{"product_id":"schneider-tsxdsy16s5-modicon-discrete-output-module","title":"Schneider TSXDSY16S5 Modicon Discrete Output Module","description":"\u003ch2\u003eSchneider Electric TSXDSY16S5 Modicon Discrete Output Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #0066cc;\"\u003eSchneider Electric TSXDSY16S5\u003c\/strong\u003e | Discrete output module for the Modicon Premium and TSX Micro automation platforms. Provides 16 triac-protected outputs operating within 48-240V AC range. Integrated fast-blow fuses deliver short-circuit and overload protection at 5 A. Screw terminal block connection. Weight: 0.31 kg (0.68 lb).\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cp\u003e16 triac-protected discrete outputs. Output voltage 48-240V AC (EN\/IEC 61131-2), 41-264V range. 1 A current per channel. 12 A maximum current per module. Response time under 10 ms activation and deactivation. Ge-Mov output overvoltage protection. 5 A integrated fast-blow fuse for overload and short-circuit protection. Isolation resistance over 10 MOhm at 500 V. Dielectric strength 2000 V at 50\/60 Hz for 60 s. CE marked.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n    \u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eSchneider Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eTSXDSY16S5\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eTSX Micro PLCs \/ Modicon Premium\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDiscrete Output Number\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDiscrete Output Type\u003c\/td\u003e\n\u003ctd\u003eTriac protected\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDiscrete Output Voltage\u003c\/td\u003e\n\u003ctd\u003e48-240V AC (EN\/IEC 61131-2); 41-264V range\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent per Channel\u003c\/td\u003e\n\u003ctd\u003e≤ 1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eMaximum Current per Module\u003c\/td\u003e\n\u003ctd\u003e≤ 12 A\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResponse Time (Activation)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eResponse Time (Deactivation)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOvervoltage Protection\u003c\/td\u003e\n\u003ctd\u003eGe-Mov\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOverload Protection\u003c\/td\u003e\n\u003ctd\u003e5 A integrated fuse, fast blow\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eShort-Circuit Protection\u003c\/td\u003e\n\u003ctd\u003e5 A integrated fuse, fast blow\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIsolation Resistance\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eDielectric Strength\u003c\/td\u003e\n\u003ctd\u003e2000 V, 50\/60 Hz, 60 s\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e220 mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e0.85 W + (1 W x No. of outputs x current per module)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eElectrical Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eModule Format\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg (0.68 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eIP Degree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003ePollution Degree\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0°C to +60°C (32°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-25°C to +70°C (-13°F to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95% (operation); 5-95% (storage), non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eOperating Altitude\u003c\/td\u003e\n\u003ctd\u003e0-2000 m (0-6561 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProtective Treatment\u003c\/td\u003e\n\u003ctd\u003eTC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eStandards\u003c\/td\u003e\n\u003ctd\u003eIEC 61131-2, UL 508, CSA C22.2, 73\/23\/EEC, 89\/336\/EEC, 93\/68\/EEC\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eProduct Certifications\u003c\/td\u003e\n\u003ctd\u003eCE, ABS, RMRS, LR, GL, BV, DNV, RINA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd\u003eFrance\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\n\u003cp\u003eMount in Modicon Premium or TSX Micro PLC rack. Connect field wiring via screw terminal block. Verify supply voltage remains within 48-240V AC range. Observe current limits of 1 A per channel and 12 A per module. The integrated 5 A fast-blow fuse protects against overload and short circuits. Maintain IP20 enclosure and pollution degree 2 environment. Ensure operating temperature remains between 0°C and 60°C.\u003c\/p\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eTriac-protected outputs handle AC loads directly without external relays or contactors. Integrated fast-blow fuses protect each output group against short-circuit and overload conditions. Ge-Mov overvoltage protection extends module life in electrically noisy environments. High 10 MOhm isolation resistance and 2000 V dielectric strength ensure reliable operation. Marine certifications (GL, ABS, RINA, DNV, LR, BV, RMRS) enable use in shipboard and offshore applications. Compact 0.31 kg design saves panel space.\u003c\/p\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How many outputs does this module provide?\u003cbr\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e 16 triac-protected discrete outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the current rating per channel and per module?\u003cbr\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e 1 A per channel, with 12 A maximum per module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What protection features are integrated?\u003cbr\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e Ge-Mov overvoltage protection plus a 5 A fast-blow fuse for overload and short-circuit protection.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":67650474115204,"sku":"TSXDSY16S5","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/TSXDSY16S5.jpg?v=1792313926","url":"https:\/\/www.etowonauto.com\/fr\/products\/schneider-tsxdsy16s5-modicon-discrete-output-module","provider":"Etowon Auto","version":"1.0","type":"link"}