{"product_id":"6es7432-1hf00-0ab0-siemens-s7-400-sm-432-module","title":"6ES7432-1HF00-0AB0 Siemens S7-400 SM 432 Module","description":"\u003ch3\u003eSIEMENS 6ES7432-1HF00-0AB0 SIMATIC S7-400 SM 432 Analog Output Module\u003c\/h3\u003e\n\n\u003cp\u003eThe \u003cstrong style=\"color:#0056b3;\"\u003eSIEMENS 6ES7432-1HF00-0AB0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSM 432\u003c\/strong\u003e Analog Output Module, operates as an isolated 8-channel output module with 13-bit resolution and voltage\/current output ranges within SIMATIC S7-400 platforms.\u003c\/p\u003e\n\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\n\u003ctable\u003e\n  \u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7432-1HF00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eSiemens\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSM 432 Analog Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eSIMATIC S7-400\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eRated Load Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent from L+\u003c\/td\u003e\n\u003ctd\u003e200 mA max (no load), 400 mA max (rated load)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent from Backplane Bus\u003c\/td\u003e\n\u003ctd\u003e150 mA max at 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e9 W typ.\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13 bit including sign\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eConversion Time\u003c\/td\u003e\n\u003ctd\u003e420 us per channel; 300 us in all ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eVoltage Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 10 V, 1 to 5 V, -10 V to +10 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, -20 mA to +20 mA, 4 to 20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLoad Impedance (Voltage)\u003c\/td\u003e\n\u003ctd\u003eMin 1 kohm; capacitive load max 1 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eLoad Impedance (Current)\u003c\/td\u003e\n\u003ctd\u003eMax 500 ohm; 600 ohm with common-mode voltage below 1 V\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eShielded Cable Length\u003c\/td\u003e\n\u003ctd\u003eMax 200 m\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eDimensions (W x H x D)\u003c\/td\u003e\n\u003ctd\u003e25 mm x 290 mm x 210 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e650 g (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eOutput Ranges and Isolation Characteristics\u003c\/h3\u003e\n\n\u003cp\u003eUnit weight is approximately 650 g with dimensions of 25 mm width, 290 mm height, and 210 mm depth. The SM 432 provides 8 isolated analog outputs with 13-bit resolution including sign. Voltage output ranges are 0 to 10 V, 1 to 5 V, and -10 V to +10 V; current output ranges are 0 to 20 mA, -20 mA to +20 mA, and 4 to 20 mA. Voltage outputs are short-circuit protected with a maximum short-circuit current of 30 mA. Current outputs present a maximum no-load voltage of 19 V. Conversion time is 420 us per channel, with 300 us in all ranges. Settling time is 0.1 ms for resistive load, 3.5 ms for capacitive load, and 0.5 ms for inductive load. Operational error limit over the full temperature range is +\/-0.5% for voltage and +\/-1% for current. Basic error limit at 25 deg C is +\/-0.5% for both voltage and current. Potential separation exists between the channels and the backplane bus, and between the channels and load voltage L+, but not between individual channels. Isolation is tested at 2120 VDC between bus and L+\/M. No diagnostics function is provided.\u003c\/p\u003e\n\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What is the weight and physical size of the 6ES7432-1HF00-0AB0?\u003c\/strong\u003e\u003cbr\u003e\nA: Approximately 650 g, with dimensions of 25 mm width, 290 mm height, and 210 mm depth.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: Are the analog output channels isolated from each other?\u003c\/strong\u003e\u003cbr\u003e\nA: No. Potential separation is provided between the channels and the backplane bus and between the channels and load voltage L+, but not between individual channels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ: What load impedance does the module support for current and voltage outputs?\u003c\/strong\u003e\u003cbr\u003e\nA: Voltage outputs require a minimum of 1 kohm with capacitive load up to 1 uF. Current outputs support a maximum of 500 ohm, or 600 ohm when common-mode voltage is reduced below 1 V.\u003c\/p\u003e\n\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\n\u003cp\u003eInsert the module into the S7-400 rack and secure the mounting screws. Verify 24 VDC load voltage polarity before energizing; reverse polarity protection is provided. Route shielded analog output cables to a maximum of 200 m, with the shield grounded at one end. Confirm load impedance for voltage outputs is at least 1 kohm and for current outputs does not exceed 500 ohm. Verify conversion time and settling time against the loop response requirements before commissioning. Confirm isolation ratings against the field circuit potential before wiring.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":67875411722372,"sku":"6ES7432-1HF00-0AB0","price":135.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/6ES7432-1HF00-0AB0.jpg?v=1793719152","url":"https:\/\/www.etowonauto.com\/de\/products\/6es7432-1hf00-0ab0-siemens-s7-400-sm-432-module","provider":"Etowon Auto","version":"1.0","type":"link"}