{"product_id":"abb-icsk20f1-fpr3327101r1202-remote-i-o-unit-16-di-16-do","title":"ABB ICSK20F1 FPR3327101R1202 Remote I\/O Unit 16 DI 16 DO","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eABB \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003eICSK20F1\u003c\/span\u003e FPR3327101R1202 Remote I\/O Unit\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eABB \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003eICSK20F1\u003c\/span\u003e is a remote I\/O unit with product ID FPR3327101R1202. It provides 16 digital inputs and 16 digital outputs. Communicates via Modbus TCP IP protocol. DIN rail mounted with IP20 protection. Designed for distributed control and industrial automation applications.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eProduct ID\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eFPR3327101R1202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eICSK20F1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eRemote I\/O Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInput Power\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e24V DC ±20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDigital Outputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModbus TCP IP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eProtection Class\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eMounting\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDIN Rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0.45 kg (1.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eClip onto DIN rail. Connect 24V DC power to terminals. Assign IP address via web interface. Wire inputs and outputs per pinout diagram. Allow 50mm clearance for ventilation and cable access.\u003c\/p\u003e\n\n\u003ch3\u003eWiring\u003c\/h3\u003e\n\u003cp\u003eUse 18 22 AWG stranded copper wire. Strip 8mm for terminal connections. Use shielded cable for network communication. Route I\/O cables separately from power lines. Label all field wires for maintenance.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e How to set IP address?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Use web browser to access default IP. Change subnet mask and gateway to match plant network. Cycle power after saving changes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Why outputs not responding?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Check 24V supply to unit. Verify PLC is writing to correct Modbus registers. Confirm output wiring not shorted to ground.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e Maximum cable length for inputs?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Keep I\/O cables under 30m for digital signals. For longer runs use shielded cable or interposing relays to maintain signal integrity.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050821320836,"sku":"FPR3327101R1202","price":166.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FPR3327101R1202.jpg?v=1784369651","url":"https:\/\/www.etowonauto.com\/fr\/products\/abb-icsk20f1-fpr3327101r1202-remote-i-o-unit-16-di-16-do","provider":"Etowon Auto","version":"1.0","type":"link"}