{"product_id":"1746-ni16v-slc-500-16-channel-voltage-input-allen-bradley","title":"1746-NI16V SLC 500 16-Channel Voltage Input Allen-Bradley","description":"\u003ch2 style=\"color: #333333;\"\u003eAllen-Bradley 1746-NI16V SLC 500 Analog Input Module\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color: #333333;\"\u003eAllen-Bradley 1746-NI16V\u003c\/strong\u003e is a 16-channel analog input module for SLC 500 systems. Supports ±10V, 1-5V, 0-5V, and 0-10V signal ranges. Features 16-bit resolution with Sigma-Delta conversion and programmable filter frequencies. Weight: 0.45 kg (0.99 lbs).\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; border: 1px solid #333333;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eParameter\u003c\/td\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSpecification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e1746-NI16V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eSeries\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eModule Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eAnalog Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eResolution\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eConversion Type\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003eSigma-Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eInput Signal Types\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e±10V, 1-5V, 0-5V, 0-10V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBandwidth\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e6-250 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eInput Filter Frequencies\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e6, 10, 20, 40, 60, 80, 100, 250 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eStep Response\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e9-630 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBackplane Current (5V)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBackplane Current (24V)\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eBackplane Power Consumption\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e2.425 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eIsolation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e500V AC for 1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eLED Indicators\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e5 green status LEDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-25°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e-40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"font-weight: bold; border: 1px solid #333333; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #333333; padding: 8px;\"\u003e0.45 kg (0.99 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #333333;\"\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e16 analog voltage input channels with 16-bit resolution\u003c\/li\u003e\n\u003cli\u003eSupports ±10V, 1-5V, 0-5V, and 0-10V signal ranges\u003c\/li\u003e\n\u003cli\u003eSigma-Delta conversion for high accuracy\u003c\/li\u003e\n\u003cli\u003e8 programmable input filter frequencies from 6-250 Hz\u003c\/li\u003e\n\u003cli\u003e500V AC isolation for 1 second\u003c\/li\u003e\n\u003cli\u003e5 green LED indicators for channel groups and module status\u003c\/li\u003e\n\u003cli\u003eUL listed, C-UL approved, CE compliant, Class I Division 2 certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #333333;\"\u003eInstallation Guidelines (Field Engineer Notes)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChassis Location:\u003c\/strong\u003e Install in any I\/O module slot except slot 0. Slot 0 is reserved for the controller. Module occupies single slot.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTerminal Block:\u003c\/strong\u003e Replacement terminal block is 1746-RT25G. Pre-wired cables available in 0.5, 1, 2.5, and 5.0 meter lengths.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommended Cable:\u003c\/strong\u003e Belden 8761 or equivalent shielded twisted pair. Maintain 50mm separation from power cables.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWiring:\u003c\/strong\u003e AIFM connector is 25-pin D-shell. Connect signal wires to appropriate terminals. Ground shield at the module end only.\u003c\/p\u003e\n\u003ch3 style=\"color: #333333;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1. What signal ranges does the 1746-NI16V support?\u003c\/strong\u003e\u003cbr\u003eA1. Supports ±10V, 1-5V, 0-5V, and 0-10V DC signal ranges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2. What is the resolution of this module?\u003c\/strong\u003e\u003cbr\u003eA2. The module provides 16-bit resolution with Sigma-Delta conversion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3. Can this module be installed in an expansion chassis?\u003c\/strong\u003e\u003cbr\u003eA3. Yes. The module can be installed in any available slot of the main chassis or expansion chassis except slot 0.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":52764103770244,"sku":"1746-NI16V","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1746-NI16V-3.jpg?v=1789218353","url":"https:\/\/www.etowonauto.com\/fr\/products\/1746-ni16v-slc-500-16-channel-voltage-input-allen-bradley","provider":"Etowon Auto","version":"1.0","type":"link"}