{"product_id":"allen-bradley-22c-d010n103-5hp-drive-0-400hz-pid","title":"Allen-Bradley 22C-D010N103 5HP Drive 0-400Hz PID","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eAllen-Bradley 22C-D010N103 PowerFlex 400 AC Drive\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003eAllen-Bradley 22C-D010N103\u003c\/b\u003e is a PowerFlex 400 adjustable frequency AC drive designed for fan and pump control. Delivering 5 HP (3.7 kW) continuous duty output, it operates on 380-480 V AC three-phase input with 0-400 Hz adjustable output frequency. Featuring ±0.5% speed control accuracy and a built-in PID controller, this fan-cooled drive manages 1 main motor plus 3 auxiliary motors with AutoSwap function. Weighing approximately 3.5 kg (7.7 lbs), it operates from 0°C to 40°C.\u003c\/p\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e22C-D010N103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Line\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003ePowerFlex 400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e5 HP (3.7 kW) Continuous Duty\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e380-480 V AC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOutput Frequency\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0-400 Hz Adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eControl Accuracy\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e±0.5% of Set Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0°C to 40°C (32°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCooling Method\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eFan-Cooled with Thermal Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eApprox. 3.5 kg (7.7 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eAdvanced Motor Management\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eControls 1 main motor plus 3 auxiliary motors\u003c\/li\u003e\n\u003cli\u003eAutoSwap function rotates motor workloads for equal wear\u003c\/li\u003e\n\u003cli\u003eBuilt-in PID controller for pressure and flow control\u003c\/li\u003e\n\u003cli\u003eMotor interlock prevents dead zones in systems\u003c\/li\u003e\n\u003cli\u003eAutomatic bypass for failed motors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003ePanel mount the drive with minimum 10 mm clearance space for airflow.\u003c\/li\u003e\n\u003cli\u003eUse copper conductors only. Ground wire minimum 10 AWG required.\u003c\/li\u003e\n\u003cli\u003eA disconnect switch must be visible and accessible near the drive.\u003c\/li\u003e\n\u003cli\u003eAllow 30 minutes cool-down before servicing the drive.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 22C-D010N103\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eManages up to 4 motors (1 main + 3 auxiliary) for multi-pump systems.\u003c\/li\u003e\n\u003cli\u003eAutoSwap equalizes motor wear, extending equipment life.\u003c\/li\u003e\n\u003cli\u003eBuilt-in PID eliminates external controllers for pressure\/flow regulation.\u003c\/li\u003e\n\u003cli\u003e0-400 Hz adjustable output supports diverse fan and pump applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e How many motors can the 22C-D010N103 control?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e The drive controls 1 main motor plus up to 3 auxiliary motors, with AutoSwap rotating workloads to equalize wear across all connected motors.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e What is the minimum clearance required for installation?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Maintain a minimum of 10 mm clearance around the drive for adequate airflow and cooling.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e What wire gauge is required for grounding?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Use a minimum 10 AWG copper conductor for the ground wire to ensure proper safety grounding.\u003c\/p\u003e\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca style=\"color: #0056b3; text-decoration: none; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050347921540,"sku":"22C-D010N103","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22C-D010N103.jpg?v=1791461792","url":"https:\/\/www.etowonauto.com\/de\/products\/allen-bradley-22c-d010n103-5hp-drive-0-400hz-pid","provider":"Etowon Auto","version":"1.0","type":"link"}