{"product_id":"bently-nevada-330103-00-16-10-02-05-probe","title":"Bently Nevada 330103-00-16-10-02-05 Probe","description":"\u003ch2\u003eBently Nevada 330103-00-16-10-02-05 Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a5fb4;\"\u003e330103-00-16-10-02-05\u003c\/strong\u003e (also cataloged as the \u003cstrong\u003e330103\u003c\/strong\u003e 3300 XL 8 mm Proximity Probe, Metric) provides radial vibration and axial position measurement in 3300 XL machinery monitoring systems. It has a PPS probe tip, an AISI 303\/304 stainless steel case, an M10x1 thread, and a Miniature coaxial ClickLoc connector with standard cable at 1.0 m length. CSA, ATEX, and IECEx approvals are included. Probe cable weight is 323 g\/m.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"width: 40%; text-align: left; padding: 10px; border: 1px solid #ccc; background: #f5f5f5;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"width: 60%; text-align: left; padding: 10px; border: 1px solid #ccc; background: #f5f5f5;\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e330103-00-16-10-02-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3300 XL 8 mm Proximity Probe, Metric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eUnthreaded Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOverall Case Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e130 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTotal Length\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.0 m (3.3 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eConnector\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMiniature coaxial ClickLoc, standard cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAgency Approval\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCSA, ATEX, IECEx\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProbe Tip Material\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePolyphenylene sulfide (PPS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCase Material\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAISI 303 or 304 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCase Thread\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eM10x1, max. thread engagement 15 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNominal Probe DC Resistance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e7.59 +\/- 0.50 ohms at 1.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eLinear Range\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.25 to 2.3 mm (10 to 90 mils), approx. -1 to -17 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRecommended Gap Setting\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-9 Vdc [approx. 1.27 mm (50 mils)]\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temp (Standard Probe)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-52 deg C to +177 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eField Wiring\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.2 to 1.5 mm2 (16 to 24 AWG), 3 conductor shielded triad, max. 305 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProbe Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e323 g\/m (11.4 oz\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eGap Voltage and Signal Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe 330103 probe operates over a 2 mm (80 mils) linear range beginning at approximately 0.25 mm (10 mils) from the target and extending to 2.3 mm (90 mils), corresponding to approximately -1 to -17 Vdc. The recommended gap setting for radial vibration measurement is -9 Vdc, approximately 1.27 mm (50 mils). Nominal DC resistance from center conductor to outer conductor is 7.59 +\/- 0.50 ohms for the 1.0 m probe length. The probe seals differential pressure between tip and case with a Viton O-ring; probes are not pressure tested prior to shipment. Average Scale Factor changes less than 3 % when tested in 93 % humidity per IEC 68-2-3 for up to 56 days. Field wiring uses 3 conductor shielded triad cable, tinned, from 0.2 to 1.5 mm2 (16 to 24 AWG), with a maximum length of 305 m (1000 ft) between the Proximitor Sensor and the monitor; signal roll-off at high frequencies occurs with longer field wiring. Standard probe temperature range is -52 deg C to +177 deg C. Exposure below -34 deg C may cause premature failure of the pressure seal. With intrinsically safe zener barriers per drawing 141092 or galvanic isolators, the probe meets Class I, Zone 0 AEx\/Ex ia IIC T5...T1 Ga and Class I, Groups A-D, Class II, Groups E-G, Class III. With a nonincendive circuit per drawing 140979, it meets Class I, Zone 2 AEx\/Ex nA IIC T5...T1 Gc, Class I Division 2 Groups A-D, and Class I Zone 2 AEx\/Ex ec IIC T5...T1 Gc.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the recommended gap setting for radial vibration on the 330103-00-16-10-02-05?\u003cbr\u003eA: -9 Vdc, approximately 1.27 mm (50 mils).\u003c\/p\u003e\n\u003cp\u003eQ: What is the nominal probe DC resistance at 1.0 m?\u003cbr\u003eA: 7.59 +\/- 0.50 ohms from center conductor to outer conductor.\u003c\/p\u003e\n\u003cp\u003eQ: What agency approvals are included in the 05 option?\u003cbr\u003eA: CSA, ATEX, and IECEx approvals.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047720484996,"sku":"330103-00-16-10-02-05","price":163.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330103-00-16-10-02-05.jpg?v=1795524112","url":"https:\/\/www.etowonauto.com\/fr\/products\/bently-nevada-330103-00-16-10-02-05-probe","provider":"Etowon Auto","version":"1.0","type":"link"}