{"product_id":"ics-triplex-t8830-analogue-input-fta-40-channel-0-22ma","title":"ICS Triplex T8830 Analogue Input FTA 40 Channel 0-22mA","description":"\u003ch2 style=\"color: #005A9C;\"\u003eT8830 ICS Triplex Trusted 40 Channel Analogue Input FTA\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong style=\"color: #005A9C;\"\u003eT8830\u003c\/strong\u003e is a 40-channel analogue input Field Termination Assembly from ICS Triplex for the Trusted TMR System. Interfaces field devices generating 0-22mA signals with the T8431 Analogue Input Module. Each channel features individual 50mA fusing. Certified for Ord, HazLoc, ATEX, and IECEx.\u003c\/p\u003e\n\n\u003ch3\u003eCore Technical Advantages\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e40 Input Channels:\u003c\/strong\u003e High-density termination for up to 40 analogue field devices per FTA.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePer-Channel Fusing:\u003c\/strong\u003e Each channel protected by TR5 50mA fuse, limiting field loop current.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSmartSlot Support:\u003c\/strong\u003e Enables 'one to many' hot replacement of input modules (Version 1).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDual 24Vdc Field Supply:\u003c\/strong\u003e Redundant feeds commoned via diodes with green LED indication.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certified:\u003c\/strong\u003e Ord\/HazLoc\/ATEX\/IECEx approved for global deployment.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIndustry Standard:\u003c\/strong\u003e 2-wire field device connections on DIN rail compatible assembly.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\n\u003ctable style=\"width:100%; border-collapse: collapse; font-size:14px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color:#f0f0f0;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eT8830\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eDescription\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e40 Channel Analogue Input FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e18 - 32 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eInput Range\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e0 – 22 mA \/ channel\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eChannels\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eFuse\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eTR5, 50 mA (qty 40)\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eLoad Resistor\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e250 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eField Connection\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2-wire\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCertification\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eOrd \/ HazLoc \/ ATEX \/ IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eCompatible Module\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eT8431 Analogue Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n    \u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h3\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e DIN rail compatible. Install in Trusted TMR system cabinet. Follow ATEX\/IECEx hazardous area requirements.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Connect dual 24Vdc feeds to 5-way terminal block PWR TB. Check green LED for supply integrity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eField Wiring:\u003c\/strong\u003e Connect 2-wire field devices to 12-off 3-way terminal blocks and 2-off 2-way terminal blocks.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModule Interface:\u003c\/strong\u003e Connect to T8431 via 96-way SK1 socket. SmartSlot SK2 connector used for Version 1 only.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFuse Replacement:\u003c\/strong\u003e Use TR5 50mA fuses. Replace only when channel is de-energized.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eEngineering Advantages \u0026amp; Compatibility\u003c\/h3\u003e\n\n\u003cp\u003eDesigned for ICS Triplex Trusted TMR systems, compatible with T8431 Analogue Input Module. Per-channel 250Ω load resistor converts 0-22mA signals for direct module input. Individual fusing limits loop current and protects field wiring. Hazardous area certifications enable deployment in oil \u0026amp; gas, chemical, and power generation facilities.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical FAQs\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: What type of field devices connect to the T8830?\u003c\/strong\u003e\u003cbr\u003e\nA1: Supports 2-wire field devices generating 0-22mA analogue signals, such as pressure transmitters, temperature sensors, and position transducers.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the SmartSlot connector used for?\u003c\/strong\u003e\u003cbr\u003e\nA2: SK2 connector supports SmartSlot Version 1 for 'one to many' hot replacement. Not used with SmartSlot Version 2.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How do I check field power supply status?\u003c\/strong\u003e\u003cbr\u003e\nA3: Green LED on the FTA indicates presence of dual 24Vdc field power. No LED indicates power supply failure.\u003c\/p\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":52581222875268,"sku":"T8830","price":402.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/T8830-1.jpg?v=1785577004","url":"https:\/\/www.etowonauto.com\/fr\/products\/ics-triplex-t8830-analogue-input-fta-40-channel-0-22ma","provider":"Etowon Auto","version":"1.0","type":"link"}