{"product_id":"ge-fanuc-ic697val318-series-90-70-analog-input-module-24v-dc","title":"GE Fanuc IC697VAL318 Series 90-70 Analog Input Module 24V DC","description":"\u003ch2 style=\"color: #1A237E; font-size: 22px; font-weight: bold; margin-bottom: 12px;\"\u003eGE Fanuc Series 90-70 Analog Interface Module (IC697VAL318)\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  The \u003cstrong style=\"color: #0D47A1;\"\u003e\u003cspan style=\"color: #0D47A1;\"\u003eGE Fanuc IC697VAL318\u003c\/span\u003e\u003c\/strong\u003e is a high-speed analog input\/interface module designed for the Series 90-70 programmable logic controller (PLC) system. Operating on a 24 to 30 VDC power supply, this robust industrial module accepts both voltage and current signals with an input resistance of 10 kΩ and delivers precision conversion accuracy of ±0.1% of full scale. Weighing approximately 0.45 kg (1.0 lb), it provides high-speed data acquisition with a 200 µs response time and features built-in RS-232 and RS-485 communication interfaces running at 9600 bps for reliable system integration.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eKey Performance Advantages\u003c\/h3\u003e\n\u003cp style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px;\"\u003e\n  Provides rapid 200 µs signal response and high-precision signal conversion for real-time industrial monitoring and process automation. Built for harsh factory floor environments, it maintains high operational stability across temperatures from -10°C to 60°C and non-condensing relative humidity levels from 0% to 90%.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 13px; color: #333333; margin-bottom: 15px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0; width: 40%;\"\u003eManufacturer \u0026amp; Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eGE Fanuc (Series 90-70)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePart \/ Catalog Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eIC697VAL318\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eInput Signal \u0026amp; Resistance\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eVoltage \/ Current Signals \/ 10k Ohm Input Resistance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eAccuracy \u0026amp; Response Time\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e±0.1% of Full Scale \/ 200 µs Response Time\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003ePower Requirements \u0026amp; Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e24 - 30 VDC \/ Approx. 0.45 kg (1.0 lb)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eCommunication Interface\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003eRS-232 \/ RS-485 Interface (9600 bps Data Transfer Rate)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #F5F5F5;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e-10°C to +60°C (14°F to 140°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #E0E0E0;\"\u003eRelative Humidity Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #E0E0E0;\"\u003e0% to 90% (Non-Condensing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eInstallation \u0026amp; Maintenance Guidelines\u003c\/h3\u003e\n\u003cul style=\"font-size: 14px; line-height: 1.5; color: #333333; margin-bottom: 15px; padding-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRack Installation:\u003c\/strong\u003e Align the module card edge with the designated slot in the Series 90-70 backplane chassis, pressing firmly into place until the card locks securely into the backplane connector.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower \u0026amp; Signal Wiring:\u003c\/strong\u003e Connect the 24-30 VDC external supply line ensuring correct polarity. Route analog voltage\/current input leads in shielded twisted-pair cables separate from high-voltage AC lines to prevent signal interference.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSerial Communication Setup:\u003c\/strong\u003e Configure RS-232 or RS-485 communication parameters to match the connected device at a default 9600 bps baud rate for seamless data exchange.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1A237E; font-size: 16px; font-weight: bold; margin-bottom: 8px;\"\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ1: Has EMC filter?\u003c\/strong\u003e\u003cbr\u003e\n  A1: N\/A (PLC analog module).\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ2: Key feature vs PF523?\u003c\/strong\u003e\u003cbr\u003e\n  A2: ±0.1% accuracy \u0026amp; 200 µs response time.\n\u003c\/p\u003e\n\u003cp style=\"font-size: 13px; line-height: 1.4; color: #333333; margin-bottom: 10px;\"\u003e\n  \u003cstrong\u003eQ3: Drives 3-phase motors?\u003c\/strong\u003e\u003cbr\u003e\n  A3: No, processes analog PLC signals.\n\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050814537860,"sku":"IC697VAL318","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC697VAL318-1.jpg?v=1786979751","url":"https:\/\/www.etowonauto.com\/de\/products\/ge-fanuc-ic697val318-series-90-70-analog-input-module-24v-dc","provider":"Etowon Auto","version":"1.0","type":"link"}