{"product_id":"ge-fanuc-ic200pns001-profinet-network-interface-versamax-series","title":"GE Fanuc IC200PNS001 Profinet Network Interface | VersaMax Series","description":"\u003ch2\u003e\u003cstrong\u003eEmerson IC200PNS001 VersaMax Profinet Network Interface Unit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eEmerson IC200PNS001\u003c\/strong\u003e (formerly GE Fanuc) is a Profinet network interface unit for the VersaMax series. It acts as a remote I\/O scanner, enabling distributed I\/O architecture for PACSystem RX3i, RX7i, and Series 90-70 controllers over a high-speed Profinet network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Emerson (formerly GE Fanuc), \u003cstrong style=\"color: #d35400;\"\u003eIC200PNS001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003eProfinet Remote I\/O Network Interface Unit (Scanner)\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e PACSystem \u003cstrong\u003eRX3i, RX7i\u003c\/strong\u003e, Series \u003cstrong\u003e90-70\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet Standard:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003eVersion 2.2, Class A IO-Device\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Data Capacity:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e2880 bytes\u003c\/strong\u003e discrete + \u003cstrong style=\"color: #2c3e50;\"\u003e2880 bytes\u003c\/strong\u003e analog (1440 in\/1440 out each)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupported I\/O Modules:\u003c\/strong\u003e Up to \u003cstrong style=\"color: #2c3e50;\"\u003e8\u003c\/strong\u003e VersaMax I\/O modules per node\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Ports:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e2 x RJ45\u003c\/strong\u003e with embedded switch\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Speed:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e10\/100 Mbps\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUpdate Rate:\u003c\/strong\u003e Configurable from \u003cstrong style=\"color: #2c3e50;\"\u003e1 ms to 512 ms\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Bits:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e32 input status\u003c\/strong\u003e and \u003cstrong style=\"color: #2c3e50;\"\u003e32 output control\u003c\/strong\u003e bits\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e3 W\u003c\/strong\u003e (0.6A @ 5VDC from backplane)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e0°C to 60°C\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e \u003cstrong style=\"color: #2c3e50;\"\u003e134 mm W x 132 mm H\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRequired Software:\u003c\/strong\u003e Proficy Machine Edition \u003cstrong style=\"color: #2c3e50;\"\u003eVersion 7.0 or later\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation \u0026amp; Packaging\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation:\u003c\/strong\u003e Mount the \u003cstrong\u003eIC200PNS001\u003c\/strong\u003e on a DIN rail and connect up to 8 VersaMax I\/O modules. Connect the module to your Profinet network using standard Ethernet cable (CAT5e or better) via the RJ45 ports. Configure the node's IP address and I\/O mapping in Proficy Machine Edition software.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging:\u003c\/strong\u003e Each \u003cstrong\u003eIC200PNS001\u003c\/strong\u003e module ships individually. We ship via reliable carriers such as FedEx, UPS, or DHL.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What controllers is this module compatible with?\u003c\/strong\u003e\u003cbr\u003eA: The \u003cstrong\u003eIC200PNS001\u003c\/strong\u003e is compatible with Emerson's \u003cstrong\u003ePACSystem RX3i and RX7i\u003c\/strong\u003e CPUs, as well as legacy \u003cstrong\u003eSeries 90-70\u003c\/strong\u003e controllers, when using Proficy Machine Edition version 7.0 or higher for configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the maximum network cable distance?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The maximum segment distance for standard Ethernet cable (CAT5e) is \u003cstrong\u003e100 meters\u003c\/strong\u003e. This distance can be extended using Ethernet switches or fiber optic media converters.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can I perform firmware updates on this module?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes, the \u003cstrong\u003eIC200PNS001\u003c\/strong\u003e includes a USB port specifically for firmware upgrades. This allows you to update the module's firmware in the field to access new features or improvements.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050824728708,"sku":"IC200PNS001","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200PNS001-1.jpg?v=1767882842","url":"https:\/\/www.etowonauto.com\/fr\/products\/ge-fanuc-ic200pns001-profinet-network-interface-versamax-series","provider":"Etowon Auto","version":"1.0","type":"link"}