{"product_id":"6es7441-1aa04-0ae0-siemens-s7-400-cp-441-1-module","title":"6ES7441-1AA04-0AE0 | Siemens S7-400 CP 441-1 Module","description":"\u003ch3\u003eSIEMENS 6ES7441-1AA04-0AE0 SIMATIC S7-400 CP 441-1 Communication Module\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color:#0056b3;\"\u003eSIEMENS 6ES7441-1AA04-0AE0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCP 441-1\u003c\/strong\u003e Communication Module, operates as a single-channel point-to-point interface with variable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422\/485 connections within SIMATIC S7-400 platforms.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7441-1AA04-0AE0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCP 441-1 Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e800 g (approx.), interface module 100 g\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e25 mm x 290 mm x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC and 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent from Backplane Bus\u003c\/td\u003e\n\u003ctd\u003e600 mA max at 5 VDC (without interface module)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e0.3 W typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInterface Modules\u003c\/td\u003e\n\u003ctd\u003e20 mA (TTY), RS 422\/485 (X.27), RS 232C (V.24)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eInterface Module Consumption\u003c\/td\u003e\n\u003ctd\u003eTTY: 100 mA at 5 V, 45 mA at 24 V; RS 422\/485: 250 mA at 5 V; RS 232C: 100 mA at 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eNumber of Interfaces\u003c\/td\u003e\n\u003ctd\u003e1, variable\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShielded Cable Length\u003c\/td\u003e\n\u003ctd\u003e1000 m (TTY), 10 m (RS 232), 1200 m (RS 422\/485)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eTransmission Rate\u003c\/td\u003e\n\u003ctd\u003e38.4 kbit\/s max overall; 19.2 kbit\/s max on TTY\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eIntegrated Protocols\u003c\/td\u003e\n\u003ctd\u003e3964 (R), ASCII, Printer\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eSTEP 7 with own parameter assignment forms\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eMemory per Interface\u003c\/td\u003e\n\u003ctd\u003e1 to 5 kbyte parameters; 0 to 55 kbyte message texts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eVariable Interface Physics and Protocol Handling\u003c\/h3\u003e\n\n\u003cp\u003eUnit weight is approximately 800 g with an interface module at approximately 100 g, dimensions of 25 mm width, 290 mm height, and 210 mm depth. The CP 441-1 accepts interchangeable interface modules for 20 mA (TTY), RS 232C (V.24), and RS 422\/485 (X.27) physics. Shielded cable lengths are limited to 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422\/485. Transmission rate reaches 38.4 kbit\/s on RS 422\/485 and RS 232, and 19.2 kbit\/s on TTY across 3964 (R), ASCII, and printer drivers. Supported printers include HP-Deskjet, HP-Laserjet, IBM-Proprinter, and user-defined models. RK512 and reloadable customer-specific drivers are not supported. Backplane bus current draw is 600 mA maximum at 5 VDC without an interface module. Interface modules draw 100 mA at 5 V and 45 mA at 24 V for TTY, 250 mA at 5 V for RS 422\/485, and 100 mA at 5 V for RS 232C. Typical power loss is 0.3 W. Parameter memory requirements on the S7-CPU memory card are 1 to 5 kbyte for parameters and 0 to 55 kbyte for message texts. Configuration uses STEP 7 with dedicated parameter assignment forms. A configuration package is included on CD.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the weight and physical size of the 6ES7441-1AA04-0AE0?\u003c\/strong\u003e\u003cbr\u003e\nA: Approximately 800 g, with dimensions of 25 mm width, 290 mm height, and 210 mm depth. The interface module weighs approximately 100 g.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Is the RK512 protocol supported on this module?\u003c\/strong\u003e\u003cbr\u003e\nA: No. Integrated drivers cover 3964 (R), ASCII, and Printer only. RK512 and reloadable customer-specific drivers are not supported.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the maximum cable length for each interface type?\u003c\/strong\u003e\u003cbr\u003e\nA: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422\/485, all with shielded cable.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\n\u003cp\u003eInsert the module into the S7-400 rack and secure the mounting screws. Install the required interface module before energizing. Verify 5 VDC and 24 VDC supply availability. Route shielded cable within the limits of the installed interface physics: 1000 m for TTY, 10 m for RS 232, and 1200 m for RS 422\/485. Ground the shield at one end. Confirm the protocol and printer driver configuration in STEP 7 matches the connected device before commissioning. Verify the S7-CPU memory card has capacity for up to 55 kbyte of message texts. Install the configuration package from CD before parameter assignment.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67875598827652,"sku":"6ES7441-1AA04-0AE0","price":129.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/6ES7441-1AA04-0AE0.jpg?v=1793798821","url":"https:\/\/www.etowonauto.com\/de\/products\/6es7441-1aa04-0ae0-siemens-s7-400-cp-441-1-module","provider":"Etowon Auto","version":"1.0","type":"link"}