{"product_id":"honeywell-cc-taix01-51308363-175-analog-input-module","title":"Honeywell CC-TAIX01 51308363-175 Analog Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eHoneywell CC-TAIX01 51308363-175\u003c\/strong\u003e operates as a high-density Analog Input Field Termination Assembly (IOTA) designed for the Experion Process Knowledge System (PKS) C300 controller. This premium module bridges field transmitters and your control system, delivering accurate signal conditioning and superior transient protection for critical industrial process loops.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technological Advantages\u003c\/h2\u003e\n\u003ch3\u003eRobust Isolation Architecture\u003c\/h3\u003e\n\u003cp\u003eThe hardware features 1500 VAC continuous galvanic isolation between field circuitry and internal logic, blocking voltage surges and eliminating ground-loop interference.\u003c\/p\u003e\n\n\u003ch3\u003eAdvanced Thermal Efficiency\u003c\/h3\u003e\n\u003cp\u003eLow power engineering minimizes thermal buildup. The unit draws only 0.320 Amps at 24 VDC, limiting total heat dissipation to 2.464 Watts.\u003c\/p\u003e\n\n\u003ch3\u003eActive Signal Protection\u003c\/h3\u003e\n\u003cp\u003eOnboard surge suppression and integrated low-pass filtering clean data streams by attenuating high-frequency electrical noise and EMI above 50 Hz.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #1a365d; color: #ffffff;\"\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eSpecification Parameter\u003c\/th\u003e\n      \u003cth style=\"padding: 10px; border: 1px solid #e2e8f0; text-align: left;\"\u003eValue \/ Operational Limit\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHoneywell\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCC-TAIX01\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003ePart Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e51308363-175\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eInput Channels\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e16 High-Level Analog Inputs\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eSignal Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e4 to 20 mA \/ 1 to 5 VDC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eCurrent Consumption\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0.320 Amps @ 24 VDC maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHeat Dissipation\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e2.464 Watts maximum\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eResolution \u0026amp; Accuracy\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e16-Bit Sigma-Delta \/ ±0.075% FS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003e0°C to +60°C (+32°F to +140°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f7fafc;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eHarsh Environment Protection\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #e2e8f0;\"\u003eISA-S71.04 Class G3 Conformal Coating\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEngineering Installation Guide\u003c\/h2\u003e\n\u003ch3\u003eCabinet Placement\u003c\/h3\u003e\n\u003cp\u003eMount the unit vertically or horizontally on standard Experion C300 rows. Maintain 50mm clearance above and below the assembly for natural convective airflow.\u003c\/p\u003e\n\n\u003ch3\u003eField Wiring Rules\n\u003c\/h3\u003e\u003cp\u003eUse 18 AWG (0.8 mm²) twisted, shielded pair cables. Ground the shield at a single point on the board bars. Keep low-voltage lines 300mm away from high-voltage AC cables.\u003c\/p\u003e\n\n\u003ch3\u003eHazardous Locations\u003c\/h3\u003e\n\u003cp\u003eIn Class I, Division 2 \/ Zone 2 setups, torque screw clamps to 0.5 Nm. Never swap or disconnect wiring while the 24 VDC power is active unless the area is verified safe.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eNative DCS Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe module provides plug-and-play auto-discovery within Experion PKS, eliminating manual driver configuration or firmware re-flashing.\u003c\/p\u003e\n\n\u003ch3\u003eEnvironmental Durability\u003c\/h3\u003e\n\u003cp\u003eStandard G3 conformal coating guards circuits against H2S, Cl2, and NH3 gases, preventing corrosive oxidation and failure.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Fault Redundancy\u003c\/h3\u003e\n\u003cp\u003eDual-cable routing supports sub-millisecond line switching, preventing unplanned process shutdowns if a main signal line breaks.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How does the module handle a broken field transmitter wire?\u003c\/strong\u003e\u003cbr\u003e\nA1: Integrated NAMUR NE43 burnout detection flags faults when current drops below 3.6 mA, triggering an immediate HMI alarm and moving the loop to a safe state.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this assembly supply loop power to field transmitters?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes. The board routes 24 VDC power directly to field terminals, delivering up to 25 mA per channel to run 2-wire transmitters without external power blocks.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What specific hardware metrics can be monitored online?\u003c\/strong\u003e\u003cbr\u003e\nA3: The DCS displays internal hardware temperature, supply rail limits (faulting below 21.6 VDC or above 28.8 VDC), and ADC converter health.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51884955926660,"sku":"51308363-175","price":241.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CC-TAIX01_51308363-175.jpg?v=1779545905","url":"https:\/\/www.etowonauto.com\/fr\/products\/honeywell-cc-taix01-51308363-175-analog-input-module","provider":"Etowon Auto","version":"1.0","type":"link"}