{"product_id":"mtl-instruments-mtl5053-h1-fieldbus-barrier","title":"MTL Instruments MTL5053 H1 Fieldbus Barrier","description":"\u003ch2\u003e\u003cstrong\u003eMTL5053 Fieldbus Hazardous Area Isolator\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5053\u003c\/strong\u003e from MTL Instruments extends 31.25kbit\/s H1 fieldbus networks into hazardous areas. This specialized interface provides both power and communication to fieldbus devices through signal conductors. Featuring an internal terminator and Fieldbus Foundation compliance, it offers a complete solution for industrial network expansion.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eMTL Instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u003cstrong\u003eMTL5053\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eFieldbus Hazardous Area Isolator\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e31.25kbit\/s (H1)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFieldbus Power:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e80mA maximum current\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eFieldbus Foundation Type 133\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDevice Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T4-T6\u003c\/span\u003e hazardous area\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eMTL5053\u003c\/strong\u003e maintains intrinsic safety for fieldbus networks\u003c\/li\u003e\n\u003cli\u003eIt enables safe operation of fieldbus devices in explosive atmospheres\u003c\/li\u003e\n\u003cli\u003eComprehensive certification for hazardous area installation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFieldbus Power Supply\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e18.4V ±2%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Impedance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e105Ω ±3%\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e80mA\u003c\/span\u003e for fieldbus devices\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e Determined by intrinsic safety requirements\u003c\/li\u003e\n\u003cli\u003eProvides power through fieldbus signal conductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eDigital Signal Transmission\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Rate:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e31.25kbit\/s H1 fieldbus\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e Meets Fieldbus Foundation standards\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Terminator:\u003c\/strong\u003e Switch-selectable on module top\u003c\/li\u003e\n\u003cli\u003eIdeal for installations with short safe-area bus lengths\u003c\/li\u003e\n\u003cli\u003eMaintains signal integrity in hazardous environments\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e135mA typical at 24V\u003c\/span\u003e with 80mA load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e2.3W typical at 24V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e2.6W at 35V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStatus Indicator:\u003c\/strong\u003e Green LED for power monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Horizontal DIN-rail on vertical surface recommended\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpacing:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10mm between adjacent units\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpacers:\u003c\/strong\u003e MTL MS010 spacers available for proper installation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature:\u003c\/strong\u003e Maximum 45°C for non-optimum orientation\u003c\/li\u003e\n\u003cli\u003eAdequate heat dissipation ensures reliable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety \u0026amp; Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250V AC\u003c\/span\u003e between all circuits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e22V\u003c\/span\u003e maximum for terminals 1-2\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e102Ω\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e216mA\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eUm = 250V rms or DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat fieldbus standard does the MTL5053 support?\u003c\/strong\u003e\u003cbr\u003eIt supports 31.25kbit\/s H1 fieldbus and complies with Fieldbus Foundation Type 133 requirements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow much power can it provide to fieldbus devices?\u003c\/strong\u003e\u003cbr\u003eIt delivers up to 80mA at 18.4V for fieldbus device power.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it include termination capability?\u003c\/strong\u003e\u003cbr\u003eYes, an internal terminator can be enabled via a switch on the module top.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the mounting requirements?\u003c\/strong\u003e\u003cbr\u003eFor optimal performance, mount on horizontal DIN-rail with 10mm spacing between units.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":51268266393732,"sku":"MTL5053","price":70.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MTL5053.jpg?v=1762685994","url":"https:\/\/www.etowonauto.com\/fr\/products\/mtl-instruments-mtl5053-h1-fieldbus-barrier","provider":"Etowon Auto","version":"1.0","type":"link"}