all alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRack Reset\u003c\/td\u003e\n\u003ctd\u003eDry contact to Common, \u0026lt;1mA, clears latched alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eInstall TDI module in full-height front slot (Slot 1, next to power supplies). Install I\/O module in corresponding full-height rear slot. Connect Ethernet via RJ-45 (100m max). Use USB-B cable (5m max) for local configuration. Configure OK relay contact (OPEN\/CLOSED) for NOT OK annunciation. When upgrading from RIM, remove RIM and RIM I\/O before installing TDI I\/O and TDI.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eProvides high-speed data extraction for condition monitoring and diagnostics. Dual protocol support (BN Host and BN TDI) ensures compatibility with 3500 Configuration Software and System 1. Ethernet connectivity enables remote monitoring and configuration. System contacts (Trip Multiply, Alarm Inhibit, Rack Reset) provide external control. Long battery life preserves configuration during power loss.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What protocols does the 3500\/22M support?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e BN Host Protocol (Configuration, Data Acquisition, Display Software) and BN TDI Protocol (System 1 Condition Monitoring).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the maximum Ethernet cable length?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 100 metres (328 feet) for 10Base-T\/100Base-TX.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the function of the OK relay?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Indicates normal rack operation or fault detection. User-selectable OPEN or CLOSED contact for NOT OK condition. Normally Energized operation.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451501188,"sku":"3500\/22M-01-01-00","price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500-22-2_09f94ba6-e4be-4371-82d1-eeef1d703c96.jpg?v=1787495451"},{"product_id":"3500-22m-01-01-01-tdi-module-ethernet-bently-nevada","title":"3500\/22M-01-01-01 TDI Module Ethernet - Bently Nevada","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-22M-01-01-01\u003c\/span\u003e Transient Data Interface Module\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eBently Nevada \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e3500-22M-01-01-01\u003c\/span\u003e is a Transient Data Interface module for 3500 monitoring systems. It combines rack interface functions with data collection capability. Provides Ethernet connectivity via 10Base-T or 100Base-TX. Collects steady state and transient dynamic data from M series monitors. Resides in Slot 1 adjacent to power supplies.\u003c\/p\u003e\n\n\u003ch3\u003eModel Number Decoder\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePosition\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCode\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMeaning\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eA\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eStandard TDI for monitoring applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eB\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10Base-T\/100Base-TX Ethernet I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e01\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCSA\/NRTL\/C Class 1 Division 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3500-22M-01-01-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eTransient Data Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10.5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eEthernet I\/O\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10Base-T \/ 100Base-TX autosensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eUSB Port\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eUSB-B (5m cable max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOK Relay Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e5A @ 24V DC \/ 120V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModule Dimensions H x W x D\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 241.8 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModule Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e95% non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBattery Life Powered\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e38 years @ 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBattery Life Unpowered\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e12 years @ 50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eInstall TDI module in Slot 1 of 3500 rack. Insert I\/O module in rear slot directly behind TDI. Set rack address using front panel switch. Connect Ethernet cable to RJ-45 port. USB port for local configuration. Use shielded Category 5 cable for Ethernet. Maximum cable length 100 meters.\u003c\/p\u003e\n\n\u003ch3\u003eWiring\u003c\/h3\u003e\n\u003cp\u003eSystem contacts are dry contact to common. Trip Multiply input uses \u0026lt;1mA. Alarm Inhibit input uses \u0026lt;1mA. Rack Reset input uses \u0026lt;1mA. OK Relay is normally energized. Connect Signal Common to single point instrument ground using 2-pin connector. Slide PIM switch to \"HP\" position when grounding Signal Common.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the upgrade sequence from RIM to TDI?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Remove RIM first. Remove RIM I\/O. Insert TDI I\/O. Insert TDI. Leaving RIM I\/O installed will damage new TDI.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the maximum Ethernet cable length?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e 100 meters (328 feet) for 10Base-T\/100Base-TX using Category 5 shielded cable. USB cable max is 5 meters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What data collection modes are supported?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Static data capture is standard. Dynamic and transient data require Channel Enabling Disk. Supports 48 channels of waveform collection with user configurable sampling rates.\u003c\/p\u003e\n\n\u003ch3\u003eDownload\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" target=\"_blank\" style=\"color: #2980b9; font-weight: bold;\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050451533956,"sku":"3500\/22M-01-01-01","price":367.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22M-01-01-01.jpg?v=1783849942"},{"product_id":"bently-nevada-3500-33-01-00-16-channel-relay-module","title":"Bently Nevada 3500\/33-01-00 16-Channel Relay Module","description":"\u003ch2\u003eBently Nevada 3500\/33-01-00 16-Channel Relay Module\u003c\/h2\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5276;\"\u003eBently Nevada 3500\/33-01-00\u003c\/strong\u003e is a 16-Channel Relay Module for 3500 rack systems. Each channel features a single-pole double-throw (SPDT) relay with epoxy sealing and built-in arc suppression for reliable alarm output in machinery protection applications.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Identification\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Number:\u003c\/strong\u003e 3500\/33-01-00\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e 16-Channel Relay Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOrigin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eModel Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e01\u003c\/strong\u003e – 16-Channel Relay Output Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00\u003c\/strong\u003e – No Agency Approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 60%;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMain Module (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 × 24.4 × 242 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eI\/O Module (H×W×D)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e241 × 24.4 × 99.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5.8 W typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eSPDT (Single-Pole Double-Throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Sealing\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eEpoxy-sealed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eArc Suppressor\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e250 Vrms standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eContact Life\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e10,000 cycles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Groups\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e4 groups of 4 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eRelay Operation\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eSwitch selectable ND or NE per group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMain Module Rack Space\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 full-height front slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eI\/O Module Rack Space\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 full-height rear slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eContact Ratings\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 30%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 35%;\"\u003eStandard Relays\u003c\/th\u003e\n\u003cth style=\"padding: 8px 12px; border: 1px solid #ccc; text-align: left; width: 35%;\"\u003eLow Current Relays\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMin Switched Current\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e100 mA @ 5 Vdc\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1 mA @ 1 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e100 mA @ 48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e125 Vdc\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e48 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Current (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e5 A\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Voltage (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e250 Vac\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e120 Vac\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Power (DC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e70 W @ 24 Vdc\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eMax Switched Power (AC)\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003e1200 VA\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 12px; border: 1px solid #ccc;\"\u003eN\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eFront Panel LEDs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOK LED:\u003c\/strong\u003e Illuminated when module is operating properly\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTX\/RX LED:\u003c\/strong\u003e Flashes during communication with other rack modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCH Alarm LED:\u003c\/strong\u003e Illuminated when relay channel is in alarm state\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFCC Part 15\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-2 \/ -6-4 (EMC)\u003c\/li\u003e\n\u003cli\u003eEN 61010-1 (Electrical Safety)\u003c\/li\u003e\n\u003cli\u003eRoHS 2011\/65\/EU\u003c\/li\u003e\n\u003cli\u003eDNV GL, ABS (Maritime)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eInstallation and Safety\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eWARNING: HAZARDOUS VOLTAGE\u003c\/strong\u003e\u003cbr\u003e\nRisk of electric shock or burn. When connecting field wiring, conductors may be exposed, creating a shock hazard at high voltages.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWARNING: EXPLOSION HAZARD\u003c\/strong\u003e\u003cbr\u003e\nDisconnect power prior to servicing. Do not disconnect while circuit is live unless area is known to be non-hazardous. Consult manual prior to servicing.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How are the 16 relays organized?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Four groups of four channels. Each group is switch selectable for Normally De-energized (ND) or Normally Energized (NE) operation.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the difference between standard and low current relays?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Standard relays (silver contacts) require 100 mA @ 5 Vdc minimum. Low current relays (gold-plated) switch 1 mA @ 1 Vdc minimum for sensitive circuits.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the relay contact life?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e 10,000 cycles at rated load. Arc suppressor is installed as standard to extend contact life.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050454220932,"sku":"3500\/33-01-00","price":250.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_33-01-00.jpg?v=1784469438"},{"product_id":"bently-nevada-3500-42-01-02-seismic-monitor","title":"Bently Nevada 3500\/42-01-02 Seismic Monitor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eBently Nevada 3500\/42-01-02 (3500\/42M)\u003c\/strong\u003e is a 4-channel machinery protection monitor. It processes signals from proximity, velocity, and acceleration transducers to track radial vibration, thrust position, and eccentricity in real-time, ensuring the safety of critical rotating assets like turbines and compressors.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003e3500\/42-AA-BB Option Logic\u003c\/h3\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #003366;\"\u003eA (01):\u003c\/strong\u003e Includes the 128229-01 I\/O module with \u003cstrong\u003eInternal Terminations\u003c\/strong\u003e for direct, simplified field wiring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #003366;\"\u003eB (02):\u003c\/strong\u003e \u003cstrong\u003eATEX\/IECEx\/CSA (Class 1, Zone 2)\u003c\/strong\u003e certified for use in hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n            \u003cth style=\"border: 1px solid #dddddd; padding: 10px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #dddddd; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eInputs\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e4-channel Proximity, Velocity, or Accel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eAccuracy\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e±0.33% typical; ±1% maximum\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eFrequency\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e1 Hz to 4000 Hz (Programmable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eOutput\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e4–20 mA individual recorder outputs\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003ePower\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e7.7 Watts typical\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eGap Setup:\u003c\/strong\u003e Calibrate probes to \u003cstrong\u003e-10 Vdc\u003c\/strong\u003e for optimal linear range monitoring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Monitor the \u003cstrong\u003eOK LED\u003c\/strong\u003e for loop integrity and \u003cstrong\u003eBypass LED\u003c\/strong\u003e for trip suppression status.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Shielded cables are required to prevent EMI noise on seismic signals.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAdvanced Processing:\u003c\/strong\u003e Supports Smax and 1X\/2X vector filtering for deep diagnostics.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eRugged Design:\u003c\/strong\u003e Built for continuous operation in extreme temperatures (-30°C to +65°C).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e Fully compatible with 3500 racks and System 1 software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can different sensor types be mixed?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes, each of the four channels can be independently configured for different transducers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the \"M\" designation?\u003c\/strong\u003e\u003cbr\u003e\nA2: \"Multimode\" indicates advanced signal processing and diagnostic capabilities over legacy modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is an external terminal block needed?\u003c\/strong\u003e\u003cbr\u003e\nA3: No, the \u003cstrong style=\"color: #003366;\"\u003e3500\/42-01-02\u003c\/strong\u003e uses internal terminations for direct wiring.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050455367812,"sku":"3500\/42-01-02","price":339.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_42-01-02.jpg?v=1777798601"},{"product_id":"bently-nevada-3500-42-06-00-4-ch-proximitor-seismic-monitor","title":"Bently Nevada 3500\/42-06-00 | 4-Ch Proximitor Seismic Monitor","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong style=\"color: #003366;\"\u003e3500\/42-06-00\u003c\/strong\u003e is a versatile 4-channel Proximitor Seismic Monitor, a core component of the Bently Nevada 3500 Machinery Protection System. It is engineered to process signals from proximity, velocity, and acceleration transducers, specifically optimized for Velomitor sensor integration. This module provides essential monitoring for radial vibration, thrust, and eccentricity, delivering high-precision data to prevent catastrophic mechanical failures in turbines and compressors.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Module Type (Option 06):\u003c\/strong\u003e Features an I\/O module with internal barriers and internal terminations, specifically designed for 4 x Velomitor sensors. This integration streamlines cabinet design by eliminating external barrier requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Approval (Option 00):\u003c\/strong\u003e This specific configuration carries No Hazardous Area Approval (None), making it suitable for standard safe-area industrial installations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eInputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1 to 4 Proximity, Velocity, or Acceleration signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e7.7 Watts (Typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eWithin ±0.33% of full-scale (Typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eApproximately 100 ms or less\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOutput Signal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIndividual 4 to 20 mA per channel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eInternal Barrier Integration:\u003c\/strong\u003e The 06-type I\/O simplifies signal loops by integrating safety barriers, which reduces wiring points and increases overall system reliability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eVelocity II Filtering:\u003c\/strong\u003e Supports advanced signal conditioning including 1X and 2X vector filters for machine speeds between 60 and 100,000 cpm, ensuring precise vibration tracking during startup and steady-state.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eBuffered Outputs:\u003c\/strong\u003e Each channel features a front-panel coaxial connector (550 Ω impedance). These ports provide raw signals for easy connection to portable diagnostic analyzers without interrupting protective functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Protection:\u003c\/strong\u003e With a 100 ms update rate, the module ensures immediate response to transient vibration events, critical for preventing damage to rotating equipment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComprehensive Monitoring:\u003c\/strong\u003e Capable of dual-path monitoring (e.g., Vibration and Gap or Vibration and 1X Vector), allowing for a more detailed assessment of machine health.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Signal Conditioning:\u003c\/strong\u003e Uses 4-pole high-pass and 2-pole low-pass filters to eliminate high-frequency noise and provide stable, accurate data for safety interlocks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What sensor types are compatible with the 3500\/42-06-00?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: While configured with an I\/O optimized for 4 x Velomitor sensors, the main board is capable of accepting proximity, velocity, and acceleration signals across its four channels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Why choose internal terminations (Option 06)?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Internal terminations reduce the need for external terminal blocks, leading to a more compact installation and lower maintenance complexity in the rack cabinet.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is this module suitable for explosive environments?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: No, the \"00\" option indicates no hazardous area approval. For explosive atmospheres, you should select the \"01\" or \"02\" approval options.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050456416388,"sku":"3500\/42-06-00","price":315.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_42-06-00.jpg?v=1777808289"},{"product_id":"3500-42m-bently-nevada-176449-02-seismic-monitor","title":"3500\/42M | Bently Nevada 176449-02 Seismic Monitor","description":"\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n    The \u003cspan style=\"color: #00008B; font-weight: bold;\"\u003e176449-02\u003c\/span\u003e is a sophisticated \u003cstrong\u003e3500\/42M Proximitor Seismic Monitor\u003c\/strong\u003e designed to provide continuous, high-precision surveillance for industrial rotating machinery. This 4-channel module processes inputs from proximity probes, accelerometers, and velocity transducers to detect early signs of mechanical wear or instability. By integrating rapid fault detection with a 0.1-second alert delay, it safeguards critical equipment like turbines and compressors from costly damage and unplanned downtime.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px; margin-top: 30px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n            \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eInput Signal\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1 to 4 Proximity, Velocity, or Acceleration\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #fcfcfc;\"\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e7.7W Typical (8.5W Max @ 24V DC)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0.5 Hz to 10 kHz (±3 dB)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #fcfcfc;\"\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eMeasurement Range\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e0-25.4 mm\/s RMS (Velocity)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e4-20 mA Analog + RS-485 Modbus\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #fcfcfc;\"\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProtection Rating\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIP40 \/ NEMA 12 Compliant\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px; margin-top: 30px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eVersatile Transducer Support\u003c\/strong\u003e: Effortlessly monitors radial vibration, shaft absolute, and casing velocity using a wide range of industrial sensors.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact Protection\u003c\/strong\u003e: Optimized physical dimensions allow for high-density installation in 3500 series racks, saving valuable control room space.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSuperior Reliability\u003c\/strong\u003e: Built to withstand 95% non-condensing humidity and extreme storage temperatures, ensuring long-term stability in field locations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandard Compliance\u003c\/strong\u003e: Meets ATEX\/IECEx Zone 2 and ISO 10816 requirements, making it suitable for hazardous area applications globally.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px; margin-top: 30px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What probes are compatible with the 176449-02?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: The module is fully compatible with Bently Nevada 3300 XL 8mm Proximitors and utilizes the 176334-01 cable for secure, interference-free connectivity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How does the module assist in remote monitoring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Through its RS-485 Modbus digital interface, the module can transmit real-time vibration data directly to a Distributed Control System (DCS) or PLC for remote logging and analysis.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Can it be installed in different mounting configurations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the module supports both 35mm DIN rail mounting for easy integration and panel-mount installation for permanent cabinet fixtures.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050457563268,"sku":"176449-02","price":269.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/176449-02.jpg?v=1777813529"},{"product_id":"3500-42m-01-00-bently-nevada-proximitor-seismic-i-o","title":"3500\/42M-01-00 Bently Nevada Proximitor Seismic I\/O","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong style=\"color: #003366;\"\u003eBently Nevada 3500\/42M-01-00\u003c\/strong\u003e is a high-performance 4-channel monitor designed for critical machinery protection. It accepts inputs from proximity probes and seismic transducers to provide real-time monitoring of radial vibration, axial position, and casing absolute vibration. This module is essential for protecting turbines, compressors, and pumps in high-demand industrial environments.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Type:\u003c\/strong\u003e 3500\/42M Proximitor Seismic Monitor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eI\/O Module:\u003c\/strong\u003e 128229-01 (Internal Terminations)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approval:\u003c\/strong\u003e 00 (None\/Non-hazardous area)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Continuous machinery protection and alarm management\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ddd;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eInput Signal\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e1 to 4 Prox\/Seismic signals\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eAccuracy (Amplitude)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e±0.33% typical, ±1% maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003ePhase Accuracy\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e3 degrees maximum error\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003ePower Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e7.7 Watts (Typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eTransducer Supply\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e-24 Vdc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong\u003eGap Voltage\u003c\/strong\u003e for proximity probes should be calibrated to \u003cstrong\u003e-10.0 Vdc\u003c\/strong\u003e to ensure operation within the sensor's linear range. Cable shields must be grounded only at the 3500 rack to prevent ground loops. The \u003cstrong\u003e128229-01 I\/O module\u003c\/strong\u003e utilizes internal terminal strips for direct field wiring, streamlining rack installation.\n\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFalse Trip Protection:\u003c\/strong\u003e Built-in \"OK\" limit logic monitors transducer health to prevent accidental machine shutdowns.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Diagnostics:\u003c\/strong\u003e Full compatibility with System 1 software for orbit, trend, and spectral analysis.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Reliability:\u003c\/strong\u003e Designed to maintain 365\/24 protection for large-scale rotating assets.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the benefit of the 128229-01 I\/O module?\u003c\/strong\u003e\u003cbr\u003e\nA1: It features internal terminations, allowing field wires to connect directly to the module without external terminal blocks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module power my sensors?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, it provides a regulated -24 Vdc power supply to all compatible proximity and velocity transducers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is the 3500\/42M compatible with older racks?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, it is the modern replacement for legacy 3500\/42 monitors and integrates seamlessly with standard 3500 series backplanes.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050458677380,"sku":"3500\/42M-01-00","price":274.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_42M-01-00.jpg?v=1777809749"}],"url":"https:\/\/www.etowonauto.com\/ha\/collections\/bently-nevada-3500-series-monitoring-system.oembed?page=12","provider":"Etowon Auto","version":"1.0","type":"link"}