{"product_id":"hima-f3349-digital-input-module-sil-3-certified-hot-swap","title":"HIMA F3349 Digital Input Module SIL 3 Certified Hot-Swap","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cspan style=\"color:#00529b;font-weight:700;\"\u003eHIMA F3349\u003c\/span\u003e is a digital input module for H41q and H51q safety-related automation systems. As the direct replacement for the discontinued F3348, this module delivers SIL 3 certified signal acquisition with channel-by-channel fault isolation for maximum process availability.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e HIMA\u003cbr\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e F3349\u003cbr\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Digital Input Module\u003cbr\u003e\n\u003cstrong\u003eReplacement For:\u003c\/strong\u003e F3348 (discontinued)\u003cbr\u003e\n\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e H41q \/ H51q safety systems\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width:100%;border-collapse:collapse;font-size:13px;\"\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eHIMA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eF3349\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eDigital Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eReplacement For\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eF3348 (discontinued)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eH41q \/ H51q Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSafety Integrity Level\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eSIL 3 (IEC 61508)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eArchitecture\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e2oo4D \/ QMR (Quadruple Modular Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eModule Replacement\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eOnline hot-swap supported\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eProgramming System\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eELOP II (IEC 61131-3)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr style=\"background:#f0f4f8;\"\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eCountry of Origin\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding:6px;border:1px solid #ccc;\"\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation Guide\u003c\/h2\u003e\n\u003cp\u003eInstall the F3349 in standard 19-inch subracks designated for H41q or H51q systems. The module supports online replacement — defective units swap during active operation without stopping the safety loop. Configure all parameters using the ELOP II engineering tool with drag-and-drop functionality. Follow standard HIMA grounding and shielding protocols for backplane installation.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eChannel-by-channel fault isolation shuts down only the affected channel while all healthy channels continue operating, maximizing process availability. The F3349 integrates seamlessly into the 2oo4D\/QMR architecture of H41q\/H51q systems. Direct replacement for the discontinued F3348 eliminates re-engineering costs. Certified to SIL 3, AK 6, and Category 4 for demanding safety applications.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the F3349 a direct replacement for F3348?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e Yes, the F3349 replaces the discontinued F3348 in H41q\/H51q systems.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can the module be hot-swapped?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes, online replacement is supported without process interruption.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What safety certification does it carry?\u003c\/strong\u003e\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e SIL 3 (IEC 61508), AK 6, and Category 4 certified.\u003c\/p\u003e","brand":"HIMA","offers":[{"title":"Default Title","offer_id":52897097646212,"sku":"F3349","price":167.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/F3349_HIMA.jpg?v=1790421155","url":"https:\/\/www.etowonauto.com\/de\/products\/hima-f3349-digital-input-module-sil-3-certified-hot-swap","provider":"Etowon Auto","version":"1.0","type":"link"}