{"title":"Featured Products","description":"","products":[{"product_id":"allen-bradley-1756-cn2-controllogix-controlnet-bridge-module","title":"Allen-Bradley 1756-CN2 ControlLogix ControlNet Bridge Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eAllen-Bradley 1756-CN2\u003c\/strong\u003e is a high-performance ControlNet bridge module designed for the rugged ControlLogix automation environment. Acting as a deterministic communications interface, this module establishes high-speed, real-time links between ControlLogix controllers and distributed I\/O racks, variable frequency drives, or other intelligent field platforms. Weighing a compact 0.26 kg (0.57 lbs), the single-slot 1756-CN2 routes scheduled and unscheduled peer-to-peer data over a reliable 5 Mbps ControlNet network line, ensuring deterministic timing that is completely unaffected by changes in node configuration or general network traffic overhead.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Capacity Network Bridging:\u003c\/strong\u003e Manages up to 131 total connections (including 100 dedicated Logix communication paths and separate unscheduled channels) to efficiently facilitate dense, factory-wide controller message routing.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDeterministic High-Speed Backplane:\u003c\/strong\u003e Utilizes a fixed 5 Mbps ControlNet communication rate to ensure time-critical interlocking data arrives precisely when expected, avoiding the jitter or packet collisions common in non-deterministic architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Environmental Engineering:\u003c\/strong\u003e Rated for operational shock conditions up to 30G and 2.0G of continuous mechanical vibration, this module delivers robust hardware endurance across an industrial temperature envelope of 0 to 60 degrees Celsius.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eAllen-Bradley \/ Rockwell Automation (ControlLogix Series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eModel Part Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1756-CN2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eGross Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.26 kg (0.57 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eInterface Network Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eControlNet coax-cable interface framework\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eCommunication Rate\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 Mbps fixed industrial network speed\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eMaximum Connections\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e131 total (100 dedicated Logix connections + unscheduled buffer allocations)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBackplane Slot Width\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSingle-slot physical format\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eBackplane Current Draw\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1100 mA at 5.1 VDC \/ 3 mA at 24 VDC bus lines\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eThermal \/ Power Dissipation\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5.6 Watts power loss \/ 19.1 BTU\/hour thermal dissipation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px; font-weight: bold;\"\u003eIndustrial HazLoc Ratings\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eTemperature Code T4A (North America) \/ IEC T4 (Europe)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eChassis Slot Installation:\u003c\/strong\u003e Isolate power to the local ControlLogix rack housing before mounting. Align the 0.26 kg communication hardware card inside the physical guide rails of any open slot, pushing straight back until the dual locking clips snap securely onto the structural frame.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCoaxial Tap Connectivity:\u003c\/strong\u003e Wire the ControlNet network link using standard RG-6 coaxial cables and approved ControlNet taps. Ensure that the active node switches on the front panel or configuration software are addressed uniquely before applying power to prevent network communication faults.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNetwork Update Interval (NUT) Tuning:\u003c\/strong\u003e Use RSNetWorx for ControlNet to properly schedule network data traffic. The 1756-CN2 allows you to prioritize time-sensitive interlocking signals via the scheduled data band while routing broad diagnostic diagnostic data via unscheduled slots.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does \"deterministic communication\" mean when utilizing the 1756-CN2 on ControlNet?\u003c\/strong\u003e\u003cbr\u003e\nA1: Deterministic communication means that the transmission time for your critical system data is mathematically guaranteed. Unlike standard Ethernet networks where packet collisions can cause unexpected execution delays, the 5 Mbps ControlNet frame provides a predictable schedule so that I\/O states updates are delivered reliably cycle after cycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does the 1756-CN2 module balance scheduled versus unscheduled traffic?\u003c\/strong\u003e\u003cbr\u003e\nA2: The module manages a total budget of 131 connections. It reserves 100 solid paths for scheduled Logix controller updates (like safety lines or remote I\/O loops), leaving the remaining buffer slots available for unscheduled actions like loading programs, checking web pages, or pulling non-critical hardware diagnostics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does the low 0.26 kg weight profile mean the hardware is prone to damage in heavy manufacturing settings?\u003c\/strong\u003e\u003cbr\u003e\nA3: No. The efficient 0.26 kg structural weight is the result of a compact, single-slot integration strategy. The internal electronics are fully engineered to withstand up to 30G of operational shock forces and 2.0G of industrial vibration without losing backplane connectivity.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047653179524,"sku":"1756-CN2","price":193.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1756-CN2.jpg?v=1784203978"},{"product_id":"allen-bradley-1756-cpr2-controllogix-controlnet-redundant-cable","title":"Allen-Bradley 1756-CPR2 ControlLogix ControlNet Redundant Cable","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eAllen-Bradley 1756-CPR2\u003c\/span\u003e ControlLogix ControlNet Cable Module\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  The module functions as a specialized communication link component engineered to interface high-speed ControlNet media lines inside an Allen-Bradley ControlLogix chassis. Occupying a single slot width, this intelligent media tap assembly supports deterministic 5 Mbps network networks, drawing 970 milliamps from the 5.1V DC backplane to manage redundant processing paths across distant physical locations using flexible 3-foot or 10-foot coaxial cabling configurations.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eAllen-Bradley (Rockwell Automation)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProduct Model \/ Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1756-CPR2\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eSystem Line Series\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eControlLogix System Base\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eComponent Interface Profile\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eControlNet Communication Cable Connection Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eNetwork Transmission Rate\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e5 Mbps high-speed deterministic bus profile\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBackplane Current Draw (5.1V)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e970 mA (milliamps) logic logic load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eBackplane Current Draw (24V)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1.7 mA (milliamps) auxiliary load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003ePower \u0026amp; Thermal Loading\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e5.1 Watts power dissipation | 17.4 BTU\/hour thermal dissipation loading\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eChassis Space Occupancy\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1-Slot width form factor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eSupported Cable Lengths\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e3 feet (0.91 meters) \/ 10 feet (3 meters) dedicated extensions\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eHardware Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e0.28 kg \/ 0.62 lbs typical structural assembly mass\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eTurn off all power feeding the target ControlLogix chassis rack before attempting to insert or remove communication components.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eAlign the circuit board track constraints of the 0.28 kg 1756-CPR2 module with the selected single-slot location guides.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003ePress the 0.28 kg assembly inward until the top and bottom structural locking tabs click firmly into place against the chassis frame.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eAttach the dedicated 3-foot or 10-foot ControlNet coaxial network connection links, securing the layout lines away from adjacent high-voltage AC cables to limit noise coupling.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ1: Why does the 1756-CPR2 link require a continuous 970 mA current draw from the 5.1V backplane?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The 970 mA load handles the high-frequency transceiver electronics needed to sustain a stable 5 Mbps transmission rate across long distances. This steady current consumption guarantees the signal amplitude remains clear and deterministic even when switching between primary and redundant network lines.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ2: How does the compact 0.28 kg physical form factor affect layout constraints in dense chassis spaces?\u003c\/strong\u003e\u003cbr\u003e\n  A2: A low 0.28 kg physical mass matches its single-slot width profile, allowing it to easily mount into any available location on the backplane without causing structural line stress. This lightweight design helps the module withstand environmental vibrations while producing a moderate 17.4 BTU\/hour thermal output.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 10px; color: #333; line-height: 1.5;\"\u003e\n  \u003cstrong\u003eQ3: Can standard off-the-shelf BNC cables substitute for the 3-foot or 10-foot ControlNet cables?\u003c\/strong\u003e\u003cbr\u003e\n  A3: No. The 1756-CPR2 module relies on specific characteristic impedance values found in certified 3-foot and 10-foot ControlNet cable variants. Relying on uncertified consumer coaxial lines can introduce impedance mismatches and data reflection anomalies, which degrade the 5 Mbps signal quality and trigger packet drops.\n\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047653376132,"sku":"1756-CPR2","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1756-CPR2.jpg?v=1782831575"},{"product_id":"2097-v33pr6-lm-servo-drive-allen-bradley-kinetix-350-12a","title":"2097-V33PR6-LM Servo Drive | Allen-Bradley Kinetix 350 12A","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley Kinetix 350 Single Axis Ethernet\/IP Servo Drive 2097-V33PR6-LM\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong style=\"color: #2e74b5;\"\u003e2097-V33PR6-LM\u003c\/strong\u003e is a high-power single-axis servo drive from the Kinetix 350 series. It delivers robust 3.0 kW motion control via EtherNet\/IP for demanding applications. This drive supports wide-range AC input and integrates critical safety and protection features like Safe Torque-Off.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Allen-Bradley \u003cstrong style=\"color: #2e74b5;\"\u003e2097-V33PR6-LM\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Kinetix 350 Single Axis Ethernet\/IP Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 80-132V AC (1-Phase), 80-264V AC (1\/3-Phase)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency:\u003c\/strong\u003e 48–62 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output:\u003c\/strong\u003e 12.0 A RMS \/ 17.0 A (0-Pk)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Output:\u003c\/strong\u003e 36.0 A RMS \/ 50.9 A (0-Pk)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power:\u003c\/strong\u003e 3.0 kW Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Backup:\u003c\/strong\u003e 20–26V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Safe Torque-Off (STO), Overvoltage \u0026amp; Short-Circuit Protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical \u0026amp; Physical Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal AC Input Current:\u003c\/strong\u003e 24.0 A RMS (120\/240V 1-Phase), 13.9 A RMS (240V 3-Phase)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInrush Current (Peak):\u003c\/strong\u003e 5.65 A (120\/240V), 11.3 A (240V)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9.37\" x 7.29\" x 3.06\" (238 x 185.1 x 77.7 mm approx.)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.2 lbs (1.9 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated EMC Filter:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInstallation Guidelines\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance:\u003c\/strong\u003e Minimum 3 mm (0.12\") on sides, 25 mm (1\") top\/bottom for airflow.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in a bonded, paint-free steel subpanel to minimize EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Protection:\u003c\/strong\u003e Use appropriately rated branch circuit breakers\/fuses per local codes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImportant:\u003c\/strong\u003e Do not remove connector pin covers during installation to prevent debris and shorts.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarning:\u003c\/strong\u003e Do not use sine-wave rated disconnect devices on the drive's PWM output.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the main benefit of the Safe Torque-Off feature?\u003c\/strong\u003e\u003cbr\u003eIt safely disables motor torque, allowing personnel to perform maintenance without fully disconnecting power, enhancing safety and compliance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes this drive require an external EMC filter?\u003c\/strong\u003e\u003cbr\u003eYes, since it lacks an integrated AC line filter, an external filter is often necessary to meet electromagnetic compatibility (EMC) standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan it be connected directly to a PanelView HMI?\u003c\/strong\u003e\u003cbr\u003eYes, it is designed to integrate seamlessly with Allen-Bradley PanelView terminals and other control system components over EtherNet\/IP.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047673757828,"sku":"2097-V33PR6-LM","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/2097-V33PR6-LM.jpg?v=1767704031"},{"product_id":"bently-nevada-21000-16-10-00-077-03-02-3300-xl-8mm-probe-assembly","title":"Bently Nevada 21000-16-10-00-077-03-02 3300 XL 8mm Probe Assembly","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2b579a; font-size: 1.1em;\"\u003eBently Nevada 21000-16-10-00-077-03-02\u003c\/strong\u003e is a professional-grade Proximity Probe Housing Assembly designed for critical machinery protection. This explosion-proof enclosure provides a secure environment for 3300 XL 8mm proximity probes, ensuring reliable vibration and position monitoring in hazardous industrial areas. Compliant with \u003cstrong\u003eAPI 670\u003c\/strong\u003e standards and featuring \u003cstrong\u003eCSA Type 4\u003c\/strong\u003e certification, this assembly is engineered to withstand extreme conditions while maintaining high-precision signal integrity for rotating equipment.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada (Baker Hughes)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cspan style=\"color: #2b579a;\"\u003e\u003cstrong\u003e21000-16-10-00-077-03-02\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Type:\u003c\/strong\u003e 3300 XL 8mm (1.0m \/ 39\" cable)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePenetration Depth:\u003c\/strong\u003e 7.7 Inches (Adjustable ±0.5\")\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Thread:\u003c\/strong\u003e 3\/4-14 NPT\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHousing Material:\u003c\/strong\u003e Aluminum body with 304 Stainless Steel sleeve (3.2mm thick)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e API 670, CSA Type 4, ATEX\/IECEx Zone 1 \u0026amp; 2\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003e1.1 kg (2.4 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e-50°C to +80°C (T4 Rated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eIngress Protection\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eIP66 \/ CSA Type 4\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eCable Diameter\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eSupports 1\/8\" to 3\/8\"\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eCircuit Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\" style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eSupports 24V DC intrinsically safe circuits; FCC Part 15 Compliant\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Design Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Precise Penetration:\u003c\/strong\u003e This specific configuration provides a \u003cstrong\u003e7.7-inch penetration depth\u003c\/strong\u003e, which can be fine-tuned by ±0.5 inches during installation. For deeper penetrations exceeding 12 inches, optional 300mm+ probe supports are recommended to ensure mechanical stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Corrosion \u0026amp; Vibration Resistance:\u003c\/strong\u003e The aluminum body is reinforced with a 304 stainless steel sleeve to prevent corrosion in harsh atmospheres. The package includes three anti-vibration grommets designed for 5\/16\" to 3\/8\" cables, ensuring that high-frequency machinery vibrations do not compromise the cable connections or signal quality.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Hazardous Area Certified:\u003c\/strong\u003e Designed for Zone 1 and Zone 2 environments, the 21000 series housing features dual-conduit ports and is fully trackable via laser-etched serial and part numbers. The assembly includes stainless steel locking washers to prevent loosening under operational stress.\u003c\/p\u003e\n\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe Bently Nevada 21000 series housing assembly is the industrial benchmark for proximity probe protection. By utilizing 3.2mm thick stainless steel for critical wear components and offering IP66-rated ingress protection, it ensures that sensitive 3300 XL transducers remain accurate over their entire service life. The inclusion of NPT thread reducers and cable seal grips in the standard package simplifies retrofitting and integration into existing monitoring systems.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the benefit of the CSA Type 4 rating?\u003c\/strong\u003e\u003cbr\u003e\nA1: The CSA Type 4 rating indicates the enclosure is explosion-proof and provides protection against windblown dust, rain, and hose-directed water, making it suitable for outdoor industrial use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the penetration depth be adjusted after the housing is mounted?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, the 21000-16-10-00-077-03-02 allows for an adjustment range of ±0.5 inches (approximately 12.7mm) to achieve the perfect gap between the probe tip and the target material.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is this housing compatible with non-3300 XL probes?\u003c\/strong\u003e\u003cbr\u003e\nA3: While specifically configured for the 3300 XL 8mm probe, the 21000 series is part of a modular system; however, signal integrity and warranty coverage are optimized when used with the factory-specified Bently Nevada transducers.\u003c\/p\u003e\n\n\u003ch2 id=\"download\"\u003eDownload Resource\u003c\/h2\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/21000-24701-Datasheet.pdf?v=1740714042\" target=\"_blank\" style=\"display: inline-block; padding: 10px 20px; background-color: #2b579a; color: #ffffff; text-decoration: none; border-radius: 4px; font-weight: bold;\"\u003e\n    Access Bently Nevada 21000-16-10-00-077-03-02 Technical Datasheet PDF\n  \u003c\/a\u003e\n\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047675134084,"sku":"21000-16-10-00-077-03-02","price":206.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-16-10-00-077-03-02.jpg?v=1776169809"},{"product_id":"21000-16-10-00-090-03-02-bently-nevada-8mm-proximity-probe","title":"21000-16-10-00-090-03-02 Bently Nevada 8mm Proximity Probe","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86c1; font-size: 1.1em;\"\u003eBently Nevada 21000-16-10-00-090-03-02\u003c\/strong\u003e is a high-performance, explosion-proof housing assembly designed for 8mm proximity probes. This complete solution provides precise non-contact vibration and position measurement for critical rotating machinery. Engineered for durability, it allows for probe maintenance or gap adjustment without requiring a machine shutdown, ensuring continuous operation in Class I, Division 1 and 2 hazardous environments.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003e21000-16-10-00-090-03-02\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Option:\u003c\/strong\u003e 3300 XL 8mm Proximity Probe (16)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 1.0 Meter \/ 39 Inches (10)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandoff:\u003c\/strong\u003e No Standoff Adapter (00)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePenetration Depth:\u003c\/strong\u003e 9.0 Inch \/ 229 mm (090)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFittings:\u003c\/strong\u003e Complete Fittings Package (03)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Thread:\u003c\/strong\u003e 3\/4-14 NPT (02)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eFrequency Response\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e0 to 10 kHz (±3dB)\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eMax Vibration\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e20g peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eTemperature\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e-50°C to +80°C\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eMaterial\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eAluminum \u0026amp; 304 SS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eCertification\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd colspan=\"3\" style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eCSA Approved, API 670 Standard, RoHS Compliant\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Gap Voltage Setting:\u003c\/strong\u003e Calibrate the probe gap to \u003cstrong\u003e-10.0 Vdc\u003c\/strong\u003e using a digital multimeter. This setting ensures the sensor operates within the optimal linear range for vibration monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Depth Adjustment:\u003c\/strong\u003e The \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003e21000-16-10-00-090-03-02\u003c\/strong\u003e\u003c\/span\u003e allows for a ±0.5 inch mechanical adjustment to achieve precise positioning relative to the shaft target.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Hazardous Area Safety:\u003c\/strong\u003e Ensure all NPT conduit entries are sealed with approved industrial sealant to maintain the integrity of the explosion-proof housing and CSA certification.\u003c\/p\u003e\n\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis \u003cspan style=\"color: #2e86c1;\"\u003e\u003cstrong\u003eBently Nevada 21000\u003c\/strong\u003e\u003c\/span\u003e series assembly is the industry standard for steam turbines, compressor stations, and paper mills. The 304 stainless steel sleeve provides superior protection against corrosion and moisture, while the robust housing handles high-vibration environments up to 20g peak. It integrates seamlessly with 3300 and 3300 XL Proximitor systems for high-reliability asset protection.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does this housing include the 8mm probe?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes, the \"16\" option in the model code confirms this assembly includes the 3300 XL 8mm proximity probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can I use this in wet or humid conditions?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, the aluminum body and stainless sleeve are designed to handle high humidity and corrosive industrial atmospheres.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Is the 9.0\" penetration depth suitable for all machines?\u003c\/strong\u003e\u003cbr\u003e\nA3: This depth is ideal for machines requiring deep-reach access. Always verify your casing thickness and internal clearance before installation.\u003c\/p\u003e\n\n\u003ch2 id=\"download\"\u003eDownload Resource\u003c\/h2\u003e\n\u003cp style=\"margin-top: 20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/21000-24701-Datasheet.pdf?v=1740714042\" target=\"_blank\" style=\"display: inline-block; padding: 10px 20px; background-color: #2e86c1; color: #ffffff; text-decoration: none; border-radius: 4px; font-weight: bold;\"\u003e\n    Access Detailed Product Specifications PDF\n  \u003c\/a\u003e\n\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047675199620,"sku":"21000-16-10-00-090-03-02","price":387.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-16-10-00-090-03-02.jpg?v=1775978316"},{"product_id":"22b-e012h204-allen-bradley-600v-10hp-variable-frequency-drive","title":"22B-E012H204 Allen-Bradley 600V 10HP Variable Frequency Drive","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eAllen-Bradley 22B-E012H204\u003c\/span\u003e PowerFlex 40 AC Drive\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  The Allen-Bradley 22B-E012H204 is a compact, high-performance PowerFlex 40 adjustable frequency AC drive engineered for precise motor speed and torque control in fans, conveyors, machine tools, and material handling systems. Operating on a 600V AC 3-phase supply, this Frame C drive delivers 12.0 A output current and 7.5 kW (10 HP) power. Designed as an IP20, NEMA\/UL Type Open replacement plate drive (heatsinkless), it features sensorless vector control, dynamic braking capabilities via an integral brake transistor, zero stacking mounting flexibility, and a total weight of approximately 2.80 kg.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eComplete Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555; font-weight: bold; color: #d32f2f;\"\u003e22B-E012H204\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProduct Family\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003ePowerFlex 40 Adjustable Frequency Drive\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eFrame Size \u0026amp; Enclosure\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eFrame C | Replacement Plate Drive (IP20, NEMA\/UL Type Open)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eInput Voltage \u0026amp; Phase\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e600V AC (460 - 600V AC operating range) | 3-Phase (50\/60 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOutput Power \u0026amp; Current Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e7.5 kW \/ 10 HP | 12.0 Amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eEstimated Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eApprox. 2.80 kg (6.17 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eControl Modes\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eVolts per Hertz (V\/Hz) \u0026amp; Sensorless Vector Control (SVC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eHuman Interface \u0026amp; Programming\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eIntegral Keypad with 4-Digit Display \u0026amp; 10 LED Status Indicators\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eStandard Communication\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eIntegral RS-485 \/ DSI Port\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOptional Network Interfaces\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eEtherNet\/IP, DeviceNet, ControlNet, PROFIBUS DP, LonWorks\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eInternal Features\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eBrake Transistor, PID, StepLogic, Removable MOV, Auto-Tune\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eEMC Filtering\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eNo CE Compliant Filter Installed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eMount the Frame C replacement plate drive on a flat, suitable heat-dissipating surface or DIN rail within a protected cabinet.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eConnect 600V AC 3-phase input lines to L1, L2, L3 and target motor leads to U, V, W using proper grounding techniques.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eUtilize the zero stacking design to optimize panel space when installing multiple PowerFlex 40 drives side-by-side.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eConfigure control parameters and perform motor auto-tuning via the built-in keypad or RS-485 PC interface.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ1: What does the replacement plate drive configuration mean?\u003c\/strong\u003e\u003cbr\u003e\n  A1: It is a heatsinkless IP20 unit designed to mount directly onto custom heatsinks or mounting plates inside cabinets.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ2: Can the 22B-E012H204 connect to EtherNet\/IP networks?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Yes, optional communication cards (EtherNet\/IP, DeviceNet, ControlNet, PROFIBUS) can be added via the DSI port.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ3: How does sensorless vector control improve performance?\u003c\/strong\u003e\u003cbr\u003e\n  A3: It dynamically adjusts output based on motor characteristics to maintain high torque levels across full speed ranges.\n\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047685619844,"sku":"22B-E012H204","price":137.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22B-E012H204.jpg?v=1785331102"},{"product_id":"2300-20-cn-bently-nevada-4-20ma-output-monitor","title":"2300\/20-CN Bently Nevada 4-20mA Output Monitor","description":"\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    The \u003cstrong style=\"color: #1a5276;\"\u003eBently Nevada 2300\/20-CN\u003c\/strong\u003e provides high-performance, cost-effective vibration monitoring for essential balance-of-plant (BOP) machinery. Specifically engineered for small-to-medium rotating equipment like motors, pumps, and fans, this dual-channel monitor excels in capturing critical mechanical data. By utilizing high-precision signal processing, the 2300\/20-CN ensures early detection of faults such as imbalance and bearing wear, delivering the industry-standard protection Bently Nevada is known for in a compact, standalone format.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\"\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n        \u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eFeature\u003c\/th\u003e\n        \u003cth style=\"padding: 12px; border: 1px solid #ddd; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eBently Nevada (Made in U.S.A)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eInput Channels\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e2-Channel Seismic (Accelerometers\/Velocity)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eAnalog Output\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eDual 4-20 mA (Isolated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCommunication\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eRS485 Modbus RTU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e18~36 VDC, 6.5 W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003eIP65 (Dust \u0026amp; Water Resistant)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n        \u003ctd style=\"padding: 12px; border: 1px solid #ddd;\"\u003e-30 °C to +65 °C (-22 °F to +149 °F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #2980b9; font-size: 18px;\"\u003eSeamless DCS Integration\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003eThe monitor converts complex seismic signals into dual isolated 4-20mA outputs. This allows your existing PLC or DCS to trigger alarms and shutdowns instantly, without the latency or complexity associated with proprietary rack software.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2980b9; font-size: 18px;\"\u003eEnhanced EMI Immunity\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003eEquipped with an internally isolated power architecture, the 2300\/20-CN effectively rejects electromagnetic interference caused by Variable Frequency Drives (VFDs) and large switchgear, ensuring stable and reliable readings in noisy industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2980b9; font-size: 18px;\"\u003eSmart Edge Diagnostics\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003eThe integrated RS485 Modbus RTU port transforms the hardware into an intelligent edge device. Maintenance teams can remotely poll detailed diagnostic data and trend machine health over time for superior predictive maintenance.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.8; color: #34495e;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Fixed-mount the IP65-rated housing near the machinery to minimize signal loss.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Utilize shielded twisted-pair cables, grounding the shield strictly at the monitor end to eliminate ground loops.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFault Logic:\u003c\/strong\u003e The 4-20mA loop is designed to drop below 4mA (typically to 2mA) to signal a \"Sensor Not OK\" status for rapid troubleshooting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    The 2300\/20-CN offers the same high-tier measurement algorithms found in Bently Nevada’s flagship 3500 series but at a fraction of the cost. Its rugged build handles extreme climates (-30°C to +65°C), making it the perfect upgrade path for replacing outdated vibration switches or simple analog transmitters with a digital-ready solution.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; font-size: 24px; padding-bottom: 5px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    \u003cstrong\u003eQ1: What does the \"CN\" suffix indicate?\u003c\/strong\u003e\u003cbr\u003e\n    A1: The \"CN\" designation signifies regional certification for the Chinese market. The hardware and technical performance are identical to the standard global 2300\/20 series.\n\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    \u003cstrong\u003eQ2: Is this compatible with proximity probes?\u003c\/strong\u003e\u003cbr\u003e\n    A2: No, this specific model is designed for seismic sensors (accelerometers\/velocity transducers). For eddy current probe applications, please consult our 1900\/65A or 3500 series inventory.\n\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #34495e;\"\u003e\n    \u003cstrong\u003eQ3: Does it require special software for basic 4-20mA monitoring?\u003c\/strong\u003e\u003cbr\u003e\n    A3: No. The 4-20mA outputs are hard-scaled, allowing for direct \"plug-and-play\" connection to any standard industrial controller.\n\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047692468356,"sku":"2300\/20-CN","price":348.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/2300_20-CN.jpg?v=1777212472"},{"product_id":"housing-assembly-bently-nevada-31000-16-10-00-154-00-02","title":"Housing Assembly Bently Nevada 31000-16-10-00-154-00-02","description":"\u003ch2 style=\"color: #2e86ab;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"color: #333; line-height: 1.6;\"\u003eThe \u003cstrong style=\"color: #003366;\"\u003e31000-16-10-00-154-00-02\u003c\/strong\u003e is a specialized, extended-reach proximity probe housing from Bently Nevada, specifically designed for deep installation applications. Featuring an impressive 15.4-inch (391mm) penetration depth, this housing is engineered to protect 3300 XL 8mm proximity probes in complex machinery architectures. The body is constructed from 35% glass-fiber reinforced conductive PPS thermoplastic, providing excellent electrostatic dissipation and corrosion resistance. With its IP66 and Type 4X certifications, this 1.2kg assembly ensures critical vibration monitoring data remains uninterrupted even in the harshest industrial environments.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eFull Part Number\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e31000-16-10-00-154-00-02\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eProbe Compatibility\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e3300 XL 8 mm (with connector)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eCable Length\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e1.0 Meter (39 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003ePenetration Depth\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e15.4 inches (Option 154)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eHousing Material\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eConductive PPS (35% Glass Fiber)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eIngress Protection\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eIP66 \/ CSA Type 4X\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd; font-weight: bold;\"\u003eMounting Thread\u003c\/td\u003e\n    \u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e3\/4-14 NPT\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul style=\"color: #333; line-height: 1.8;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Reach Configuration:\u003c\/strong\u003e The 15.4-inch penetration depth allows for precise probe positioning in large-scale turbines and compressors where standard housings cannot reach.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Material Durability:\u003c\/strong\u003e The glass-reinforced PPS composite provides structural rigidity and chemical resistance superior to standard plastics.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Compliance:\u003c\/strong\u003e Meets EN50014 standards for electrostatic dissipation, making it safe for use in explosive atmospheres.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Environmental Sealing:\u003c\/strong\u003e Equipped with dual Neoprene® O-rings to maintain a vacuum-tight seal against moisture and industrial contaminants.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp style=\"color: #333; line-height: 1.6;\"\u003eWhen installing the \u003cstrong style=\"color: #003366;\"\u003e31000-16-10-00-154-00-02\u003c\/strong\u003e, it is critical to verify that the internal machine clearance accommodates the full 15.4-inch penetration depth. The 3\/4-14 NPT mounting thread should be properly torqued to ensure a leak-proof fit. This specific \"00\" fittings option requires the installer to provide their own conduit connections. Periodically inspect the PPS housing for physical impacts; the unit is BASEEFA certified for impact resistance, but extreme mechanical stress should be monitored to ensure IP66 integrity.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2e86ab;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"color: #333;\"\u003e\u003cstrong\u003eQ1: Does this housing include the 3300 XL probe?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes, the \"16-10\" designation indicates that a 3300 XL 8mm probe with a 1.0-meter cable is included as part of this assembly.\u003c\/p\u003e\n\n\u003cp style=\"color: #333;\"\u003e\u003cstrong\u003eQ2: Can I use this in corrosive coastal environments?\u003c\/strong\u003e\u003cbr\u003e\nA2: Absolutely. The combination of 304\/303 stainless steel and PPS thermoplastic is highly resistant to salt spray and corrosion, as confirmed by its CSA Type 4X rating.\u003c\/p\u003e\n\n\u003cp style=\"color: #333;\"\u003e\u003cstrong\u003eQ3: What is the significance of the 15.4-inch penetration?\u003c\/strong\u003e\u003cbr\u003e\nA3: This length is chosen for applications where the sensor target (the shaft) is located deep within the machine casing, requiring a long protective sleeve to reach the measurement point.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047698432132,"sku":"31000-16-10-00-154-00-02","price":128.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/31000-16-10-00-154-00-02.jpg?v=1778250786"},{"product_id":"330103-00-05-50-02-cn-bently-nevada-3300-xl-8mm-probe","title":"330103-00-05-50-02-CN Bently Nevada 3300 XL 8mm Probe","description":"\u003ch2 style=\"font-size: 1.5em; color: #2c3e50; padding-bottom: 10px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330103-00-05-50-02-CN\u003c\/strong\u003e is a high-precision 8mm reverse-mount proximity probe from the 3300 XL series. This eddy current sensor provides non-contact displacement measurement for critical rotating machinery. With its CN-specific approval and rugged 304 stainless steel housing, it delivers sub-micron resolution for vibration and axial position monitoring in the most demanding industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 1.3em; color: #2c3e50; margin-top: 25px;\"\u003eTechnical Configuration\u003c\/h3\u003e\n\u003cul style=\"line-height: 1.6; list-style-type: disc; margin-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-00 (Unthreaded Length):\u003c\/strong\u003e 0 mm\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-05 (Case Length):\u003c\/strong\u003e 50 mm total threaded case.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-50 (Total Length):\u003c\/strong\u003e 5.0 Meters (16.4 ft).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-02 (Connector):\u003c\/strong\u003e ClickLoc Miniature Coaxial.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003e-CN (Approval):\u003c\/strong\u003e Country-specific Approval (China\/Global Compliance).\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size: 1.3em; color: #2c3e50; margin-top: 25px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px; border: 1px solid #ddd;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eLinear Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e2.0 mm (80 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eScale Factor\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e0 to 10 kHz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eOperating Temp\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003e-51°C to +177°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eCable Material\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eTeflon® coated coaxial\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eIngress Protection\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 12px;\"\u003eIP67 rated\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"font-size: 1.3em; color: #2c3e50; margin-top: 25px;\"\u003eInstallation Guide\u003c\/h3\u003e\n\u003cul style=\"line-height: 1.6; list-style-type: disc; margin-left: 20px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGap Setting:\u003c\/strong\u003e Calibrate the mechanical gap to reach \u003cstrong\u003e-9.0 VDC\u003c\/strong\u003e for center-range linearity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Use M10 x 1 threads with a maximum torque of \u003cstrong\u003e25 N·m\u003c\/strong\u003e.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem Matching:\u003c\/strong\u003e This 5m probe must be paired with a 5m Proximitor® sensor and extension cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"font-size: 1.3em; color: #2c3e50; margin-top: 25px;\"\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6;\"\u003eThe 330103 series utilizes advanced PPS (Polyphenylene Sulfide) polymer tips for superior resistance to caustic lubricants. Its ClickLoc connector system provides a secure, vibration-resistant electrical path, making it the industry standard for \u003cstrong\u003eTurbine Supervisory Instrumentation (TSI)\u003c\/strong\u003e and 3500 series monitoring racks.\u003c\/p\u003e\n\n\u003ch3 style=\"font-size: 1.3em; color: #2c3e50; margin-top: 25px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cdiv style=\"line-height: 1.6; margin-bottom: 10px;\"\u003e\n  \u003cp\u003e\u003cstrong\u003eQ1: What does the \"CN\" suffix signify?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The \"CN\" indicates Country-specific Approvals (typically China Ex or localized certification) while maintaining the global 3300 XL performance standards.\u003c\/p\u003e\n  \n  \u003cp\u003e\u003cstrong\u003eQ2: Is this probe compatible with older 3300 systems?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Yes, the 3300 XL system is designed to be backwards compatible with non-XL 3300 series components, though full XL performance requires an XL Proximitor.\u003c\/p\u003e\n  \n  \u003cp\u003e\u003cstrong\u003eQ3: How do I verify probe integrity?\u003c\/strong\u003e\u003cbr\u003e\n  A3: Use a multimeter to check the resistance between the center pin and the coaxial shield. A reading of 7.5 to 11.0 Ω is expected for a healthy 5m probe.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047709933700,"sku":"330103-00-05-50-02-CN","price":211.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330101-00-11-20-02-05_a50be3a9-90c0-414b-94fb-8a6c3c742e09.jpg?v=1777119369"},{"product_id":"bently-nevada-330101-00-19-10-02-05-proximity-probe","title":"Bently Nevada 330101-00-19-10-02-05 | Proximity Probe","description":"\u003ch2 style=\"color: #1a1a1a;\"\u003eBently Nevada 330101-00-19-10-02-05 3300 XL 8 mm Vibration Probe\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 20px;\"\u003e\u003cstrong style=\"color: #0066b3;\"\u003eBently Nevada 330101-00-19-10-02-05\u003c\/strong\u003e is a 3300 XL series 8 mm vibration probe with ±0.025 mm measurement precision. Features TipLoc and CableLoc designs, CSA\/ATEX\/IECEx approvals.\u003c\/p\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eCore Innovations\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px;\"\u003e\n\u003cli\u003eTipLoc Molding: 50% higher torsional stress resistance vs previous models\u003c\/li\u003e\n\u003cli\u003eCableLoc Pull Strength: 330 N (75 lbf) certified cable retention\u003c\/li\u003e\n\u003cli\u003eFluidLoc Option: Prevents leakage at 35 bar static pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003ePerformance Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 14px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePrecision\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e±0.025 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eTemperature Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-62°F to +500°F (extended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHumidity Tolerance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eASF variation less than 3% over 56 days @ 93% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCapacitance\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e69.9 pF\/m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eLinear Detection Range\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e80 mils @ 7.87 V\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e323 g\/m (11.4 oz\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eMaterial Specifications\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px;\"\u003e\n\u003cli\u003ePPS Probe Tip: Dimensional stability within ±0.01 mm @ 350°F\u003c\/li\u003e\n\u003cli\u003eStainless Steel Casing: 304\/316 SST options with 25 μm surface finish\u003c\/li\u003e\n\u003cli\u003eWeight Distribution: 11.4 oz\/m enables stable mounting up to 25,000 RPM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eCertifications\u003c\/h3\u003e\n\u003cul style=\"margin-bottom: 20px;\"\u003e\n\u003cli\u003eCSA\u003c\/li\u003e\n\u003cli\u003eATEX\u003c\/li\u003e\n\u003cli\u003eIECEx\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"color: #0066b3; margin-top: 20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the measurement precision?\u003c\/strong\u003e\u003cbr\u003eA1: ±0.025 mm with 80 mil linear detection range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the cable pull strength?\u003c\/strong\u003e\u003cbr\u003eA2: 330 N (75 lbf) with CableLoc design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What certifications are included?\u003c\/strong\u003e\u003cbr\u003eA3: CSA, ATEX, and IECEx for global hazardous area use.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047715471492,"sku":"330101-00-19-10-02-05","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330101-00-19-10-02-05.jpg?v=1783600047"},{"product_id":"bently-nevada-330101-00-28-10-02-00-proximity-probe","title":"Bently Nevada 330101-00-28-10-02-00 Proximity Probe","description":"\u003ch2 style=\"color: #1a365d; font-size: 13pt; margin-top: 0; margin-bottom: 8px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eThe \u003cstrong style=\"color: #1a365d;\"\u003eBently Nevada 330101-00-28-10-02-00\u003c\/strong\u003e is a high-performance proximity probe engineered for industrial machinery protection systems, offering precision shaft vibration, gap, and displacement monitoring. This eddy current sensor configuration features a 0.0-inch unthreaded length combined with a 2.8-inch overall case length. It comes equipped with a 1.0-meter (3.3 feet) integrated standard coaxial cable terminated with a miniature coaxial ClickLoc™ connector. Designed for general industrial deployments where hazardous area certifications are not required (-00 approval option), this probe operates reliably within a steady 12-24 V DC power supply voltage range. With an overall net hardware weight of 0.323 kg, it delivers exceptionally stable machinery diagnostics across pumps, fans, compressors, and generator sets.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 13pt; margin-bottom: 8px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 400px; margin-bottom: 12px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7fafc; border-bottom: 2px solid #cbd5e0;\"\u003e\n      \u003cth style=\"padding: 6px; text-align: left; font-weight: bold; color: #2d3748; font-size: 10pt; border: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 6px; text-align: left; font-weight: bold; color: #2d3748; font-size: 10pt; border: 1px solid #e2e8f0;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0; width: 35%;\"\u003eManufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003eBently Nevada\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eFull Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e330101-00-28-10-02-00\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eUnthreaded Case Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e0.0 inches (Fully threaded body)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e2.8 inches\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eTotal Cable Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e1.0 meter (3.3 feet) nominal\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003eConnector \u0026amp; Cable Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003eMiniature coaxial ClickLoc™ connector \/ Standard cable\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eMeasurement Sensitivity\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e0.4 V\/mm (linear tracking response)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eFrequency Response Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e1 Hz to 10 kHz (dynamic vibration capturing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e-40°C to +100°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eAgency Approvals\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003eNot required \/ Standard industrial zone profile (-00 option)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 6px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eComponent Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 6px; border: 1px solid #e2e8f0;\"\u003e0.323 kg (0.71 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 13pt; margin-bottom: 8px;\"\u003eInstallation \u0026amp; Handling Guidelines\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003e\u003cstrong\u003ePhysical Setup:\u003c\/strong\u003e Ensure the mounting bracket can comfortably house the 2.8-inch fully threaded casing. Take care not to twist or kink the standard FEP cable during insertion into the machine housing. Maintain a gentle cable loop profile to prevent damage to the core wire segments.\u003cbr\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e Fasten the miniature ClickLoc™ connector firmly to the downstream extension cable assembly. Verify that the system power supply provides a clean, regulated 12-24 V DC signal input to prevent unexpected measuring drifts or errors within the 1 Hz to 10 kHz monitoring loop.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 13pt; margin-bottom: 8px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2d3748;\"\u003eQ1: What is the measurement sensitivity profile of this proximity probe?\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 12px; padding-left: 8px;\"\u003eA1: The 330101-00-28-10-02-00 features a highly calibrated electrical sensitivity output of 0.4 V\/mm, allowing for exact monitoring of microscopic shaft clearances.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2d3748;\"\u003eQ2: What are the exact dimensions of this probe's threaded casing?\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 12px; padding-left: 8px;\"\u003eA2: This unit is configured with a 0.0-inch unthreaded length and a 2.8-inch overall case length, meaning the outer probe body is fully threaded across its entire span.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2d3748;\"\u003eQ3: Can this specific probe configuration be deployed in hazardous areas?\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 12px; padding-left: 8px;\"\u003eA3: No. The final \"00\" suffix indicates that agency approvals are not required, meaning this specific variant is built exclusively for general-purpose industrial applications.\u003c\/p\u003e\n\n\u003cp style=\"font-weight: bold; margin-bottom: 0;\"\u003eCommercial Contact Email: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #1a365d; text-decoration: underline;\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047716225156,"sku":"330101-00-28-10-02-00","price":106.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330101-00-28-10-02-00.jpg?v=1779713574"},{"product_id":"bently-nevada-330130-075-00-00-extension-cable","title":"Bently Nevada 330130-075-00-00 Extension Cable","description":"\u003ch2\u003eBently Nevada 330130-075-00-00 Extension Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Extension Cable | \u003cstrong\u003eCondition:\u003c\/strong\u003e New Original | \u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 Months\u003c\/p\u003e\n\u003ch3\u003eKey Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLength:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e7.5 meters (24.6 feet)\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Rating:\u003c\/strong\u003e 300V\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e-50°C to 150°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eImpedance:\u003c\/strong\u003e 75 Ohms\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e Double braided shield\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eJacket Material:\u003c\/strong\u003e PVC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 x \u003cstrong\u003e330130-075-00-00\u003c\/strong\u003e Extension Cable\u003c\/li\u003e\n\u003cli\u003eConnector protectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 months factory warranty\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCarriers:\u003c\/strong\u003e FedEx, UPS, DHL\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047729463428,"sku":"330130-075-00-00","price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330130-075-00-00.jpg?v=1774080714"},{"product_id":"proximity-sensor-330180-12-cn-bently-nevada","title":"Proximity Sensor 330180-12-CN Bently Nevada","description":"\u003ch2\u003eBently Nevada 330180-12-CN: 3300 XL Proximitor Sensor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330180-12-CN\u003c\/strong\u003e is a 3300 XL Proximitor Sensor made in USA with country-specific CN approval. This sensor accepts 5mm or 8mm probes with extension cable. Vibration specialists choose the \u003cstrong\u003e330180-12-CN\u003c\/strong\u003e for RFI immunity and flexible mounting options.\u003c\/p\u003e\n\u003ch2\u003eKey Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eManufacturer:\u003c\/span\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003ePart Number:\u003c\/span\u003e 330180-12-CN\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e 3300 XL Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOrigin:\u003c\/span\u003e Made in U.S.A\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eLength:\u003c\/span\u003e 12 = 1.0 meter (3.3 feet) system length\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e No mounting hardware included\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eApproval:\u003c\/span\u003e CN = Country Specific (China)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWeight:\u003c\/span\u003e 246 g (8.67 oz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003ePower Required:\u003c\/span\u003e -17.5 Vdc to -26 Vdc (non-incendive)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eWith Barriers:\u003c\/span\u003e -23 Vdc to -26 Vdc\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCurrent:\u003c\/span\u003e 12 mA maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eSensitivity:\u003c\/span\u003e \u0026lt;2 mV\/V change\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOutput Resistance:\u003c\/span\u003e 50 Ω\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eNote:\u003c\/span\u003e Operation above -23.5 Vdc reduces linear range\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eInput Compatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eProbe:\u003c\/span\u003e 3300-series 5mm or 3300 XL 8mm proximity probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eCable:\u003c\/span\u003e Extension cable included in system length\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eType:\u003c\/span\u003e Non-contacting sensor input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Ratings\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eOperating Temp:\u003c\/span\u003e -52°C to +100°C (-62°F to +212°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eStorage Temp:\u003c\/span\u003e -52°C to +105°C (-62°F to +221°F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eRFI\/EMI:\u003c\/span\u003e High immunity, CE approved\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eConduit:\u003c\/span\u003e No special shielding required\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eHousing:\u003c\/span\u003e Works in fiberglass enclosures\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Characteristics\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eSensor Material:\u003c\/span\u003e A308 aluminum\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eConnector Material:\u003c\/span\u003e Gold-plated brass or beryllium copper\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eTerminals:\u003c\/span\u003e SpringLoc, no tools needed\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eMounting:\u003c\/span\u003e DIN-rail or panel mount with 4-hole footprint\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #005a9c;\"\u003eIsolation:\u003c\/span\u003e Built into mounting base\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePackage Contents\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x Bently Nevada \u003cstrong\u003e330180-12-CN\u003c\/strong\u003e Proximitor Sensor\u003c\/li\u003e\n\u003cli\u003eFactory sealed anti-static packaging\u003c\/li\u003e\n\u003cli\u003eMade in USA original product\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the CN approval mean for 330180-12-CN?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: CN indicates country-specific approval for China. The \u003cstrong\u003e330180-12-CN\u003c\/strong\u003e meets regulatory requirements for installation in Chinese industrial facilities.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between 330180-12-CN and -BR?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Only the agency approval option differs. The \u003cstrong\u003e330180-12-CN\u003c\/strong\u003e has China-specific certification while electrical and mechanical specifications remain identical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this sensor mount on existing panels with older Proximitors?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The 4-hole mounting footprint matches older designs. The \u003cstrong\u003e330180-12-CN\u003c\/strong\u003e replaces legacy units without panel modifications.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047735984260,"sku":"330180-12-CN","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330180-12-CN-2.jpg?v=1772450825"},{"product_id":"330905-05-08-10-01-05-bently-nevada-3300-nsv-non-armored-probe","title":"330905-05-08-10-01-05 Bently Nevada 3300 NSv Non-Armored Probe","description":"\u003ch2 style=\"color: #1976d2; font-weight: bold; font-size: 1.6em; margin-bottom: 15px;\"\u003e\n  \u003cspan style=\"color: #1976d2; font-weight: bold;\"\u003eBently Nevada 330905-05-08-10-01-05\u003c\/span\u003e 3300 NSv Proximity Probe\n\u003c\/h2\u003e\n\n\u003cp style=\"font-size: 1em; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  The Bently Nevada 330905-05-08-10-01-05 is a high-precision 3300 NSv series eddy current proximity probe designed for critical machinery vibration and shaft position monitoring. Engineered with an M10x1 threaded AISI 304 stainless steel body, a polyphenylene sulfide (PPS) tip for superior chemical resistance, and a lightweight 1.0-meter 75Ω coaxial cable weighing approximately 0.08 kg, this non-armored transducer delivers accurate linear displacement measurements over a 1.5 mm range across extreme operating temperatures from -52°C to +177°C.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px; font-size: 0.95em;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333; width: 40%;\"\u003eBrand \/ Manufacturer\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eComplete Part Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555; font-weight: bold; color: #d32f2f;\"\u003e330905-05-08-10-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProduct Family \/ Model\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e3300 NSv Proximity Transducer System\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eCase Thread \u0026amp; Unthreaded Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eM10x1 Thread | 50 mm Unthreaded Length (-05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOverall Case Length\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e80 mm (-08)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eTotal Probe Length \u0026amp; Cable Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1.0 Meter \/ 39 in (-10) | 75Ω FEP Coaxial (Without Armor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eEstimated Net Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eApprox. 0.08 kg (0.18 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eConnector Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eMiniature Coaxial ClickLoc with Connector Protector (-01)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eLinear Measurement Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e1.5 mm \/ 60 mils (0.25 to 1.75 mm gap window)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eIncremental Scale Factor (ISF)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e7.87 V\/mm (200 mV\/mil) +12.5% \/ -20%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eFrequency Response Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e0 to 10 kHz (+0, -3 dB typical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eProbe Resistance (R\u003csub\u003ePROBE\u003c\/sub\u003e)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e4.2 ± 0.5 Ω (Center to Outer Conductor)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eMaterials (Tip \/ Case)\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eTip: Polyphenylene Sulfide (PPS) | Case: AISI 304 Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f9f9f9;\"\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eAgency Hazardous Area Approvals\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003eMultiple Approvals (-05)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold; color: #333;\"\u003eOperating \u0026amp; Storage Temperature\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; color: #555;\"\u003e-52°C to +177°C (-62°F to +351°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eQuick Installation Guide\u003c\/h3\u003e\n\u003cul style=\"padding-left: 20px; line-height: 1.5; color: #333; margin-bottom: 20px;\"\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eMount the M10x1 body into the machine housing (max 15 mm thread engagement, 7.5 N·m max case torque).\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eSet the target gap to 1.0 mm (40 mils) with a target diameter of at least 8.9 mm.\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eRoute the 1.0 m FEP coaxial cable maintaining a minimum bend radius of 25.4 mm (1.0 in).\u003c\/li\u003e\n  \u003cli style=\"margin-bottom: 6px;\"\u003eHand-tighten the ClickLoc connector (0.56 N·m max) and slip the protector over the connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #1976d2; font-weight: bold; font-size: 1.3em; margin-top: 20px; margin-bottom: 10px;\"\u003eTechnical FAQs\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ1: Why use a PPS tip material?\u003c\/strong\u003e\u003cbr\u003e\n  A1: It provides superior chemical resistance in harsh process compressor environments.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ2: Is it compatible with 3300 RAM systems?\u003c\/strong\u003e\u003cbr\u003e\n  A2: Yes, it is fully mechanically and electrically interchangeable with 3300 RAM hardware.\n\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 8px; color: #333; line-height: 1.4;\"\u003e\n  \u003cstrong\u003eQ3: What is the recommended probe gap setting?\u003c\/strong\u003e\u003cbr\u003e\n  A3: The recommended installation gap is 1.0 mm (40 mils) from the target shaft.\n\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047891042436,"sku":"330905-05-08-10-01-05","price":154.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330905-05-08-10-01-05.jpg?v=1785329271"},{"product_id":"3500-15-133292-01-bently-nevada-low-voltage-dc-power-supply","title":"3500\/15 133292-01 Bently Nevada Low Voltage DC Power Supply","description":"\u003ch2 style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 133292-01 Low Voltage DC Power Supply\u003c\/h2\u003e\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong style=\"color: #2c6e9e;\"\u003eBently Nevada 3500\/15 133292-01\u003c\/strong\u003e is a low voltage DC power supply module for 3500 rack systems. Input voltage 20 to 30 V DC. Full rack current draw 11 A maximum. Two half-height slots allow redundant power supply configuration. Module weight 1.39 kg.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left; width: 40%;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Number\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e3500\/15 133292-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eLow Voltage DC Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e20 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eFull Rack Current Draw\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e11.0 A maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMinimum Loading\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eNo minimum rack load required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +150°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #fff;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e120.7 x 50.8 x 251.5 mm (4.75 x 2.0 x 9.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background: #f0f0f0;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.39 kg (3.06 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow voltage DC input 20 to 30 V DC\u003c\/li\u003e\n\u003cli\u003e11 A maximum full rack current draw\u003c\/li\u003e\n\u003cli\u003eTwo half-height slots for redundant power supplies\u003c\/li\u003e\n\u003cli\u003eNo minimum rack load required\u003c\/li\u003e\n\u003cli\u003eUnder-voltage does not harm supply or PIM\u003c\/li\u003e\n\u003cli\u003eOver-voltage causes fuse to open on PIM\u003c\/li\u003e\n\u003cli\u003eSupply OK front panel LED indicator\u003c\/li\u003e\n\u003cli\u003eDNV GL and ABS maritime certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRack Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwo half-height slots on left side of rack\u003c\/li\u003e\n\u003cli\u003eEach slot accommodates one power supply\u003c\/li\u003e\n\u003cli\u003eBoth slots can hold power supplies simultaneously for redundancy\u003c\/li\u003e\n\u003cli\u003ePower Input Module (PIM) located directly behind associated power supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the input voltage range and full rack current draw?\u003c\/strong\u003e\u003cbr\u003eA1: 20 to 30 V DC input. Full rack current draw 11.0 A maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What are the power supply dimensions and weight?\u003c\/strong\u003e\u003cbr\u003eA2: Dimensions 120.7 x 50.8 x 251.5 mm. Weight 1.39 kg.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can two power supplies be installed for redundancy?\u003c\/strong\u003e\u003cbr\u003eA3: Yes. Both half-height slots can hold power supplies simultaneously for redundant configuration.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899005060,"sku":"133292-01","price":185.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15_133292-01.jpg?v=1783249602"},{"product_id":"bently-nevada-3500-15-04-04-00-power-supply-15w","title":"Bently Nevada 3500\/15-04-04-00 Power Supply 15W","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eBently Nevada 3500\/15-04-04-00 Power Supply Module\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eBently Nevada 3500\/15-04-04-00\u003c\/strong\u003e is a low voltage DC power supply module for 3500 Series machinery monitoring systems. Provides stable 15W output with 85% efficiency and dual slot redundancy. Designed for harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e20-30 Vdc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOutput Power\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e15W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eEfficiency\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eRipple Noise\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e50 mV peak-to-peak\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eEnvironmental Limits\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-30°C to +65°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eDual low voltage slots for system redundancy\u003c\/li\u003e\n\u003cli\u003ePrevents unexpected machine shutdowns\u003c\/li\u003e\n\u003cli\u003eBuilt for harsh industrial environments\u003c\/li\u003e\n\u003cli\u003eNo tools required for module swap\u003c\/li\u003e\n\u003cli\u003eProtects sensitive vibration sensors from power dips\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How do I install the 3500\/15-04-04-00 in the rack?\u003c\/strong\u003e\u003cbr\u003eA1: Slide the module into the left-side half-height slot until it clicks. Secure with the two captive screws. For redundancy, install a second unit in the adjacent slot. No power-down required for hot-swap.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the recommended wiring for DC input?\u003c\/strong\u003e\u003cbr\u003eA2: Use 14-16 AWG twisted pair for DC input. Connect positive to pin 1, negative to pin 2. Keep cable length under 3 meters to minimize voltage drop. Tighten terminal screws to 0.5 Nm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How do I verify proper operation after installation?\u003c\/strong\u003e\u003cbr\u003eA3: Check the Supply OK LED on the front panel. Green indicates normal. If LED is off, verify input voltage is between 20-30Vdc and polarity is correct. Measure output at test points before connecting load.\u003c\/p\u003e\n\n\u003cp style=\"margin-top:20px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\" style=\"display:inline-block; background-color:#0066b3; color:white; padding:10px 20px; text-decoration:none; border-radius:4px;\"\u003eDownload Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899299972,"sku":"3500\/15-04-04-00","price":165.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-04-04-00.jpg?v=1783746480"},{"product_id":"bently-nevada-3500-22-01-03-00-tdi-module-ethernet-i-o","title":"Bently Nevada 3500\/22-01-03-00 TDI Module Ethernet I\/O","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eBently Nevada 3500\/22M Transient Data Interface Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22M TDI Module\u003c\/b\u003e delivers high-speed transient data capture for critical turbomachinery. It captures waveform snapshots and event-triggered records, enabling advanced diagnostics for gas turbines, compressors, and steam turbines. This module serves as the communication gateway between the 3500 rack and plant management systems, ensuring continuous monitoring and predictive maintenance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eOrdering Code Configuration\u003c\/h3\u003e\n\u003cp\u003eThe \u003cb style=\"color: #0056b3;\"\u003e3500\/22M\u003c\/b\u003e part number follows this structure: \u003cb style=\"color: #0056b3;\"\u003e3500\/22-AA-BB-CC\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eAA – Transient Data Interface Type:\u003c\/b\u003e 01 = Standard (for standard monitoring applications)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eBB – I\/O Module Type:\u003c\/b\u003e 01 = 10Base-T\/100Base-TX Ethernet, 02 = 100Base-FX Fiber Optic, 03 = Ethernet with gold-plated OK relay, 04 = Fiber with gold-plated OK relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cb style=\"color: #0056b3;\"\u003eCC – Agency Approval:\u003c\/b\u003e 00 = None, 01 = CSA\/NRTL\/C (Class 1 Div 2), 02 = Multi (CSA, ATEX, IECEx)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eModule Dimensions (TDI)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 241.8 mm (9.50 x 0.96 x 9.52 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Dimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e241.3 x 24.4 x 99.1 mm (9.50 x 0.96 x 3.90 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eTDI Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.91 kg (2.0 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eI\/O Module Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.20 kg (0.44 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-30°C to +65°C (-22°F to +149°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +85°C (-40°F to +185°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eHumidity (non-condensing)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Powered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e38 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eBattery Life (Unpowered TDI @50°C)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e12 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eInstall the TDI module in a full-height front slot; the matching I\/O module occupies one full-height rear slot.\u003c\/li\u003e\n\u003cli\u003eUse twisted-pair shielded cables for Ethernet connections; maintain a minimum bend radius of 10x cable diameter.\u003c\/li\u003e\n\u003cli\u003eFor fiber optic variants (100Base-FX), clean connectors with lint-free wipes and inspect for \u0026lt; 0.5 dB loss.\u003c\/li\u003e\n\u003cli\u003eWhen replacing a legacy 3500\/22, ensure the firmware revision is updated to support the new I\/O options.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 3500\/22M\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eProvides buffered transient data for post-event analysis and predictive trending.\u003c\/li\u003e\n\u003cli\u003eSeamless integration with System 1® software and DCS\/PLC via Modbus or OPC.\u003c\/li\u003e\n\u003cli\u003eExtended temperature range and conformal coating options for harsh environments.\u003c\/li\u003e\n\u003cli\u003eBackward compatible with existing 3500 racks while offering faster Ethernet throughput.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e How to verify correct Ethernet communication after installation?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e Ping the assigned IP from the engineering workstation. Check link LED status on both the I\/O module and switch. If using fiber, verify light levels with a power meter – should read between -20 and -14 dBm for multimode.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e What is the proper grounding procedure for the I\/O module?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e Connect the rear slot ground lug directly to the rack's earth ground bus. Use 4 mm² (AWG 11) stranded wire. Ensure the Ethernet cable shield is grounded only at the switch end to avoid ground loops.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e Battery replacement steps without losing configuration?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Keep the 3500 rack powered during battery swap. Locate the 3V lithium coin cell on the TDI board. Remove old cell and insert new within 2 minutes – the supercapacitor holds memory for up to 30 minutes. Re-initialize time\/date after replacement.\u003c\/p\u003e\n\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca style=\"color: #0056b3; text-decoration: none; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-22.pdf?v=1740033909\" style=\"display: inline-block; background-color: #0056b3; color: #ffffff; padding: 10px 20px; text-decoration: none; border-radius: 4px; font-weight: bold;\" target=\"_blank\"\u003eDownload Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51047899562116,"sku":"3500\/22-01-03-00","price":325.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_22-01-03-00.jpg?v=1783848702"},{"product_id":"abb-pm858k02-redundant-process-controller-kit","title":"ABB PM858K02 Redundant Process Controller Kit","description":"\u003ch2\u003e\u003cstrong\u003eABB PM858K02 Redundant Process Controller Kit\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e6c80;\"\u003e3BSE082896R1 (PM858K02)\u003c\/span\u003e\u003c\/strong\u003e is a complete ABB AC 800M standard redundant controller kit. This package provides everything needed to establish a highly available dual-CPU system for non-safety process control. It includes all essential hardware for installation and redundancy setup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Kit Contents \u0026amp; Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e ABB \u003cstrong\u003ePM858K02\u003c\/strong\u003e (3BSE082896R1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackage Contents:\u003c\/strong\u003e 2x PM858 CPUs, 2x TP830 Baseplates, 2x TB807 Terminators, CEX-bus \u0026amp; RCU-Link cables, 2x Backup Batteries.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Yes, pre-configured for CPU redundancy with \u0026lt;10 ms switchover.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU Specs:\u003c\/strong\u003e MPC866 @ 33 MHz, 16 MB RAM (7.1 MB for application).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Standard process control (Not for High Integrity\/SIL applications).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e 2x Ethernet, 2x RS-232C ports per controller.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Easy DIN rail slide \u0026amp; lock mechanism.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Data, Compatibility \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eKit Weight:\u003c\/strong\u003e 2700 grams (approximately 5.95 lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions per Unit:\u003c\/strong\u003e 119 mm x 186 mm x 135 mm (W x H x D).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Feature:\u003c\/strong\u003e Each baseplate has a unique hardware Ethernet address for identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Requires System 800xA 6.0.2 or Compact Control Builder 6.0.0-1 and later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, cULus (Class 1, Zone 2), ISA Secure, RoHS, WEEE, marine (DNV-GL).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e +5°C to +55°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the main advantage of this kit over a single PM858?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; The \u003cstrong\u003ePM858K02\u003c\/strong\u003e kit provides two complete controller units and all interconnecting cables, offering a ready-to-install redundant system for critical processes requiring high uptime.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can this system be used for safety applications?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; No. This kit is for standard process control redundancy. Safety applications require the High Integrity PM857\/SM812 combination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Are the backup batteries included?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes, the kit includes two lithium backup batteries (4943013-6), one for each controller, to preserve memory during power loss.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047903985796,"sku":"3BSE082896R1","price":190.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/PM858K02-2.jpg?v=1767619340"},{"product_id":"abb-pm857k01-ac-800m-high-integrity-controller","title":"ABB PM857K01 AC 800M High Integrity Controller","description":"\u003ch2\u003e\u003cstrong\u003eABB PM85701 AC 800M High Integrity Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e6c80;\"\u003e3BSE088385R1 (PM85701)\u003c\/span\u003e\u003c\/strong\u003e is an ABB AC 800M High Integrity process controller. It combines standard process control with safety functions up to \u003cstrong\u003eSIL 3\u003c\/strong\u003e when paired with an SM812 safety module. This unit is designed for critical applications requiring high availability and functional safety.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e ABB \u003cstrong\u003ePM85701\u003c\/strong\u003e (Article: 3BSE088385R1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e MPC866 @ 96 MHz, 32 MB RAM (22 MB for application)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Certification:\u003c\/strong\u003e Up to SIL 3 (IEC 61508) with SM812 module; TÜV certified.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Capacity:\u003c\/strong\u003e Max 128 signals total; supports S800 I\/O High Integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e 2x RJ45 Ethernet (Control Network), 2x RS-232C serial ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e Supports CPU redundancy for high availability (switchover \u0026lt;10 ms).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC (19.2-30V), typical 5.1 W dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFeatures, Safety \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh Integrity Feature:\u003c\/strong\u003e Enabled by plug-in SM81x modules, allowing upgrade to SIL-certified schemes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Benefit:\u003c\/strong\u003e Combines safety and standard control in one controller without compromising integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Programmed with ABB 800xA Control Builder.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, cULus (Class 1, Zone 2), ISA Secure, TÜV, RoHS, marine (ABS, BV, DNV-GL).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e +5°C to +55°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 119 mm x 186 mm x 135 mm (W x H x D)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight\u003c\/strong\u003e:1.2kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What makes this a \"High Integrity\" controller?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Its architecture allows the addition of a certified safety module (SM812) to execute SIL 2\/3 safety logic alongside standard control, all within the same hardware platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is needed to achieve SIL 3 functionality?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; You must add the \u003cstrong\u003eSM812\u003c\/strong\u003e safety module and use the corresponding SIL-certified software package and configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can it be used in redundant configuration?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; Yes, two PM857 controllers can be configured for CPU redundancy to maximize system availability.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047929380996,"sku":"3BSE088385R1","price":197.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/PM857K01.jpg?v=1767618640"},{"product_id":"ci862-abb-ac-800m-trio-genius-i-o-interface-3bua000037r1","title":"CI862 ABB AC 800M TRIO Genius I\/O Interface 3BUA000037R1","description":"\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n    The \u003cspan style=\"color: #00008B; font-weight: bold;\"\u003eCI862\u003c\/span\u003e (Article Number \u003cstrong\u003e3BUA000037R1\u003c\/strong\u003e) is a dedicated communication interface module belonging to the ABB AC 800M controller family. With a net weight of only \u003cstrong\u003e0.23 kg\u003c\/strong\u003e, this lightweight yet powerful module allows the AC 800M to function as a Master on \u003cstrong\u003eTRIO\/Genius I\/O\u003c\/strong\u003e networks. It is specifically designed to provide a stable data bridge, allowing legacy I\/O systems to communicate seamlessly with modern control logic, ensuring high-speed process synchronization in various industrial sectors.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px; margin-top: 30px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n            \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #ddd; padding: 12px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProduct Model\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCI862\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #fcfcfc;\"\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eArticle Number\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e3BUA000037R1\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003e0.23 kg (Approx. 0.51 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #fcfcfc;\"\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eTRIO \/ Genius I\/O\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eOperating Mode\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eMaster\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr style=\"background-color: #fcfcfc;\"\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e5% to 95%, non-condensing\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e-40°C to +70°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px; margin-top: 30px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6;\"\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLightweight Hardware Design\u003c\/strong\u003e: At just \u003cstrong\u003e0.23 kg\u003c\/strong\u003e, the module places minimal mechanical stress on the backplane and DIN-rail mounting systems, allowing for high-density cabinet layouts.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLegacy System Integration\u003c\/strong\u003e: Enables a smooth migration path for TRIO\/Genius I\/O users to the AC 800M platform without the need for comprehensive rewiring.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eMaster Control Reliability\u003c\/strong\u003e: Efficiently manages network polling and timing, ensuring the controller CPU is dedicated to high-level logic execution rather than low-level bus management.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eStandardized Certification\u003c\/strong\u003e: Fully CE-marked and compliant with WEEE directives, ensuring the hardware meets global safety and environmental standards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2f4f4f; padding-bottom: 5px; margin-top: 30px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the shipping weight compared to the net weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: While the net weight of the CI862 is \u003cstrong\u003e0.23 kg\u003c\/strong\u003e, the total shipping weight (including protective anti-static packaging and box) is typically estimated around \u003cstrong\u003e0.45 kg to 0.5 kg\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does the weight of the module affect its vibration resistance?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: No, the lightweight design of the CI862 is a result of advanced circuit integration and is fully tested to meet standard industrial vibration and shock requirements for the AC 800M series.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is the CI862 compatible with all versions of AC 800M?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: It is compatible with the standard AC 800M controller range. However, configuration requires appropriate versions of the ABB Control Builder software that support the TRIO\/Genius protocol libraries.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047932231812,"sku":"3BUA000037R1","price":114.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3bua000037r1.jpg?v=1779108121"},{"product_id":"abb-pm858k01-compact-process-controller-33-mhz","title":"ABB PM858K01 Compact Process Controller 33 MHz","description":"\u003ch2\u003e\u003cstrong\u003eABB PM858K01 AC 800M Standard Process Controller\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e\u003cspan style=\"color: #2e6c80;\"\u003e3BSE082895R1 (PM858K01)\u003c\/span\u003e\u003c\/strong\u003e is an ABB AC 800M standard process controller. It provides reliable control for non-safety applications with essential communication and I\/O connectivity. This unit features easy DIN rail mounting and is compatible with System 800xA.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e ABB \u003cstrong\u003ePM858K01\u003c\/strong\u003e (Article: 3BSE082895R1)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCPU:\u003c\/strong\u003e MPC866 @ 33 MHz, 16 MB RAM (7.1 MB for application)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFunction:\u003c\/strong\u003e Standard process control (Not for High Integrity\/SIL applications).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e 2x RJ45 Ethernet, 2x RS-232C serial ports.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Easy slide \u0026amp; lock mechanism on DIN rail (TP830 base plate).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Support:\u003c\/strong\u003e Supports S800 I\/O via Modulebus and CEX-Bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e 24 V DC (19.2-30V), typical 5.1 W dissipation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical Data, Compatibility \u0026amp; Certifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1200 grams (approximately 2.6 lbs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 119 mm x 186 mm x 135 mm (W x H x D).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKey Feature:\u003c\/strong\u003e Unique hardware Ethernet address on the base plate for identification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e Requires System 800xA 6.0.2 or Compact Control Builder 6.0.0-1 and later.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, cULus (Class 1, Zone 2), ISA Secure, RoHS, WEEE, marine (DNV-GL).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e +5°C to +55°C.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: Can this controller be used for safety applications (SIL)?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; No. The \u003cstrong\u003ePM858K01\u003c\/strong\u003e is for standard process control only. For safety functions, you need a High Integrity controller like the PM857 with an SM81x module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What is the slide \u0026amp; lock mechanism?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; It allows for quick tool-less attachment and detachment of the controller from the DIN rail, simplifying installation and maintenance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eQ: What software is required?\u003c\/strong\u003e\u003cbr\u003eA\u0026gt; It must be configured using ABB's 800xA Control Builder or Compact Control Builder, version 6.0.0-1 or higher.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047935115396,"sku":"3BSE082895R1","price":184.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/PM858K01.jpg?v=1767619019"},{"product_id":"allen-bradley-1746-ob8-slc-500-digital-output-module","title":"Allen-Bradley 1746-OB8 SLC 500 Digital Output Module","description":"\u003ch2\u003eAllen-Bradley 1746-OB8 SLC 500 Digital Output Module\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong style=\"color: #2e86c1;\"\u003e1746-OB8\u003c\/strong\u003e is an 8-channel digital output module for SLC 500 systems.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Allen-Bradley \u003cstrong\u003e1746-OB8\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Channels:\u003c\/strong\u003e \u003cstrong style=\"color: #27ae60;\"\u003e8 digital outputs\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e 10-50 Volts DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent per Output:\u003c\/strong\u003e 1A or 0.5A selectable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTotal Current:\u003c\/strong\u003e 8A or 4A maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong style=\"color: #27ae60;\"\u003e0.3 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical \u0026amp; Safety\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Voltage:\u003c\/strong\u003e 1500V AC for 1 minute\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e -20°C to 60°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 100,000 hours\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current:\u003c\/strong\u003e 135mA at 5V\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompliance \u0026amp; Dimensions\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e CE, UL, RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 12.7 × 5.1 × 15.2 cm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection:\u003c\/strong\u003e Short circuit and overload\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003ch4\u003eHow many output channels are available?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eThe module provides \u003cstrong style=\"color: #27ae60;\"\u003e8 digital output channels\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the module weight?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIt weighs \u003cstrong style=\"color: #27ae60;\"\u003e0.3 kg\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eWhat is the operating temperature range?\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOperating range: \u003cstrong style=\"color: #27ae60;\"\u003e-20°C to 60°C\u003c\/strong\u003e.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050295591044,"sku":"1746-OB8","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1746-OB8_3.jpg?v=1769177886"},{"product_id":"1769-iq16f-allen-bradley-24v-dc-sink-source-high-speed-module","title":"1769-IQ16F Allen-Bradley 24V DC Sink Source High Speed Module","description":"\u003ch2 style=\"color: #2c3e50; border-bottom: none; padding-bottom: 6px;\"\u003eAllen-Bradley \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e1769-IQ16F\u003c\/span\u003e High Speed DC Input Module\u003c\/h2\u003e\n\n\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eAllen-Bradley \u003cspan style=\"color: #2980b9; font-weight: bold;\"\u003e1769-IQ16F\u003c\/span\u003e is a 16 point high speed DC input module for CompactLogix systems. It supports sink or source wiring configuration with 24V DC nominal voltage. Features selectable digital filters with 0 to 2ms delay settings. Designed for high speed counting and positioning applications.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; background: #f8fafc;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background: #2c3e50; color: white;\"\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 8px; border: 1px solid #ccc;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eBrand\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eModel\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1769-IQ16F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eType\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHigh Speed DC Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInputs\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e16 (8 points per group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e24V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Voltage at 30°C\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10 30V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Voltage at 60°C\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10 26.4V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWiring Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eSink or Source\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eCurrent Draw @ 5.1V\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e110 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3.55 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInrush Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInput Impedance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e3 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eON State Current\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10V DC at 2.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOFF State Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e5V DC at 1.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDigital Filter Delays\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0, 0.1, 0.5, 1, 2 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInput Delay ON to OFF\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e2 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eInput Delay OFF to ON\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e300 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eIsolation Input to Bus\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e75V (tested 1679V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003ePower Supply Distance\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e8 modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eReplacement Terminal Block\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e1769-RTBN18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWire Size Solid\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e22 14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWire Size Stranded\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e22 14 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eHumidity\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e5% to 95% non condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eDimensions H x W x D\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e118 x 35 x 87 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0.27 kg (0.60 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eShipping Weight\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e0.9 kg (2 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003eUPC\u003c\/td\u003e\n\u003ctd style=\"padding: 8px; border: 1px solid #ccc;\"\u003e10611320915676\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatibility\u003c\/h3\u003e\n\u003cp\u003eCompactLogix controllers. 1769 series I\/O expansion. Mount on DIN rail or panel. Single slot width. Supports Series A and B revisions.\u003c\/p\u003e\n\n\u003ch3\u003eInstallation\u003c\/h3\u003e\n\u003cp\u003eMount on DIN rail or panel using 6 lb in terminal screws. Use 22 14 AWG solid or stranded copper wire rated at 90°C. Requires 1769 RTBN18 replacement terminal block. Maintain proper clearance for ventilation.\u003c\/p\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cp\u003eHigh speed operation with selectable digital filters from 0 to 2ms. Sink or source wiring configuration. 75V isolation with reinforced insulation tested at 1679V DC. Status indicators and channel diagnostics. High speed counting and positioning applications.\u003c\/p\u003e\n\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the difference between 1769-IQ16F and standard 1769-IQ16?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e 1769-IQ16F offers high speed operation with selectable digital filters down to 0ms delay. Standard IQ16 has fixed slower filter settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e What is the input voltage range?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e At 30°C the range is 10V to 30V DC. At 60°C the range is 10V to 26.4V DC.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What filter settings are available?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Selectable digital filters include 0ms, 0.1ms, 0.5ms, 1ms, and 2ms for ON\/OFF and OFF\/ON transitions.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050305093764,"sku":"1769-IQ16F","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1769-IQ16F.jpg?v=1783428155"},{"product_id":"1769-of4-allen-bradley-compactlogix-4-channel-output-module","title":"1769-OF4 Allen-Bradley CompactLogix 4-Channel Output Module","description":"\u003ch2 style=\"color: #003366; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003eThe Allen-Bradley \u003cstrong\u003e1769-OF4\u003c\/strong\u003e is a high-precision analog output module designed for the CompactLogix and MicroLogix 1500 platforms. Featuring four high-density channels, the \u003cstrong\u003e1769-OF4\u003c\/strong\u003e allows controllers to send precise voltage or current signals to actuators, speed controllers, and other analog-driven industrial equipment. \u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eVersatile Signal Ranges\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eThe \u003cstrong\u003e1769-OF4\u003c\/strong\u003e provides exceptional flexibility by supporting multiple output configurations. Each channel can be independently programmed to deliver voltage ranges such as -10 to 10V, 0 to 10V, 0 to 5V, or 1 to 5V. For current-based applications, it supports standard 0 to 20 mA and 4 to 20 mA ranges, ensuring compatibility with a wide array of industrial field devices.\u003c\/p\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eBuilt-in Circuit Protection\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eTo ensure long-term operational reliability, the \u003cstrong\u003e1769-OF4\u003c\/strong\u003e is equipped with advanced protection features. It includes native support for open-circuit detection and short-circuit protection, preventing hardware damage during wiring faults or field device failures. This proactive protection architecture minimizes system downtime and simplifies troubleshooting for maintenance teams.\u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; border: 1px solid #dddddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e\u003cstrong\u003e1769-OF4\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e4 Single-Ended Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eVoltage Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e±10V, 0-10V, 0-5V, 1-5V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eCurrent Ranges\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e120 mA (5.1V) \/ 170 mA (24V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e2.86 Watts (Maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eSlot Width\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e1 Slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e0.45 kg (1.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eModule Placement:\u003c\/strong\u003e The \u003cstrong\u003e1769-OF4\u003c\/strong\u003e is a single-slot module. Ensure it is firmly seated on the DIN rail and properly engaged with the bus connectors of adjacent modules.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Considerations:\u003c\/strong\u003e Calculate the total backplane current draw; the \u003cstrong\u003e1769-OF4\u003c\/strong\u003e requires 120 mA at 5.1V and 170 mA at 24V. Verify that your system power supply can handle the aggregate load.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cable for analog output signals to minimize electromagnetic interference (EMI). Ensure the shield is grounded at one end only (typically at the controller side).\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eShort-Circuit Safety:\u003c\/strong\u003e While the \u003cstrong\u003e1769-OF4\u003c\/strong\u003e supports short-circuit protection, prolonged exposure to faults should be avoided to prevent excessive heat buildup within the enclosure.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eThe \u003cstrong\u003e1769-OF4\u003c\/strong\u003e offers a streamlined path for controlling variable speed drives and modulating valves. By integrating these four channels directly into the CompactLogix I\/O backplane, engineers benefit from lower latency compared to remote Ethernet-based analog adapters. Its support for the high-speed backplane allows for rapid updates of logic references, making the \u003cstrong\u003e1769-OF4\u003c\/strong\u003e a preferred choice for high-speed PID control loops and precision dosing applications.\u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\u003cstrong\u003eQ1: Can I mix voltage and current outputs on the same 1783-OF4 module?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, each channel on the \u003cstrong\u003e1769-OF4\u003c\/strong\u003e is individually configurable via software, allowing you to use voltage on one channel and current on another simultaneously.\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\u003cstrong\u003eQ2: Does the 1769-OF4 require an external power supply for the analog loops?\u003c\/strong\u003e\u003cbr\u003eA2: The module draws its operating power (5.1V and 24V) from the Compact I\/O backplane. However, depending on your field device requirements, external loop power may be necessary for the wiring circuit.\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\u003cstrong\u003eQ3: How does the module indicate an open-circuit fault?\u003c\/strong\u003e\u003cbr\u003eA3: The \u003cstrong\u003e1769-OF4\u003c\/strong\u003e provides diagnostic bits that can be monitored in your controller's tag database, and individual channel LEDs will indicate fault status for rapid visual inspection.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050307551364,"sku":"1769-OF4","price":199.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1769-OF4.jpg?v=1776577577"},{"product_id":"allen-bradley-1769-sm2-dsi-modbus-module","title":"Allen-Bradley 1769-SM2 DSI Modbus Module","description":"\u003ch2 style=\"color: #003366; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003eThe Allen-Bradley \u003cstrong\u003e1769-SM2\u003c\/strong\u003e is a versatile Compact I\/O communication module that enables seamless integration between CompactLogix or MicroLogix 1500 controllers and PowerFlex drives. By supporting both DSI and Modbus RTU protocols, the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e provides a cost-effective solution for distributed drive control. \u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eDual-Protocol Versatility\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eThe \u003cstrong\u003e1769-SM2\u003c\/strong\u003e excels in multi-protocol environments. It supports a fixed 19.2 kbps DSI rate for Allen-Bradley drives and adjustable Modbus RTU speeds ranging from 300 to 38.4 kbps. This flexibility allows engineers to interface with a wide range of peripheral devices and legacy systems using a single hardware footprint.\u003c\/p\u003e\n\u003ch3 style=\"color: #0055aa; margin-top: 20px;\"\u003eSystem Integration\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eDesigned for the CompactLogix platform, the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e draws power directly from the backplane (350mA @ 5V DC). Its small form factor supports DIN rail or panel mounting, making it ideal for space-constrained enclosures where efficient hardware density is critical for system performance.\u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 15px; border: 1px solid #dddddd;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f8f9fa;\"\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eAttribute\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #dddddd; padding: 12px; text-align: left; color: #003366;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003ePart Number\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e\u003cstrong\u003e1769-SM2\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eProtocols\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eDSI \u0026amp; Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eController Compatibility\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eCompactLogix, MicroLogix 1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eDrive Support\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003ePowerFlex 4-Class, PowerFlex 7-Class\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eCurrent Draw\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e350mA @ 5V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e-10°C to 50°C (14°F to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eVibration\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e5g @ 10-500Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px; font-weight: bold;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e0.28 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eDistance Limits:\u003c\/strong\u003e Maintain a maximum cable length of 10 meters when connecting the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e to PowerFlex drives to ensure signal integrity.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eNetwork Expansion:\u003c\/strong\u003e For Modbus networks, the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e supports a maximum distance of 1219 meters (4000 feet).\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003ePower Supply Distance:\u003c\/strong\u003e Do not install the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e module more than 4 slots away from the system power supply to prevent voltage drops.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 8px;\"\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation area is free from corrosive vapors and meets the vibration resistance specifications of 5g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333;\"\u003eThe \u003cstrong\u003e1769-SM2\u003c\/strong\u003e eliminates the need for complex external gateways by providing native drive communication within the CompactLogix I\/O bank. This tight integration allows for better diagnostic visibility and faster commissioning of PowerFlex drive systems. Its ability to host Modbus RTU traffic makes the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e a powerful tool for hybrid systems requiring both proprietary and open-standard communication.\u003c\/p\u003e\n\u003ch2 style=\"color: #003366; font-weight: bold; margin-top: 30px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 15px;\"\u003e\u003cstrong\u003eQ1: Can the 1769-SM2 control multiple drives simultaneously?\u003c\/strong\u003e\u003cbr\u003eA1: Yes, the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e features three channels that can independently interface with PowerFlex 4-Class or 7-Class drives depending on the configuration.\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\u003cstrong\u003eQ2: Does the 1769-SM2 require an external 24V power source?\u003c\/strong\u003e\u003cbr\u003eA2: No. The \u003cstrong\u003e1769-SM2\u003c\/strong\u003e is fully powered by the 1769 backplane via the 5V DC supply, drawing 0mA from the 24V DC bus.\u003c\/p\u003e\n\u003cp style=\"line-height: 1.6; color: #333333; margin-top: 10px;\"\u003e\u003cstrong\u003eQ3: Is the Modbus baud rate fixed like the DSI speed?\u003c\/strong\u003e\u003cbr\u003eA3: No. While DSI is fixed at 19.2 kbps, the Modbus RTU communication speed on the \u003cstrong\u003e1769-SM2\u003c\/strong\u003e is adjustable between 300 and 38,400 bps.\u003c\/p\u003e\n\u003ch3 style=\"margin-top: 30px;\"\u003eDownload Data Sheet\u003c\/h3\u003e\n\u003cp style=\"margin-top: 15px;\"\u003e\u003ca style=\"background-color: #003366; color: white; padding: 10px 20px; text-decoration: none; border-radius: 4px; display: inline-block; font-weight: bold;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/1769_CompactLogix_Controllers_User_Manual.pdf?v=1752113701\" target=\"_blank\"\u003eAccess Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050308436100,"sku":"1769-SM2","price":218.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1769-SM2-1.jpg?v=1776576657"},{"product_id":"200350-02-00-00-bently-nevada-vibration-sensor-100mv-g","title":"200350-02-00-00 Bently Nevada Vibration Sensor 100mV\/g","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a237e;\"\u003e200350-02-00-00\u003c\/strong\u003e is a high-performance seismic accelerometer engineered by Bently Nevada for demanding industrial vibration analysis. Manufactured in the USA, this sensor utilizes a shear-mode ceramic sensing element to deliver superior stability and reduced sensitivity to base strain and thermal transients. With a frequency response extending to 10 kHz, it is specifically designed to capture high-frequency mechanical faults such as gear mesh issues and early-stage bearing wear, providing the essential data required for modern predictive maintenance programs.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a237e;\"\u003e200350-02-00-00\u003c\/strong\u003e configuration is tailored for international mechanical standards. The \"02\" mounting option features a 1\/4-28 to M8 x 1.25 stainless steel adapter stud, allowing for seamless integration into machinery with metric mounting points. The \"00\" tolerance provides the industry-standard 100 mV\/g (±20%) sensitivity, while the final \"00\" indicates a standard industrial version without specific hazardous area agency approvals. The unit features a top-exit 2-pin Mil-C-5015 connector and a rugged 11\/16” hex base for secure installation in tight industrial spaces.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSensitivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e100 mV\/g ± 20% (10.2 mV\/m\/s²)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFrequency Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.5 Hz to 10,000 Hz (30 – 600,000 cpm)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eMeasurement Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e± 50 g peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.051 kg (1.8 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOperating Temp\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-54°C to +121°C (-65°F to +250°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eIP68 \/ Welded Hermetic\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eFor optimal high-frequency performance, the \u003cstrong\u003e200350-02-00-00\u003c\/strong\u003e must be installed on a flat, machined surface with a maximum torque of 2.7 to 6.8 N-m (2 to 5 ft-lb). Ensure the M8 x 1.25 mounting stud is fully seated to prevent signal resonance that can occur at the 25 kHz resonant frequency. While the housing is IP68 rated and hermetically sealed, the 2-pin Mil-C-5015 connector should be protected from direct fluid spray or chemical contaminants to maintain electrical isolation (\u0026gt;10^8 ohms). A Certificate of Origin (COO) can be provided upon request for international shipping compliance.\u003c\/p\u003e\n\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e200350-02-00-00\u003c\/strong\u003e excels in precision monitoring due to its ±1% amplitude linearity and exceptionally low transverse sensitivity (≤7%). The shear-mode sensing geometry ensures that the accelerometer remains unaffected by machine base bending or thermal expansion, which often cause errors in compression-style sensors. With a rapid settling time of 2.0 seconds and a low broadband electrical noise of 350 μg, this sensor provides clean, actionable data immediately upon power-up, even in electrically noisy industrial environments.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Can this sensor be used in wet or condensing environments?\u003cbr\u003e\nA1: Yes, the IP68 rating and welded hermetic seal allow the sensor to operate in 100% condensing humidity. However, for continuous submersion, specialized waterproof cabling is required.\u003c\/p\u003e\n\u003cp\u003eQ2: What excitation voltage is required for the 200350-02-00-00?\u003cbr\u003e\nA2: The sensor requires a constant current excitation of 2 to 20 mA at a voltage range of 18 to 28 VDC, which is standard for most Bently Nevada monitoring systems.\u003c\/p\u003e\n\u003cp\u003eQ3: What is the benefit of the Stainless Steel M8 mounting stud?\u003cbr\u003e\nA3: The stainless steel construction offers high corrosion resistance and high stiffness, ensuring the mechanical connection does not degrade in harsh industrial settings, which is vital for maintaining frequency response accuracy.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050323837060,"sku":"200350-02-00-00","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/200350-02-00-00.jpg?v=1778075196"},{"product_id":"allen-bradley-2097-v33pr5-2-0-kw-ethernet-ip-servo-drive","title":"Allen-Bradley 2097-V33PR5 | 2.0 kW Ethernet\/IP Servo Drive","description":"\u003ch2\u003e\u003cstrong\u003eAllen-Bradley Kinetix 300 Ethernet\/IP Indexing Servo Drive 2097-V33PR5\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cstrong style=\"color: #2e74b5;\"\u003e2097-V33PR5\u003c\/strong\u003e is a high-performance servo drive from the Kinetix 300 series. It delivers precise motion control via Ethernet\/IP for indexing applications. This drive supports flexible power input and integrates safety features like Safe Torque-Off for secure operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Allen-Bradley \u003cstrong style=\"color: #2e74b5;\"\u003e2097-V33PR5\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Kinetix 300 Ethernet\/IP Indexing Drive\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 80-132V AC (1-Phase), 80-264V AC (1\/3-Phase)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Frequency:\u003c\/strong\u003e 48–62 Hz\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContinuous Output:\u003c\/strong\u003e 8.0 A RMS \/ 11.3 A (0-Pk)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeak Output:\u003c\/strong\u003e 24.0 A RMS \/ 33.9 A (0-Pk)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput Power:\u003c\/strong\u003e 2.0 kW Continuous\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Power Backup:\u003c\/strong\u003e 20–26V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafe Torque-Off (STO):\u003c\/strong\u003e Yes, ISO 13849-1 PLd\/SIL2 Certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c65911;\"\u003eEtherNet\/IP Connectivity:\u003c\/strong\u003e Enables networked motion control and easy integration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced Indexing:\u003c\/strong\u003e Executes 5 indexing types, 32 indexes, with S-Curve and trapezoidal moves.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmart Motor Technology:\u003c\/strong\u003e Auto-configures with compatible MP-Series and TL-Series motors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Control:\u003c\/strong\u003e Supports PTO, analog, and Ethernet\/IP command modes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Safety:\u003c\/strong\u003e Safe Torque-Off function allows safe maintenance while powered.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePhysical \u0026amp; Environmental\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 9.37\" x 7.29\" x 3.72\" (238 x 185 x 94 mm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 4.4 lbs (2.0 kg)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e 67 Watts\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e 32° to 104°F (0° to 40°C)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClearance Requirements:\u003c\/strong\u003e 3 mm sides, 25 mm bottom\/rear for ventilation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is Safe Torque-Off (STO)?\u003c\/strong\u003e\u003cbr\u003eAn integrated safety function that cuts motor torque, allowing safe access while the drive remains powered, meeting safety standard ISO 13849-1.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan this drive run on single-phase power?\u003c\/strong\u003e\u003cbr\u003eYes, it supports single-phase input from 80-264V AC, as well as three-phase input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDoes it require special configuration software?\u003c\/strong\u003e\u003cbr\u003eIt uses Allen-Bradley's Studio 5000 or Connected Components Workbench for setup and programming.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050332094596,"sku":"2097-V33PR5","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/2097-V33PR5-2.jpg?v=1767703722"},{"product_id":"21000-16-05-00-094-03-02-probe-housing-bently-nevada","title":"21000-16-05-00-094-03-02 Probe Housing Bently Nevada","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 21000-16-05-00-094-03-02\u003c\/strong\u003e is a rugged aluminum proximity probe housing assembly designed to protect \u003cstrong\u003e3300 XL 8mm sensors\u003c\/strong\u003e in harsh industrial environments. \u003c\/p\u003e\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 21000 Housing Assembly(\u003cstrong\u003e21000-16-05-00-094-03-02\u003c\/strong\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Option (-16):\u003c\/strong\u003e 3300 XL 8mm Probe\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Option (-05):\u003c\/strong\u003e 0.5 meter (20\") cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePenetration (-094):\u003c\/strong\u003e 9.4 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFittings (-03):\u003c\/strong\u003e Includes 3\/4-14 NPT plug, reducer, and cable seal grip\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Thread:\u003c\/strong\u003e 3\/4-14 NPT (1\/2-14 NPT via included reducer)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e-40°C to +120°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eC36000 Brass \/ Aluminum options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eTotal Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e1.1 kg (approx.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eBently Nevada 3300 XL Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003eThis assembly allows for \u003cstrong\u003eeasy external access\u003c\/strong\u003e to proximity probes without machine disassembly. Use the included cable seal grip to ensure environmental protection for cable diameters ranging from 1\/8\" to 3\/8\".\u003c\/p\u003e\n\u003ch2\u003eKey Advantages\u003c\/h2\u003e\n\u003cp\u003eEngineered for the Oil \u0026amp; Gas and Power Generation sectors, the 21000 series offers superior protection against mechanical damage and environmental contaminants, ensuring continuous machinery protection and data accuracy.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the benefit of the -03 fitting option?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: It provides a complete seal kit including an NPT plug and cable grip, allowing for immediate installation in varied NPT systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is this housing explosion-proof?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, when installed according to Bently Nevada certifications, it meets industrial safety standards for hazardous areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it include the probe?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: This assembly is designed to house the probe. Please verify if the internal probe is included in your specific kit order.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDownload Datasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/21000-24701-Datasheet.pdf\" target=\"_blank\"\u003eAccess PDF Specifications\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050333208708,"sku":"21000-16-05-00-094-03-02","price":339.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-16-05-00-094-03-02.jpg?v=1775891360"},{"product_id":"bently-nevada-21000-16-05-15-037-01-02-explosion-proof-housing","title":"Bently Nevada 21000-16-05-15-037-01-02 Explosion-Proof Housing","description":"\u003ch2 style=\"color: #2f4f4f;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong\u003eBently Nevada 21000-16-05-15-037-01-02\u003c\/strong\u003e is a ruggedized, explosion-proof proximity probe housing assembly designed for the most volatile industrial environments. This 21000-series model integrates a high-precision \u003cstrong\u003e3300 XL 8mm probe\u003c\/strong\u003e into a protective enclosure, making it the industry standard for chemical plants, refineries, and mining operations. Weighing approximately \u003cstrong\u003e1.1kg\u003c\/strong\u003e (without fittings), this assembly provides a secure, sealed interface for vibration and position monitoring in Class I, II, and III hazardous zones.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\n  This configuration is optimized for deep-reach penetration and specialized hazardous-area mounting:\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull Model:\u003c\/strong\u003e 21000-16-05-15-037-01-02\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Type (16):\u003c\/strong\u003e Includes the reliable 3300 XL 8mm Proximity Probe.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Cable Length (05):\u003c\/strong\u003e Compact 0.5 meter (20 inches) cable for local junction connectivity.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandoff Adapter (15):\u003c\/strong\u003e Features a 1.5-inch adapter for precise probe gapping.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Penetration (037):\u003c\/strong\u003e 307mm (12.1 inches) depth, ideal for large bearing housings.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFittings Option (01):\u003c\/strong\u003e Includes explosion-proof fittings (3\/4-14 NPT thread).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Thread (02):\u003c\/strong\u003e Standard 3\/4-14 NPT industrial mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eSpecification Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eHousing Material\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAluminum and Stainless Steel construction\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Temp Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-50°C to +80°C (-58°F to +176°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCSA Type 4 \/ Explosion-Proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCompliance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eAPI 670 Standard compliant\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eInternal Probe\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e3300 XL 8 mm (75 Ω coaxial)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\n  Safety is paramount when installing the \u003cstrong\u003e21000-16-05-15-037-01-02\u003c\/strong\u003e. For installations where probe penetration exceeds 12 inches (305mm), a sleeve support is critically recommended to prevent mechanical deflection or vibration-induced fatigue of the probe case. The assembly features a 3\/4-14 NPT standard thread for mounting into the machine housing. Ensure all explosion-proof fittings are tightened to local electrical code specifications to maintain the CSA Type 4 rating and prevent moisture or gas ingress.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003e\n  The primary advantage of the Bently Nevada 21000 series is its \u003cstrong\u003eDual-Layer Protection\u003c\/strong\u003e. Not only does the external aluminum\/stainless steel housing provide a fire-safe barrier, but the internal 3300 XL probe offers the gold-standard in eddy current measurement accuracy. The assembly includes a flag label for easy identification of probe details in the field, and the compact 0.5m cable minimizes signal noise in tight spaces. Its wide temperature rating (-50°C to +80°C) ensures reliable operation in both sub-zero arctic mining and high-heat chemical processing environments.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cstrong\u003eQ1: Is the internal probe replaceable?\u003c\/strong\u003e\u003cbr\u003e\n  A1: Yes, the internal 3300 XL 8mm probe can be replaced or serviced without necessarily discarding the entire explosion-proof housing, provided the integrity of the enclosure remains intact.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cstrong\u003eQ2: What does \"307mm penetration\" refer to?\u003c\/strong\u003e\u003cbr\u003e\n  A2: This is the length from the mounting face of the housing to the tip of the probe, indicating how far the probe extends into the machine to reach the target shaft.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cstrong\u003eQ3: Does this housing meet offshore requirements?\u003c\/strong\u003e\u003cbr\u003e\n  A3: While it is CSA and Explosion-Proof rated, please verify specific maritime certifications (like ABS or DNV) if using on offshore platforms, though it is frequently used in similar onshore hazardous zones.\n\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050333470852,"sku":"21000-16-05-15-037-01-02","price":192.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-16-05-15-037-01-02.jpg?v=1776863728"},{"product_id":"bently-nevada-21000-16-10-00-072-03-02-housing","title":"Bently Nevada 21000-16-10-00-072-03-02 Housing","description":"\u003ch2\u003eBently Nevada 21000-16-10-00-072-03-02 Proximity Probe Housing Assembly\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada | \u003cstrong\u003eCondition:\u003c\/strong\u003e New \u0026amp; Original | \u003cstrong\u003eWarranty:\u003c\/strong\u003e 12 Months\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Diameter:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e8 mm\u003c\/span\u003e (3300 XL Series)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e1.0 m \/ 39 in\u003c\/span\u003e (Max Extended Length: 32.9 in \/ 83.5 cm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePenetration Depth:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e7.2 inches\u003c\/span\u003e (Optimized for industrial clearance requirements)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e1.1 kg \/ 2.4 lb\u003c\/span\u003e (Lightweight aluminum-stainless steel construction)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eThread Standard:\u003c\/strong\u003e \u003cspan style=\"color: #e74c3c;\"\u003e3\/4-14 NPT\u003c\/span\u003e (Dual sealing with NPT plug and reducer)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003ePremium Features\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Durability:\u003c\/strong\u003e Aluminum body with \u003cspan style=\"color: #e74c3c;\"\u003e304 stainless steel sleeve\u003c\/span\u003e (Corrosion resistance up to 480 hours salt spray test)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHazardous Area Certification:\u003c\/strong\u003e CSA Type 4 explosion-proof rating (Compliant with API 670 Standard Rev. 5)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSealing System:\u003c\/strong\u003e Triple-layer protection with \u003cspan style=\"color: #e74c3c;\"\u003e3 cable grommets\u003c\/span\u003e (1\/8\" to 3\/8\" diameter range) + IP66 environmental protection\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cstrong\u003eContact Technical Team:\u003c\/strong\u003e \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #2a5db0;\"\u003esale@etowonauto.com\u003c\/a\u003e for bulk pricing\u003c\/p\u003e\n\n\u003ch3\u003eProduct Documentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/21000-24701-Datasheet.pdf?v=1740714042\" target=\"_blank\" style=\"color: #2a5db0; font-weight: bold;\"\u003eDownload Detailed Product Specifications (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050334224516,"sku":"21000-16-10-00-072-03-02","price":266.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-16-10-00-072-03-02-1.jpg?v=1774076276"},{"product_id":"21000-16-10-15-144-03-02-bently-nevada-21000-aluminum-housing","title":"21000-16-10-15-144-03-02 Bently Nevada 21000 Aluminum Housing","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong\u003eBently Nevada 21000-16-10-15-144-03-02\u003c\/strong\u003e is an ultra-long reach proximity probe housing assembly designed for large-scale industrial machinery. With a \u003cstrong\u003e14.4-inch penetration depth\u003c\/strong\u003e, this aluminum housing provides a secure, explosion-proof environment for 3300 XL 8mm sensors in deep-mount applications.\n\u003c\/p\u003e\n\u003cp\u003e\n  This model is specifically engineered for critical vibration monitoring on \u003cstrong\u003ehydroelectric turbines and large petrochemical pumps\u003c\/strong\u003e. Fully compliant with \u003cstrong\u003eAPI 670\u003c\/strong\u003e, it allows for external probe gapping and replacement without compromising machine integrity.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e 21000 (Aluminum Body \/ 304 Stainless Steel Sleeve)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Option (-16):\u003c\/strong\u003e 3300 XL 8mm Probe\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length (-10):\u003c\/strong\u003e 1.0 meter (39 in)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eStandoff Adapter (-15):\u003c\/strong\u003e 1.5 inch (38 mm)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProbe Penetration (-144):\u003c\/strong\u003e 14.4 inches (Ultra-Long Reach)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFittings (-03):\u003c\/strong\u003e Includes NPT plug, reducer, and cable seal kit\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting Thread (-02):\u003c\/strong\u003e 3\/4-14 NPT\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #ccc;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ccc; padding: 10px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eHazardous Area Rating\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eCSA Certified Explosion-Proof\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003eAPI 670 | FCC Part 15 | RoHS\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eLinear Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e0–10 mm (0–390 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eAdjustment Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e±13 mm (±0.5 in)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ccc; padding: 10px;\"\u003e1.1 kg (2.4 lb) typical\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Best Practices\u003c\/h2\u003e\n\u003cp\u003e\n  Due to the \u003cstrong\u003e14.4\" sleeve length\u003c\/strong\u003e, it is highly recommended to provide additional sleeve support to prevent resonance during operation. Ensure the 3\/4-14 NPT port is clean and free of debris. Use the included 3-size grommet kit to secure field wiring ranging from 1\/8\" to 3\/8\" diameter.\n\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003e\n  The 21000 series \"Reverse Mount\" design allows for probe maintenance from the exterior of the machine housing. This is vital for high-availability systems where stopping the machine for a sensor adjustment is not an option. The combination of lightweight aluminum and durable 304 SST ensures corrosion resistance in harsh environments.\n\u003c\/p\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is this housing rated for hazardous zones?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, it is CSA certified for explosion-proof applications in Class 1 Div 1\/2 environments.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I adjust the probe depth after installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, the assembly provides an adjustment range of approximately ±0.5 inches to fine-tune the gap setting.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Does the package include a reducer?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the \u003cstrong\u003e-03 option\u003c\/strong\u003e includes a 3\/4-14 to 1\/2-14 NPT reducer for standard conduit connectivity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eDownload Datasheet:\u003c\/strong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/21000-24701-Datasheet.pdf\" target=\"_blank\"\u003eAccess PDF Specifications\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050335338628,"sku":"21000-16-10-15-144-03-02","price":366.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-16-10-15-144-03-02.jpg?v=1775893783"},{"product_id":"21000-28-05-00-065-00-02-bently-nevada-probe-housing-assembly","title":"21000-28-05-00-065-00-02 Bently Nevada Probe Housing Assembly","description":"\u003ch2\u003e21000-28-05-00-065-00-02 Proximity Probe Housing Assembly\u003c\/h2\u003e\n\u003ch3\u003eCore Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial:\u003c\/strong\u003e Aluminum body with 304 stainless steel sleeve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.1 kg (2.4 lb) typical, without fittings\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Certification:\u003c\/strong\u003e CSA Type 4 enclosure, API 670 Standard compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Length:\u003c\/strong\u003e 0.5m to 3.0m options\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVisible Probe Marking Area:\u003c\/strong\u003e 4.0 to 21.1 inches\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eConfiguration Details\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e28:\u003c\/strong\u003e 3300 XL 8mm probe with hazardous area approval\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e05:\u003c\/strong\u003e 0.5m (20 inch) cable\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e065:\u003c\/strong\u003e 6.5 inch probe penetration\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e02:\u003c\/strong\u003e 3\/4-14 NPT mounting thread\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCable Length vs Visible Marking\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e12 inch cable:\u003c\/strong\u003e Visible marking Not Visible, Max Dimension 5.0 inch (12.7 cm)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e36 inch cable:\u003c\/strong\u003e Visible marking 21.1 inch (53.6 cm), Max Dimension 27.3 inch (69.3 cm)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eDome cover with threaded conduit ports\u003c\/li\u003e\n\u003cli\u003eProbe sleeve (6.5 inch standard penetration)\u003c\/li\u003e\n\u003cli\u003e3\/4-14 NPT mounting thread adapter\u003c\/li\u003e\n\u003cli\u003eFactory-sealed with 12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCertifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eExplosion-proof rated for Class I Div 1 hazardous areas\u003c\/li\u003e\n\u003cli\u003eCSA\/NRTL certified (File E115809)\u003c\/li\u003e\n\u003cli\u003eAPI 670 5th Edition compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eQuality Assurance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eNew original unit in anti-static sealed packaging with protective caps\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eContact\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEmail: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050336059524,"sku":"21000-28-05-00-065-00-02","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/21000-28-05-00-065-00-02.jpg?v=1775476665"},{"product_id":"allen-bradley-22d-b012h204-category-3-ac-drive","title":"Allen-Bradley 22D-B012H204 Category 3 AC Drive","description":"\u003ch2 style=\"color:#1a1a1a;\"\u003eAllen-Bradley 22D-B012H204 PowerFlex 40P AC Drive\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom:20px;\"\u003e\u003cstrong style=\"color:#0066b3;\"\u003eAllen-Bradley 22D-B012H204\u003c\/strong\u003e is a PowerFlex 40P series AC drive delivering 2.2 kW (3 HP) with 12A output. Features sensorless vector, V\/Hz, and PWM control with Category 3 safe-off for safety applications.\u003c\/p\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eKey Specifications\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCatalog No.\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e22D-B012H204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003ePower\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e2.2 kW (3 HP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e12A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e240V AC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eControl Methods\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eSensorless Vector, V\/Hz, PWM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eSafe-Off\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCategory 3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCommunication\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eRS-485 (DSI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCertifications\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eCE, UL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e1.8 kg (4.0 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eEnvironmental Ratings\u003c\/h3\u003e\n\u003ctable style=\"width:100%; border-collapse:collapse; margin-bottom:20px; font-size:14px;\"\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #ddd; padding:8px; text-align:left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temp (IP20)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background:#f0f0f0;\"\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eOperating Temp (IP30)\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003e-10°C to +40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eEnclosure Options\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #ddd; padding:8px;\"\u003eIP20, IP30, IP66, Plate Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFeatures\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eCategory 3 safe-off for safety applications\u003c\/li\u003e\n\u003cli\u003eSensorless vector, V\/Hz, and PWM control\u003c\/li\u003e\n\u003cli\u003eIntegrated RS-485 port for programming\u003c\/li\u003e\n\u003cli\u003eRemovable MOV and relay pre-charge\u003c\/li\u003e\n\u003cli\u003eIntegrated brake resistor\u003c\/li\u003e\n\u003cli\u003eConfigurable PWM frequency\u003c\/li\u003e\n\u003cli\u003eZero Stacking mounting option for minimal spacing\u003c\/li\u003e\n\u003cli\u003eExternal filters available for EMC compliance (EN55011 Class A\/B)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eSoftware \u0026amp; Configuration\u003c\/h3\u003e\n\u003cul style=\"margin-bottom:20px;\"\u003e\n\u003cli\u003eIntegrated display and reset button\u003c\/li\u003e\n\u003cli\u003ePocket DriveExplorer (Windows Mobile)\u003c\/li\u003e\n\u003cli\u003eDriveTools SP software\u003c\/li\u003e\n\u003cli\u003eDriveExplorer software\u003c\/li\u003e\n\u003cli\u003eDSI connection for PC-based configuration\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color:#0066b3; margin-top:20px;\"\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the power rating?\u003c\/strong\u003e\u003cbr\u003eA1: 2.2 kW (3 HP) with 12A output current.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What safety features does this drive include?\u003c\/strong\u003e\u003cbr\u003eA2: Category 3 safe-off for safety-critical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What control methods are supported?\u003c\/strong\u003e\u003cbr\u003eA3: Sensorless vector, V\/Hz, and sinusoidal PWM.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050348445828,"sku":"22D-B012H204","price":164.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22D-B012H204-1.jpg?v=1782911700"},{"product_id":"330851-02-000-080-10-00-00-vibration-probe-bently-nevada","title":"330851-02-000-080-10-00-00 Vibration Probe Bently Nevada","description":"\u003ch2\u003eBently Nevada 330851-02-000-080-10-00-00 Proximity Probe\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330851-02-000-080-10-00-00\u003c\/strong\u003e is a 3300 XL 25 mm proximity probe. It features an 80mm case with 25bar steam pressure rating. This sensor delivers reliable monitoring for turbines, compressors, and marine thrust bearings.\u003c\/p\u003e\n\u003ch3\u003eModel Breakdown\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e330851-02:\u003c\/strong\u003e M30 x 2 thread\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e000:\u003c\/strong\u003e 0 inch unthreaded length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e080:\u003c\/strong\u003e 80 mm case length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e10:\u003c\/strong\u003e 1.0 meter cable length\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e No cable armor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e00:\u003c\/strong\u003e No agency approval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eExtended Pressure Resistance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e25bar steam pressure endurance, 3 times standard probes\u003c\/li\u003e\n\u003cli\u003e80mm case withstands 15G vibration at 60Hz\u003c\/li\u003e\n\u003cli\u003e0.02mm thermal stability from -35°C to +200°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMaterial Performance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAISI 304 SST with 9.8μm Ra surface finish\u003c\/li\u003e\n\u003cli\u003ePEEK tip maintains less than 0.5% dimensional change at 250°C\u003c\/li\u003e\n\u003cli\u003eFluidLoc® cable survives 500+ bend cycles at -50°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Documentation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3300_XL_Proximity_Transducer_System.pdf?v=1741578115\" target=\"_blank\"\u003eDownload Full Product Specifications PDF\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050371416196,"sku":"330851-02-000-080-10-00-00","price":326.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330851-02-000-080-10-00-00.jpg?v=1774785515"},{"product_id":"330505-01-02-02-bently-nevada-low-frequency-velocity-sensor","title":"330505-01-02-02 Bently Nevada Low Frequency Velocity Sensor","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a237e;\"\u003e330505-01-02-02\u003c\/strong\u003e is a high-performance low-frequency velocity sensor engineered by Bently Nevada for monitoring machinery with slow rotational speeds. Unlike standard sensors, this transducer is specifically optimized for applications like hydroelectric turbines or large fans, where detecting vibrations at frequencies as low as 0.5 Hz is critical for safety. By utilizing advanced seismic sensing technology, it provides high-resolution data on structural vibration and casing velocity, allowing maintenance teams to identify mechanical imbalances or hydraulic instabilities before they lead to costly downtime.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #1a237e;\"\u003e330505-01-02-02\u003c\/strong\u003e features a precise mechanical build tailored for specific mounting requirements. The suffix \"-01\" indicates a 0° vertical mounting orientation, ensuring maximum sensitivity along the primary axis of vibration. This model is equipped with a 3\/8-24 UNF-2B internal thread and includes an M8 x 1 mounting adapter (Option -02), providing versatile installation options for various bearing housings. Housed in 300-series stainless steel and featuring a 2-pin Mil-C-5015 hermetic connector, the hardware is built to maintain signal integrity over long cable runs when integrated with Bently Nevada 3500 series monitors.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 20px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eSensitivity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e20 mV\/mm\/s (508 mV\/in\/s) ±10%\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFrequency Response\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.5 Hz to 1000 Hz (±3.0 dB)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eVelocity Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e102 mm\/s (4 in\/s) peak\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eWeight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u0026lt; 375 grams (13.2 oz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOperating Temp\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e-40°C to +100°C\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCase Material\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e300 Series Stainless Steel\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 id=\"installation-guide\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eTo ensure accurate data, the \u003cstrong\u003e330505-01-02-02\u003c\/strong\u003e must be mounted rigidly to the machine surface using the specified torque of 46 kg·cm. The base-to-target contact must be clean and flat to avoid high-frequency damping. Given its sensitivity to low-frequency movement, avoid routing the sensor cable near high-current power lines to prevent 50\/60 Hz electrical noise. For vertical applications, ensure the sensor is oriented within ±10° of the vertical axis as specified by the -01 mounting angle option.\u003c\/p\u003e\n\n\u003ch2 id=\"engineering-advantages\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThis sensor stands out for its superior amplitude linearity (±3%) and its ability to operate in 100% non-submerged humidity. Its hermetically sealed design protects internal piezo-electronics from moisture and contaminants common in hydro-power facilities. By providing a clean signal over long distances without degradation, the \u003cstrong\u003e330505-01-02-02\u003c\/strong\u003e enables centralized monitoring of remote assets, significantly improving the efficiency of plant-wide predictive maintenance programs.\u003c\/p\u003e\n\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003eQ1: Why use a velocity sensor instead of an accelerometer for low speeds?\u003cbr\u003e\nA1: Low-speed machinery produces very low acceleration levels but measurable velocity. This sensor is specifically tuned to provide a clearer signal in those low-frequency ranges (0.5–10 Hz).\u003c\/p\u003e\n\u003cp\u003eQ2: What is the significance of the Output Bias Voltage?\u003cbr\u003e\nA2: The -12 VDC bias voltage is used by the monitor to verify the OK status of the sensor. If the bias drifts significantly, it indicates a cable fault or sensor failure.\u003c\/p\u003e\n\u003cp\u003eQ3: Can this sensor be mounted horizontally?\u003cbr\u003e\nA3: The -01 option is calibrated for vertical mounting (0°). Mounting it horizontally may affect its sensitivity; for horizontal applications, a 90° calibrated model should be selected.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050413293700,"sku":"330505-01-02-02","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330505-01-02-02-1.jpg?v=1778071053"},{"product_id":"bently-nevada-330850-90-05-3300-xl-proximitor","title":"Bently Nevada 330850-90-05 | 3300 XL Proximitor","description":"\u003ch2\u003eBently Nevada 330850-90-05 3300 XL 25 mm Proximitor Sensor\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 330850-90-05\u003c\/strong\u003e is a 3300 XL 25 mm Proximitor Sensor. Features 9.0 meter system length with panel mount configuration. Multiple agency approvals included. Made in U.S.A.\u003c\/p\u003e\n\n\u003ch2\u003eKey specifications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e 3300 XL 25 mm Proximitor Sensor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePart number:\u003c\/strong\u003e 330850-90-05\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting option:\u003c\/strong\u003e Panel mount\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSystem length:\u003c\/strong\u003e 9.0 meters (29.5 feet)\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSensor type:\u003c\/strong\u003e 25 mm Proximitor Sensor\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertifications:\u003c\/strong\u003e Multiple agency approvals\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e United States of America\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 255 g (9 oz)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eIncludes\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003e330850-90-05\u003c\/strong\u003e Proximitor sensor\u003c\/li\u003e\n  \u003cli\u003eFactory packaging\u003c\/li\u003e\n  \u003cli\u003e12-month warranty\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003eFedEx, UPS, DHL\u003c\/li\u003e\n  \u003cli\u003eTracking provided\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the system length?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e9.0 meters (29.5 feet) with panel mount.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhat certifications are included?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMultiple agency approvals for global compliance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eWhere is it manufactured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUnited States of America.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050420994180,"sku":"330850-90-05","price":215.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330850-90-05.jpg?v=1774162015"},{"product_id":"3500-15-05-05-00-bently-nevada-power-supply-65w-85-264v","title":"3500\/15-05-05-00 Bently Nevada Power Supply 65W 85-264V","description":"\u003ch2\u003e3500-15-05-05-00 Bently Nevada Power Supply – 65W 85-264VAC\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color:#0066cc;\"\u003eBently Nevada 3500-15-05-05-00\u003c\/strong\u003e is a universal AC power supply module for the 3500 Monitoring System. Accepts 85 to 264 VAC input and delivers 65 Watts output power.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Information\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eBently Nevada\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Number\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e3500-15-05-05-00\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePower Supply (106M1079-01 + 106M1081-01)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eU.S.A.\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eNew and Original\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e12 Months\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eCertificate\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCertificate of Origin (COO) Available\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e85-264 VAC RMS (Universal)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eInput Frequency\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e47-63 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e65 Watts\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eEfficiency\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u0026gt;85%\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e-40°C to 85°C (-40°F to 185°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e25.15 x 5.08 x 12.07 cm\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e1.39 kg\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eSafety Standards\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eUL \/ CSA \/ TUV Certified\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eCompatible Systems\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eBently Nevada 3500 Monitoring System\u003c\/li\u003e\n  \u003cli\u003e3500-15 Rack Interfaces\u003c\/li\u003e\n  \u003cli\u003e3500-22M Transient Data Interface\u003c\/li\u003e\n  \u003cli\u003e3500-25 Keyphasor Module\u003c\/li\u003e\n  \u003cli\u003e3500-32 4-Channel Relay\u003c\/li\u003e\n  \u003cli\u003e3500-40M Analog Monitor\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"6\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eIndustry\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePower Generation\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eTurbine Control System Power\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eOil and Gas\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCompressor Monitoring Systems\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eMarine\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003ePropulsion Monitoring Backup Power\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eManufacturing\u003c\/td\u003e\n    \u003ctd style=\"border:1px solid #ddd;\"\u003eCritical Machine Protection Systems\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003ePackage Contents\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003e3500-15 Power Supply Module\u003c\/li\u003e\n  \u003cli\u003eMounting Hardware\u003c\/li\u003e\n  \u003cli\u003eInstallation Guide\u003c\/li\u003e\n  \u003cli\u003eQuality Assurance Documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFeatures\u003c\/h3\u003e\n\u003cul\u003e\n  \u003cli\u003eUniversal AC input 85-264 VAC\u003c\/li\u003e\n  \u003cli\u003e65 Watts output power with \u0026gt;85% efficiency\u003c\/li\u003e\n  \u003cli\u003eUL, CSA, and TUV safety certified\u003c\/li\u003e\n  \u003cli\u003eDesigned for Bently Nevada 3500 Monitoring System\u003c\/li\u003e\n  \u003cli\u003eWide operating temperature range\u003c\/li\u003e\n  \u003cli\u003eCertificate of Origin available\u003c\/li\u003e\n  \u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the correct mounting orientation?\u003c\/strong\u003e\u003cbr\u003e\nA1: Install in the leftmost rack slot. Fully seat and secure with two retaining screws at 0.56 N·m (5 in·lb).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How to wire AC input?\u003c\/strong\u003e\u003cbr\u003e\nA2: Use 14-16 AWG 90°C wire. Connect L to terminal 1, N to terminal 2, Ground to terminal 3. Torque to 0.56 N·m. Use 6A circuit breaker.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Green LED off, amber on. What to check?\u003c\/strong\u003e\u003cbr\u003e\nA3: Check AC voltage at terminals. If present but green off, internal fuse is blown. Amber indicates over-temp or over-current. Verify rack ventilation and ambient below 60°C.\u003c\/p\u003e\n\n\u003ch3\u003eProduct Documentation\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\" style=\"color:#0066cc; font-weight:bold;\"\u003eDownload Detailed Product Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050450813060,"sku":"3500\/15-05-00-05","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-00-05.jpg?v=1783342954"},{"product_id":"bently-nevada-3500-61-01-00-temperature-monitor-recorder-output","title":"Bently Nevada 3500\/61-01-00 Temperature Monitor Recorder Output","description":"\u003ch2\u003eBently Nevada 3500\/61-01-00 Temperature Monitor\u003c\/h2\u003e\n\u003cp\u003eBently Nevada \u003cstrong\u003e3500\/61-01-00\u003c\/strong\u003e provides temperature monitoring with recorder outputs. This 3500 series module accepts 1 to 6 RTD or thermocouple transducer signals. \u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c0392b;\"\u003e1 to 6 channel RTD\/TC input\u003c\/span\u003e for flexible temperature monitoring configurations\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #27ae60;\"\u003e4-20mA recorder outputs\u003c\/span\u003e proportional to monitor full-scale values\u003c\/li\u003e\n\u003cli\u003eSupports Type E, J, K, T thermocouples and platinum, nickel, copper RTDs\u003c\/li\u003e\n\u003cli\u003eUser-configurable Alert and Danger setpoints from 0-100% of full-scale\u003c\/li\u003e\n\u003cli\u003eProgrammable alarm delays: 1-60 seconds for Alert, 0.5-60 seconds for Danger\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower consumption:\u003c\/strong\u003e 9 watts nominal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.91 kg (2.0 lb)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Bently Nevada\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003e3500\/61-01-00\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct type:\u003c\/strong\u003e Temperature Monitor with Recorder Outputs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O module type:\u003c\/strong\u003e RTD\/TC Non-isolated I\/O Module Internal Terminations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput impedance:\u003c\/strong\u003e 10 MΩ per lead\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRecorder output:\u003c\/strong\u003e 4-20 mA, 0-600 Ω load, 0-12 Vdc compliance\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResolution:\u003c\/strong\u003e 0.3662 µA per bit, ±0.15% error at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRTD current source:\u003c\/strong\u003e 925 ±15 µA at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction accuracy:\u003c\/strong\u003e ±1°C at 25°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlarm accuracy:\u003c\/strong\u003e ±0.13% of desired value\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating temperature:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage temperature:\u003c\/strong\u003e -40°C to +85°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor dimensions:\u003c\/strong\u003e 241.3 × 24.4 × 241.8 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMonitor weight:\u003c\/strong\u003e 0.91 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O module weight:\u003c\/strong\u003e 0.45 kg\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack space:\u003c\/strong\u003e 1 full-height front slot, 1 full-height rear slot\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCountry of origin:\u003c\/strong\u003e Made in U.S.A.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is 3500\/61-01-00?\u003c\/strong\u003e\u003cbr\u003eBently Nevada temperature monitor with recorder outputs. Accepts 1-6 RTD\/TC inputs, 9W power, 0.91kg. Made in U.S.A.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensor types does it support?\u003c\/strong\u003e\u003cbr\u003eSupports Type E, J, K, T thermocouples and platinum, nickel, copper RTDs. Resolution 1°C or 1°F.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat are the recorder output specifications?\u003c\/strong\u003e\u003cbr\u003e4-20 mA outputs proportional to full-scale. Load range 0-600 Ω with 0-12 Vdc compliance. Short circuits do not affect monitor operation.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050462347396,"sku":"3500\/61-01-00","price":511.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_61-01-00.jpg?v=1774011583"},{"product_id":"bently-nevada-3500-15-127610-01-power-supply-module","title":"Bently Nevada 3500\/15 | 127610-01 Power Supply Module","description":"\u003ch2\u003e\u003cstrong\u003eBently Nevada 3500\/15 Power Supply Module 127610-01\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eAuthor: Etowon Auto\u003c\/p\u003e\n\u003cp\u003eThe \u003cstrong\u003eBently Nevada 3500\/15\u003c\/strong\u003e provides reliable power for monitoring systems. This 127610-01 module ensures stable operation in industrial environments. It features universal AC input and redundant design capabilities.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand \u0026amp; Model:\u003c\/strong\u003e Bently Nevada \u003cstrong style=\"color: #d32f2f;\"\u003e3500\/15\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePart Number:\u003c\/strong\u003e \u003cstrong style=\"color: #d32f2f;\"\u003e127610-01\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage:\u003c\/strong\u003e 85-264 VAC RMS range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal Voltage:\u003c\/strong\u003e 110-220 VAC operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e 47-63 Hz input range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 2.8 A RMS maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEfficiency:\u003c\/strong\u003e 90% typical at full load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMTBF:\u003c\/strong\u003e 100,000 hours reliability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temp:\u003c\/strong\u003e -30°C to +65°C\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e 1.39 kg (3.06 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDimensions:\u003c\/strong\u003e 120.7 x 50.8 x 251.5 mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eWide 85-264VAC universal input range\u003c\/li\u003e\n\u003cli\u003eDual unit redundant power supply option\u003c\/li\u003e\n\u003cli\u003eHigh 90% energy efficiency rating\u003c\/li\u003e\n\u003cli\u003e100,000 hours MTBF for reliability\u003c\/li\u003e\n\u003cli\u003eNatural convection cooling system\u003c\/li\u003e\n\u003cli\u003eSupply OK LED status indicator\u003c\/li\u003e\n\u003cli\u003e1.39 kg lightweight rack design\u003c\/li\u003e\n\u003cli\u003eIndustrial temperature operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003ePackage Contents\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cstrong\u003eBently Nevada 127610-01\u003c\/strong\u003e module\u003c\/li\u003e\n\u003cli\u003eRack mounting hardware\u003c\/li\u003e\n\u003cli\u003eInstallation documentation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eShipping Information\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eFedEx, UPS, DHL shipping available\u003c\/li\u003e\n\u003cli\u003e2-5 business day processing\u003c\/li\u003e\n\u003cli\u003eInternational shipping options\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMount in 3500 series rack slot\u003c\/li\u003e\n\u003cli\u003eConnect 85-264VAC power input\u003c\/li\u003e\n\u003cli\u003eVerify proper grounding connection\u003c\/li\u003e\n\u003cli\u003eCheck Supply OK LED illumination\u003c\/li\u003e\n\u003cli\u003eConfigure redundant pair if needed\u003c\/li\u003e\n\u003cli\u003eTest system power-up sequence\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEN 61000-6-2 industrial immunity\u003c\/li\u003e\n\u003cli\u003eEN 61000-6-4 emissions standard\u003c\/li\u003e\n\u003cli\u003eEN 61010-1 electrical safety\u003c\/li\u003e\n\u003cli\u003eCE compliance certification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What systems use this power supply?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Bently Nevada 3500 monitoring and protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it handle voltage fluctuations?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes, 85-264VAC range handles most fluctuations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the weight?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e 1.39 kg (3.06 pounds).\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003eContact \u0026amp; Resources\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eEmail: sale@etowonauto.com\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\"\u003eDownload Detailed Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050722427012,"sku":"127610-01","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/127610-01.jpg?v=1769835667"},{"product_id":"allen-bradley-1606-xl120dr-24v-dc-10a-din-rail-power-supply","title":"Allen-Bradley 1606-XL120DR 24V DC 10A DIN Rail Power Supply","description":"\u003ch2 style=\"color: #2c3e50;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe Allen-Bradley \u003cspan style=\"color: #003366;\"\u003e\u003cstrong\u003e1606-XL120DR\u003c\/strong\u003e\u003c\/span\u003e is a high-performance Switched Mode Power Supply (SMPS) engineered for the demanding requirements of modern industrial automation. Part of the reliable 1606-XL Series, this 240W unit provides a regulated 10A output, ensuring stable power delivery to sensitive control components. With a lightweight and robust design weighing approximately \u003cstrong\u003e0.73 kg\u003c\/strong\u003e, the \u003cstrong\u003e1606-XL120DR\u003c\/strong\u003e excels in providing high energy density while maintaining an exceptionally cool operational environment through minimized power loss.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThis power supply is defined by its superior efficiency and intelligent feedback mechanisms. The \u003cstrong\u003e1606-XL120DR\u003c\/strong\u003e features an integrated DC-OK status signal, allowing control systems to monitor power health in real-time and react proactively to voltage drops. Its hardware architecture is optimized for 200-240V AC input ranges, utilizing advanced switching technology to reduce heat generation. Furthermore, the inclusion of pluggable terminals significantly streamlines the installation process and reduces downtime during routine maintenance or system upgrades in crowded electrical cabinets.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f8f9fa;\"\u003e\n      \u003cth style=\"border: 1px solid #dee2e6; padding: 12px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dee2e6; padding: 12px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e1606-XL120DR\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eInput Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e200-240V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eOutput Power\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e240W\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eOutput Current\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e10A\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e0.73 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eTerminals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003ePluggable Connectors\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003e\u003cstrong\u003eStatus Signal\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dee2e6; padding: 12px;\"\u003eDC-OK Relay Contact\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003cp\u003eTo maximize the service life of the 1606-XL120DR, maintain adequate clearance around the unit's ventilation slots to facilitate natural convection cooling. The pluggable terminal blocks should be wired with appropriately gauged copper conductors to handle the 10A continuous load without excessive voltage drop. During commissioning, use the front-mounted adjustment potentiometer to fine-tune the output voltage to suit specific field device requirements. For enhanced system reliability, integrate the DC-OK signal into your PLC's alarm logic to provide immediate notification of any power interruption.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe compact footprint of the 1606-XL120DR allows engineers to maximize rail space in standard DIN rail enclosures. Its high efficiency ratings translate directly to lower operational costs and reduced thermal stress on adjacent components, such as PLCs and I\/O modules. The 1606-XL series' robust transient protection ensures that the power supply remains operational even in environments prone to line noise and voltage spikes, providing a consistent \"clean\" power source for critical industrial electronics.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the output voltage of the 1606-XL120DR adjustable?\u003c\/strong\u003e\u003cbr\u003e\nA1: Yes, the unit features a front-facing potentiometer that allows for precise adjustments of the output voltage to compensate for line loss or to meet the specific needs of specialized hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the benefit of the pluggable terminal system?\u003c\/strong\u003e\u003cbr\u003e\nA2: Pluggable terminals allow for the pre-wiring of harnesses and permit the rapid replacement of the power supply without disconnecting individual wires, significantly reducing MTTR (Mean Time To Repair).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module support parallel operation for increased current?\u003c\/strong\u003e\u003cbr\u003e\nA3: The 1606-XL series typically supports various redundancy and parallel configurations; however, it is recommended to consult the specific series wiring diagram to ensure proper load sharing and thermal management.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050726424708,"sku":"1606-XL120DR","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1606-XL120DR-2.jpg?v=1778772432"},{"product_id":"allen-bradley-powerflex-4m-22f-b1p6n103-3-phase-240v-drive","title":"Allen-Bradley PowerFlex 4M 22F-B1P6N103 3-Phase 240V Drive","description":"\u003ch2 style=\"color: #303f9f;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #303f9f;\"\u003e22F-B1P6N103\u003c\/strong\u003e is a highly efficient and compact AC drive from the Allen-Bradley PowerFlex 4M family. Engineered for global versatility, this 0.2 kW (0.25 HP) drive provides high-speed motor control for three-phase systems with an output frequency range up to 400 Hz. Its \"Frame A\" design is specifically built to save valuable panel space while offering powerful performance for small machinery. With a net weight of approximately 1.0 kg (2.2 lbs), it delivers a robust yet lightweight solution for precise automation tasks.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cp\u003eThis module is built for demanding startups, offering a 150% overload capacity for up to 60 seconds. It utilizes advanced V\/Hz control to maintain consistent motor torque across its entire frequency range. The hardware is designed without an internal CE filter to maintain a slim footprint, making it ideal for localized applications where external filtering is managed separately. Its IP20 open-style enclosure supports a 240V input and provides 1.6A of continuous current, ensuring reliable operation in ambient temperatures up to 50°C.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eFeature\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eDetails\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003ePower Rating\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.2 kW (0.25 HP)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOutput Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.6 A\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eInput Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e200-240V AC, 3-Phase\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFrequency Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0 - 400 Hz\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eProduct Weight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1.0 kg (Approx. 2.2 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOverload Capacity\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e150% for 60 Seconds\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003cp\u003eDue to its compact 1.0 kg design, the unit can be easily panel-mounted using standard DIN rail or mounting screws. The feed-through wiring architecture simplifies cabinet layout by keeping power lines at the top and motor leads at the bottom. To ensure long-term reliability, maintain clear space around the IP20 chassis for natural convection cooling. Periodically verify the terminal torque settings to prevent heat buildup from loose connections, especially in high-vibration industrial environments.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003eThe PowerFlex 4M series allows for seamless integration into existing Rockwell Automation architectures. This 1.6A model is particularly effective for small fans, pumps, and conveyor systems that require high precision in a minimal physical footprint. Its built-in RS485 communication supports Modbus RTU, enabling remote parameterization and diagnostic monitoring without the need for additional communication cards, significantly reducing total system cost.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #303f9f;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the physical weight of this drive?\u003c\/strong\u003e\u003cbr\u003eA1: The module weighs approximately 1.0 kg (2.2 lbs), making it an exceptionally lightweight and easy-to-install component.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Does this unit include a CE-compliant filter?\u003c\/strong\u003e\u003cbr\u003eA2: No, this model (103 suffix) is designed without an internal CE filter to minimize size and cost; external filters can be added if required for your specific application.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the maximum output frequency?\u003c\/strong\u003e\u003cbr\u003eA3: The drive can provide an output frequency of up to 400 Hz, suitable for high-speed motor applications.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050727702660,"sku":"22F-B1P6N103","price":126.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22F-B1P6N103-1.jpg?v=1778505645"},{"product_id":"allen-bradley-powerflex-523-drive-25a-v4p8n104-new","title":"Allen-Bradley PowerFlex 523 Drive 25A-V4P8N104 | New","description":"\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 25A-V4P8N104\u003c\/strong\u003e is a versatile AC drive from the \u003cstrong\u003ePowerFlex 523\u003c\/strong\u003e series, engineered to provide high-performance motor control for standalone machines. This \u003cstrong\u003e1.0 HP (0.75 kW)\u003c\/strong\u003e Variable Frequency Drive (VFD) is specifically designed to accept a single-phase 120V AC input and deliver a three-phase 230V AC output, making it an ideal solution for facilities with limited power infrastructure. Its modular design and MainsFree™ configuration allow for rapid installation and simplified programming, ensuring your induction motors operate with maximum efficiency.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #ddd; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eBrand \/ Series\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eAllen-Bradley \/ PowerFlex 523\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003ePart Number\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e25A-V4P8N104\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOutput Power\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.0 HP (0.75 kW)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eOutput Current\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e4.8 Amps\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eInput Voltage\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e85-132V AC (Single-Phase)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFrame Size\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eFrame B\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eEnclosure Rating\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIP20 (NEMA Open Type)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eCommunication\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eIntegrated RS485 \/ USB Port\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #ddd; padding: 10px;\"\u003e1.1 kg (2.4 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #333;\"\u003eModular Design \u0026amp; Simplified Setup\u003c\/h3\u003e\n\u003cp\u003eThe 25A-V4P8N104 features a unique \u003cstrong\u003emodular architecture\u003c\/strong\u003e where the control module can be detached from the power module. This allows for simultaneous wiring and software configuration via the \u003cstrong\u003eMainsFree™ USB connection\u003c\/strong\u003e, significantly accelerating the commissioning process for system integrators.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eCompact Footprint \u0026amp; Flexible Mounting\u003c\/h3\u003e\n\u003cp\u003eOccupying a compact \u003cstrong\u003e170 x 120 x 150 mm\u003c\/strong\u003e space, this Frame B drive supports Zero-Stacking™ mounting. By eliminating the need for airflow gaps between drives, you can minimize total cabinet size while maintaining reliable operation in ambient temperatures up to +50°C.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eComprehensive Motor Protection\u003c\/h3\u003e\n\u003cp\u003eEquipped with advanced protection features, the drive proactively safeguards your equipment against \u003cstrong\u003eoverloads, short-circuits, and thermal runaway\u003c\/strong\u003e. The integrated Safe-Torque Off (STO) functionality provides an additional layer of safety for personnel and machinery during maintenance or emergency stops.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eInstallation \u0026amp; Configuration Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Connect the 120V single-phase input to the L1 and N terminals. Ensure the three-phase motor is correctly wired to the U, V, and W terminals to prevent phase imbalance.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install in a vertical orientation within a clean, dry IP20-rated enclosure. For high-vibration environments, ensure the panel mount screws are torqued to manufacturer specifications.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConfiguration:\u003c\/strong\u003e Utilize the standard Human Interface Module (HIM) for local adjustments or use a USB cable to connect to a PC for comprehensive parameter backup and cloning using Connected Components Workbench™ software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the 25A-V4P8N104 run on a 230V input?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: No, this specific model is designed for a nominal 120V single-phase input range (85-132 VAC). Applying 230V to the input terminals will damage the power module.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does this drive include internal EMC filtering?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: The \"N104\" suffix indicates that no internal EMC filter is included. If your application requires compliance with specific electromagnetic interference standards, an external filter must be installed.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is this drive compatible with Logix controllers?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: Yes, the PowerFlex 523 series seamlessly integrates with CompactLogix and ControlLogix systems via the RS485 port or an optional dual-port EtherNet\/IP™ adapter for high-speed industrial networking.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050728652932,"sku":"25A-V4P8N104","price":120.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/25A-V4P8N104.jpg?v=1778163679"},{"product_id":"allen-bradley-25a-b017n104-powerflex-523-ac-drive-3-phase-240vac-4kw","title":"Allen-Bradley 25A-B017N104 PowerFlex 523 AC Drive 3-Phase 240VAC 4kW","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eAllen-Bradley 25A-B017N104\u003c\/strong\u003e is a flagship model within the PowerFlex 523 series, engineered to provide versatile and cost-effective motor control for standalone machines. Rated for 5HP (4.0 kW) at 240V, this drive excels in providing precise speed regulation through multiple control methods, ensuring high performance for a wide array of industrial applications while maintaining a compact Frame B footprint.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #003366;\"\u003eModel Series:\u003c\/strong\u003e Allen-Bradley PowerFlex 523\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #003366;\"\u003eVoltage Class:\u003c\/strong\u003e 200-240V AC, 3-Phase (Input range: 170-264 VAC).\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #003366;\"\u003eControl Architecture:\u003c\/strong\u003e Volts per Hertz (V\/Hz), Sensorless Vector Control (SVC), and SVC with Economizer for reduced energy consumption.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong style=\"color: #003366;\"\u003eEnclosure \u0026amp; Mounting:\u003c\/strong\u003e IP20 NEMA \/ Open Type enclosure designed for streamlined panel mounting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n            \u003cth style=\"border: 1px solid #dddddd; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #dddddd; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eOutput Power\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e4.0 kW \/ 5.0 HP\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eOutput Current\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e17.5 Amps\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eOutput Frequency\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e0 to 400 Hz\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eFrame Size\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eFrame B\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eDimensions\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e188 x 140 x 160 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003eWeight\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #dddddd; padding: 10px;\"\u003e2.25 kg (4.96 lbs)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003ePerformance \u0026amp; Safety Features\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIntegrated Safety:\u003c\/strong\u003e Features Safe-Torque Off (STO) functionality to help protect personnel and equipment while meeting global safety standards.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eBraking Power:\u003c\/strong\u003e Includes a built-in IGBT for dynamic motor braking, eliminating the need for external braking modules in many applications.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eUser Interface:\u003c\/strong\u003e Comes standard with an integrated Human Interface Module (HIM) for easy local configuration and diagnostics.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eFlexible I\/O:\u003c\/strong\u003e Includes 5 discrete inputs, 1 analog input, and 1 relay output for seamless integration into complex control logic.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e The Sensorless Vector Control with Economizer mode automatically adjusts to the motor load to reduce energy costs.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eEase of Integration:\u003c\/strong\u003e Built-in RS485 (DSI) communication port allows for easy networking and multi-drive configurations.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCompact Power:\u003c\/strong\u003e The \u003cstrong style=\"color: #003366;\"\u003e25A-B017N104\u003c\/strong\u003e provides 5HP capacity in a standard Frame B size, maximizing power density in small enclosures.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the weight of the 25A-B017N104 drive?\u003c\/strong\u003e\u003cbr\u003e\nA1: The unit has a net weight of approximately 2.25 kg (4.96 lbs), making it lightweight and easy to install on standard panels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum output frequency of this drive?\u003c\/strong\u003e\u003cbr\u003e\nA2: The \u003cstrong style=\"color: #003366;\"\u003e25A-B017N104\u003c\/strong\u003e supports a wide output frequency range from 0 Hz up to 400 Hz, suitable for high-speed motor applications.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is the Safe-Torque Off (STO) feature standard?\u003c\/strong\u003e\u003cbr\u003e\nA3: Yes, STO is integrated into this PowerFlex 523 model, providing a hardware-based safety circuit to prevent motor restarts.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050728685700,"sku":"25A-B017N104","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/25A-B017N104.jpg?v=1778079620"},{"product_id":"adjustable-frequency-drive-22f-d2p5n103-2-5a-allen-bradley","title":"Adjustable Frequency Drive 22F-D2P5N103 2.5A Allen-Bradley","description":"\u003ch2 style=\"color: #2c3e50; padding-bottom: 0; margin-top: 25px; margin-bottom: 15px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 30px;\"\u003e\n  The Allen-Bradley \u003cstrong style=\"color: #003366;\"\u003e22F-D2P5N103\u003c\/strong\u003e is a member of the PowerFlex 40P family, specifically engineered for applications that require enhanced control and flexibility in a space-saving design. Providing 0.75 kW (1 HP) of output power, this drive is tailored for 480V 3-phase motor systems. It stands out in the PowerFlex series for its expanded I\/O capabilities and superior communication flexibility. With its IP20 Open enclosure and specialized diagnostic array, the 22F-D2P5N103 ensures consistent performance and rapid troubleshooting for industrial automation and motion control.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\n\u003ch3 style=\"color: #2c3e50; font-size: 1.1em; margin-bottom: 8px;\"\u003eComprehensive Diagnostic Interface\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 20px;\"\u003e\n  Equipped with 10 diagnostic LEDs, the 22F-D2P5N103 provides real-time visual feedback on operation status and fault conditions. This allows maintenance teams to identify issues instantly without needing external tools for basic troubleshooting, significantly reducing machine downtime.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c3e50; font-size: 1.1em; margin-bottom: 8px;\"\u003eVersatile Communication Options\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 20px;\"\u003e\n  While featuring a built-in RS-485 port for standard integration, this drive is designed to scale with your network needs. It supports optional communication cards for various high-level protocols including Ethernet\/IP, ProfiBus, DeviceNet, and BacNet, ensuring compatibility with virtually any industrial control architecture.\n\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c3e50; font-size: 1.1em; margin-bottom: 8px;\"\u003eFlexible I\/O Integration\u003c\/h3\u003e\n\u003cp style=\"line-height: 1.5; color: #000000; margin-bottom: 35px;\"\u003e\n  The drive offers 5 discrete inputs that can be configured as either sink or source, along with a Form C discrete output. Combined with an analog input that accepts both 0-10V DC and 0-20mA signals, it provides the versatility needed for complex control sequences and sensor integration.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-bottom: 40px; border: 1px solid #dfe4e8; color: #000000;\"\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold; width: 40%;\"\u003eModel Number\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e22F-D2P5N103\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003ePower Output\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e1.0 HP \/ 0.75 kW\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eOutput Current\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e2.5 Amps\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eInput Voltage\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e340-528 VAC (3-Phase)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eProduct Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e1.41 kg (Approx.)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eI\/O Count\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003e5 Discrete Inputs \/ 1 Form C Output\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f4f6f8;\"\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eEnclosure Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003eIP20 \/ NEMA Open Type\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8; font-weight: bold;\"\u003eCE Filter\u003c\/td\u003e\n      \u003ctd style=\"padding: 10px; border: 1px solid #dfe4e8;\"\u003eNot Installed\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eInstallation \u0026amp; Safety Guidelines\u003c\/h2\u003e\n\u003cul style=\"line-height: 1.6; color: #000000; margin-bottom: 40px;\"\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for internal panel mounting. Ensure the surrounding environment stays within the operating temperature range of 0°C to 40°C.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Supports 3-phase input only. Verify that the input voltage matches the 480V class specification (340-528 VAC) before powering the unit.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFiltering:\u003c\/strong\u003e This specific model is supplied without a CE-compliant filter. If your application requires strict EMC compliance, an external filter should be installed.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2c3e50; margin-top: 35px; margin-bottom: 15px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2c3e50;\"\u003eQ1: What makes the PowerFlex 40P different from the 4M series?\u003c\/p\u003e\n\u003cp style=\"margin-top: 0; margin-bottom: 15px; color: #000000;\"\u003eA1: The 40P (Performance) series offers more advanced control features, a higher I\/O count, and a more robust diagnostic LED array compared to the 4M (Micro) series, making it better suited for complex automation.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2c3e50;\"\u003eQ2: Can I use this drive on a single-phase power supply?\u003c\/p\u003e\n\u003cp style=\"margin-top: 0; margin-bottom: 15px; color: #000000;\"\u003eA2: No, the 22F-D2P5N103 requires a 3-phase input. Attempting to run on single-phase will likely trigger a phase loss fault or damage the input rectifier bridge.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 4px; font-weight: bold; color: #2c3e50;\"\u003eQ3: How do I implement Ethernet\/IP communication with this model?\u003c\/p\u003e\n\u003cp style=\"margin-top: 0; margin-bottom: 20px; color: #000000;\"\u003eA3: You must install an optional 22-COMM-E Ethernet\/IP adapter. The built-in port is restricted to RS-485 (Modbus RTU) protocols.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050729046148,"sku":"22F-D2P5N103","price":130.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/22F-D2P5N103.jpg?v=1777381481"},{"product_id":"allen-bradley-1784-kt-communication-interface-module","title":"Allen-Bradley 1784-KT Communication Interface Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eALLEN-BRADLEY 1784-KT\u003c\/strong\u003e is a specialized Communication Interface Module designed to facilitate high-speed data exchange between host computers and Allen-Bradley industrial controllers. Supporting Data Highway Plus (DH+), PLC-2, and PLC-3 protocols, this module acts as a vital bridge for legacy system integration and real-time monitoring. Engineered for precision, it is a lightweight component with a net weight of only 0.34 kg, making it a low-profile yet powerful addition to industrial communication networks.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Configuration\u003c\/h2\u003e\n\u003ch3\u003eVersatile Communication Protocols\u003c\/h3\u003e\n\u003cp\u003eThe 1784-KT supports both asynchronous and synchronous communication modes. For PLC-2 and PLC-3 systems, it handles asynchronous baud rates of 9600 and 19.2 Kbps. When operating on a Data Highway Plus network, it achieves a synchronous transfer rate of 57.6 Kbps. This versatility allows for short-range local connections (up to 10 ft) or extensive long-distance industrial networking.\u003c\/p\u003e\n\u003ch3\u003eLong-Distance Networking \u0026amp; Reliability\u003c\/h3\u003e\n\u003cp\u003eOne of the primary advantages of the 1784-KT is its ability to maintain signal integrity over vast distances. When configured for Data Highway Plus with PLC-3 or PLC-5 controllers, the module supports communication cable lengths of up to 10,000 feet (3,050 meters). It operates on a dual-voltage DC power requirement, drawing only 2W at +5V DC and less than 0.5W at 12V DC, ensuring minimal thermal impact on the host system.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 25px 0; border: 1px solid #e0e0e0; font-family: inherit;\"\u003e\n    \u003cthead\u003e\n        \u003ctr style=\"background-color: #f4f4f4;\"\u003e\n            \u003cth style=\"border: 1px solid #e0e0e0; padding: 15px; text-align: left; font-size: 15px; color: #333;\"\u003eTechnical Parameter\u003c\/th\u003e\n            \u003cth style=\"border: 1px solid #e0e0e0; padding: 15px; text-align: left; font-size: 15px; color: #333;\"\u003eDetailed Rating\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa; width: 40%;\"\u003e\u003cstrong\u003ePower Requirement (5V)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e+5V DC @ 0.4A (2W)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003ePower Requirement (12V)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e12V DC @ 0.04A (0.48W)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eDH+ Baud Rate\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e57.6 Kbps (Synchronous)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eMax Distance (DH+)\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e10,000 ft (3,050 meters)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e0°C to 55°C (32°F to 130°F)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px; background-color: #fafafa;\"\u003e\u003cstrong\u003eProduct Weight\u003c\/strong\u003e\u003c\/td\u003e\n            \u003ctd style=\"border: 1px solid #e0e0e0; padding: 12px; font-size: 14px;\"\u003e0.34 kg (0.75 lbs)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eEnvironmental \u0026amp; Operational Stability\u003c\/h2\u003e\n\u003cp\u003eThe 1784-KT is built to withstand standard industrial floor conditions, with an operating humidity range of 5% to 95% (non-condensing). Its thermal design allows for continuous operation in temperatures up to 55°C (130°F). Because of its legacy compatibility, it remains a critical component for maintaining older PLC-2 and PLC-3 installations while providing a pathway to more modern PLC-5 Data Highway Plus networks.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLegacy Connectivity:\u003c\/strong\u003e Provides rare support for PLC-2 and PLC-3 asynchronous communication, preserving existing infrastructure.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHigh Power Efficiency:\u003c\/strong\u003e Consumes less than 2.5W of total power, reducing the electrical load on the host computer or interface rack.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eProven DH+ Performance:\u003c\/strong\u003e Industry-standard 57.6 Kbps synchronous speed ensures reliable data packets for complex automation tasks.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eExtended Reach:\u003c\/strong\u003e Capable of spanning over 3 kilometers of cable without the need for repeaters on DH+ networks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the maximum distance for a PLC-2 connection?\u003c\/strong\u003e\u003cbr\u003e\nA1: For PLC-2 and PLC-3 asynchronous connections, the maximum cable distance is limited to 10 feet (3 meters).\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Does the 1784-KT support PLC-5?\u003c\/strong\u003e\u003cbr\u003e\nA2: Yes, it supports PLC-5 controllers via the Data Highway Plus (DH+) network protocol at 57.6 Kbps.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: Is any external power supply required?\u003c\/strong\u003e\u003cbr\u003e\nA3: No, the module typically draws its +5V and 12V DC power directly from the host interface slot it is installed in.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050729635972,"sku":"1784-KT","price":187.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1784-KT-2.jpg?v=1776947319"},{"product_id":"1769-aentr-allen-bradley-compact-i-o-ethernet-comm-module","title":"1769-AENTR Allen-Bradley Compact I\/O Ethernet Comm Module","description":"\u003ch2 id=\"product-overview\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2b579a; font-size: 1.1em;\"\u003eAllen-Bradley 1769-AENTR\u003c\/strong\u003e is a high-performance CompactLogix EtherNet\/IP adapter designed to provide a reliable bridge between 1769 Compact I\/O modules and an Ethernet network. Featuring \u003cstrong\u003edual 10\/100 Mbps Ethernet ports\u003c\/strong\u003e with an embedded switch, this module supports Device Level Ring (DLR) and linear topologies, significantly reducing the need for external switches. With the capacity to handle up to \u003cstrong\u003e128 simultaneous EtherNet\/IP connections\u003c\/strong\u003e, it is an ideal solution for distributed I\/O applications in automotive, packaging, and water treatment industries.\u003c\/p\u003e\n\u003ch2 id=\"technical-configuration\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e Allen-Bradley (Rockwell Automation)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFull Model:\u003c\/strong\u003e \u003cspan style=\"color: #2b579a;\"\u003e\u003cstrong\u003e1769-AENTR\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication:\u003c\/strong\u003e Dual-port EtherNet\/IP (Embedded Switch)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection Capacity:\u003c\/strong\u003e 128 EtherNet\/IP \/ 96 TCP\/IP\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Draw:\u003c\/strong\u003e 500mA at 5V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e 35mm DIN rail or Panel Mount\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e 1769 Compact I\/O Modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 id=\"technical-specifications\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; border: 1px solid #cccccc; margin-bottom: 20px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e0°C to 60°C (32°F to 140°F)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eUnit Weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e\u003cstrong\u003e0.28 kg (approx. 0.62 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eNetwork Speed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e10\/100 Mbps (Auto-negotiation)\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eIP Addressing\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eRotary Switches \/ DHCP \/ BOOTP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eI\/O Banks\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003eUp to 3 Banks of 1769 I\/O\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc; background-color: #f9f9f9;\"\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #cccccc;\"\u003e30V Continuous (Basic Insulation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2 id=\"key-features-benefits\"\u003eKey Features \u0026amp; Operational Benefits\u003c\/h2\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Network Resiliency with DLR:\u003c\/strong\u003e The 1769-AENTR supports \u003cstrong\u003eDevice Level Ring (DLR)\u003c\/strong\u003e topology. This allows the network to maintain communication even if a single cable break occurs, increasing uptime in critical machine automation and material handling systems without the cost of redundant hardware.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. Simplified Architecture:\u003c\/strong\u003e By eliminating the need for standalone Ethernet switches between every module, the 1769-AENTR reduces panel space and wiring costs. Its integrated switch simplifies the daisy-chaining of distributed I\/O drops, making it easier to integrate remote racks into a single Logix platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Seamless Migration:\u003c\/strong\u003e This adapter protects existing I\/O investments by allowing users to upgrade their controllers to newer Logix processors while keeping their existing 1769 I\/O modules. Remote monitoring and diagnostics are enabled immediately through its robust Ethernet connectivity.\u003c\/p\u003e\n\u003ch2 id=\"installation-guide\"\u003eInstallation Guidelines\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMounting:\u003c\/strong\u003e Mount the unit on a standard 35mm DIN rail. Ensure the module is securely latched using the DIN rail mounting clip. When connecting to the 1769 backplane, ensure the tongue-and-groove slots are aligned before sliding the modules together.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNetwork Setup:\u003c\/strong\u003e Use Category 5e (or better) shielded twisted-pair cables. Set the unique IP address using the three rotary switches (range 001-254) for quick manual setup, or set them to 888 for a factory reset.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eClearance:\u003c\/strong\u003e Maintain at least \u003cstrong\u003e50mm (2 in)\u003c\/strong\u003e of clearance on all sides to allow for proper heat dissipation. This is critical for maintaining the 60°C maximum operating temperature rating in high-density enclosures.\u003c\/p\u003e\n\u003ch2 id=\"technical-faqs\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O modules can a single 1769-AENTR support?\u003c\/strong\u003e\u003cbr\u003eA: It can support up to 30 modules across three I\/O banks, depending on the power supply capacity and the specific requirements of the connected modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does it support Power over Ethernet (PoE)?\u003c\/strong\u003e\u003cbr\u003eA: No, the 1769-AENTR requires a separate 5V DC power source, typically provided through the 1769 CompactLogix backplane and power supply.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can I use the two ports for different subnets?\u003c\/strong\u003e\u003cbr\u003eA: No, the dual ports act as an unmanaged switch on the same subnet, intended for daisy-chaining or DLR ring configurations.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050730160260,"sku":"1769-AENTR","price":223.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/1769-AENTR.jpg?v=1776863109"},{"product_id":"bently-nevada-330130-045-01-00-armored-coaxial-cable","title":"Bently Nevada 330130-045-01-00 Armored Coaxial Cable","description":"\u003ch2 style=\"color: #2f4f4f;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\n  The \u003cstrong\u003eBently Nevada 330130-045-01-00\u003c\/strong\u003e is a high-performance 3300 XL standard extension cable designed to bridge the gap between proximity probes and Proximitor® sensors. This 4.5-meter (14.8 feet) cable is engineered for maximum signal integrity in critical machinery protection systems. Featuring a robust armored exterior, it is specifically built to endure the mechanical stresses and harsh chemical exposures typical of industrial power plants, refineries, and manufacturing facilities.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eTechnical Configuration\u003c\/h2\u003e\n\u003cp\u003e\n  This 330130 model is configured for enhanced physical protection and medium-reach connectivity:\n\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eFull Model:\u003c\/strong\u003e 330130-045-01-00\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Series:\u003c\/strong\u003e 3300 XL Standard Extension Cable.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCable Length (045):\u003c\/strong\u003e 4.5 meters (14.8 feet) total length.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Protection (01):\u003c\/strong\u003e Integrated stainless steel armor jacket for maximum durability.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAgency Approval (00):\u003c\/strong\u003e Standard configuration (No specialized country approvals required).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eConnector Type:\u003c\/strong\u003e Miniature coaxial connectors with ClickLoc™ technology.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #ddd; padding: 8px; text-align: left;\"\u003eSpecification Detail\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eProduct Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e0.323 kg\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCable Impedance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e75 Ω (Standard for 3300 XL series)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eMaterial (Armor)\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eFlexible Stainless Steel Armor\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eInsulation Material\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003ePerfluoroalkoxy (PFA) for high chemical resistance\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eCapacitance\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eStandardized for 5m\/9m total system calibration\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003eOperating Temperature\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #ddd; padding: 8px;\"\u003e-51°C to +177°C (-60°F to +350°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003cp\u003e\n  When installing the \u003cstrong\u003e330130-045-01-00\u003c\/strong\u003e, ensure that the ClickLoc™ connectors are clean and dry before mating. The armored jacket allows for routing through areas where the cable may be subject to abrasion or light crushing; however, always maintain the minimum bend radius to avoid damaging the internal coaxial core. This 4.5m cable is typically used in a 5-meter system (paired with a 0.5m probe) or a 9-meter system (paired with a 4.5m probe) to match the calibration of the Proximitor® sensor.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cp\u003e\n  The primary advantage of the 330130 armored cable is its \u003cstrong\u003eEnvironmental Resilience\u003c\/strong\u003e. The stainless steel armor prevents \"wicking\" of fluids and protects the signal from EMI\/RFI interference when grounded correctly. Its 75 Ω impedance is precisely matched to the Bently Nevada 3300 XL series, ensuring that the displacement signal remains linear and free from distortion over the entire 4.5-meter span. The PFA insulation ensures the cable remains flexible and functional even after years of exposure to industrial oils and high temperatures.\n\u003c\/p\u003e\n\n\u003ch2 style=\"color: #2f4f4f;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\n  \u003cstrong\u003eQ1: Why choose the armored (01) version over the standard unarmored cable?\u003c\/strong\u003e\u003cbr\u003e\n  A1: The armored version is essential in environments where the cable is exposed to foot traffic, sharp metal edges, or potential physical impacts, significantly reducing the risk of signal loss due to cable severance.\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cstrong\u003eQ2: Can this 4.5m cable be used with any Bently Nevada probe?\u003c\/strong\u003e\u003cbr\u003e\n  A2: It is designed for use with the 3300 XL series. To maintain calibration accuracy, the combined length of the probe lead and extension cable must match the Proximitor’s rated system length (typically 5m or 9m).\n\u003c\/p\u003e\n\u003cp\u003e\n  \u003cstrong\u003eQ3: Does the armor protect against moisture?\u003c\/strong\u003e\u003cbr\u003e\n  A3: While the armor provides mechanical protection, the internal PFA insulation and ClickLoc seals provide the moisture barrier. The armor is \"perforated\" for flexibility and is not intended to be a liquid-tight conduit.\n\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050736484484,"sku":"330130-045-01-00","price":194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330130-045-01-00-3.jpg?v=1776866561"},{"product_id":"bently-nevada-330130-080-00-cn-extension-cable","title":"Bently Nevada 330130-080-00-CN | Extension Cable","description":"\u003ch2\u003eProduct Identification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eManufacturer: Bently Nevada\u003c\/li\u003e\n\u003cli\u003ePart Number: \u003cstrong\u003e330130-080-00-CN\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eProduct Type: 3300 XL Standard Extension Cable\u003c\/li\u003e\n\u003cli\u003eOrigin: Made in USA\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003ePhysical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eLength: 8.0 meters (26.2 feet) ±1% tolerance\u003c\/li\u003e\n\u003cli\u003eWeight: 0.272 kg (34 g\/m | 0.4 oz\/ft)\u003c\/li\u003e\n\u003cli\u003eConductor Material: Oxygen-free copper, 0.75 mm² cross-section\u003c\/li\u003e\n\u003cli\u003eShielding: 8-layer shielding for industrial environments\u003c\/li\u003e\n\u003cli\u003eConnector Protector: IP67-rated dust and water resistance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eElectrical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eVoltage Rating: 300V AC\/DC maximum\u003c\/li\u003e\n\u003cli\u003eCurrent Capacity: 10A\u003c\/li\u003e\n\u003cli\u003eInsulation Resistance: ≥20 MΩ at 500V DC\u003c\/li\u003e\n\u003cli\u003eInsertion Loss: ≤0.5 dB at 100 MHz\u003c\/li\u003e\n\u003cli\u003eSignal Integrity: High-performance data transmission\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eEnvironmental Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOperating Temperature: -40°C to 105°C\u003c\/li\u003e\n\u003cli\u003eFlex Life: 5000+ bend cycles minimum\u003c\/li\u003e\n\u003cli\u003eLightweight Design: 34 g\/m reduces installation stress\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications \u0026amp; Compliance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAgency Approval: CN = Country Specific Approval\u003c\/li\u003e\n\u003cli\u003eCE Compliant\u003c\/li\u003e\n\u003cli\u003eRoHS Compliant\u003c\/li\u003e\n\u003cli\u003eREACH Compliant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e3300 Series monitoring systems\u003c\/li\u003e\n\u003cli\u003e3500 Series monitoring systems\u003c\/li\u003e\n\u003cli\u003e3300 XL proximity probe systems\u003c\/li\u003e\n\u003cli\u003eGenuine Bently Nevada replacement part\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e8-layer shielding for noise immunity\u003c\/li\u003e\n\u003cli\u003eIP67-rated connector protection\u003c\/li\u003e\n\u003cli\u003e5000+ bend cycle durability\u003c\/li\u003e\n\u003cli\u003e-40°C to 105°C wide temperature range\u003c\/li\u003e\n\u003cli\u003eOxygen-free copper for signal quality\u003c\/li\u003e\n\u003cli\u003eLightweight 0.272 kg design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFAQ\u003c\/h2\u003e\n\u003ch3\u003eWhat is the length and weight of \u003cstrong\u003e330130-080-00-CN\u003c\/strong\u003e?\u003c\/h3\u003e\n\u003cp\u003e8.0 meters (26.2 feet) with 0.272 kg total weight at 34 g\/m density.\u003c\/p\u003e\n\u003ch3\u003eWhat certifications does this cable hold?\u003c\/h3\u003e\n\u003cp\u003eCE, RoHS, and REACH compliant with CN country-specific approvals.\u003c\/p\u003e\n\u003ch3\u003eWhat is the temperature range?\u003c\/h3\u003e\n\u003cp\u003e-40°C to 105°C with IP67-rated connector protection.\u003c\/p\u003e\n\u003ch2\u003eContact Information\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEmail: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050736976004,"sku":"330130-080-00-CN","price":111.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330130-080-00-CN.jpg?v=1779464919"},{"product_id":"bently-nevada-3500-series-power-supply-3500-15-05-05-02","title":"Bently Nevada 3500 Series Power Supply 3500\/15-05-05-02","description":"\u003ch2\u003e\u003cb\u003eBently Nevada 3500\/15-05-05-02 Power Supply\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cb\u003eBently Nevada 3500\/15-05-05-02\u003c\/b\u003e is a universal AC power module. It provides reliable power for 3500 series monitoring systems. This ATEX-certified unit operates in hazardous locations.\u003c\/p\u003e\n\u003ch2\u003e\u003cb\u003eProduct Specifications\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eManufacturer \u0026amp; Model:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e\u003cb\u003eBently Nevada 3500\/15-05-05-02\u003c\/b\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003ePart Number:\u003c\/b\u003e 3500\/15-05-05-02\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eInput Voltage:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e85-264V AC universal range\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eConfiguration:\u003c\/b\u003e Dual-slot (top and bottom) power supply\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eCertifications:\u003c\/b\u003e ATEX, IECEx, CSA (Class 1, Zone 2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eEfficiency:\u003c\/b\u003e 90% high-efficiency rating\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModule Dimensions:\u003c\/b\u003e 120.7 x 50.8 x 251.5 mm\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eModule Weight:\u003c\/b\u003e 1.39 kg (3.06 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eOperating Temperature:\u003c\/b\u003e \u003cspan style=\"color: #d9534f;\"\u003e-30°C to +65°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eKey Features\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eUniversal AC input (85-264V) for global compatibility\u003c\/li\u003e\n\u003cli\u003eDual power slots for redundant operation\u003c\/li\u003e\n\u003cli\u003eATEX\/IECEx certification for hazardous areas\u003c\/li\u003e\n\u003cli\u003e90% high efficiency reduces energy costs\u003c\/li\u003e\n\u003cli\u003eComplete protection: overvoltage, overcurrent, short-circuit\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range (-30°C to +65°C)\u003c\/li\u003e\n\u003cli\u003eHot-swappable design for maintenance without downtime\u003c\/li\u003e\n\u003cli\u003eCompact footprint fits standard 3500 chassis\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eEnvironmental \u0026amp; Safety Ratings\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOperating temperature: -30°C to +65°C (-22°F to +150°F)\u003c\/li\u003e\n\u003cli\u003eStorage temperature: -40°C to +85°C (-40°F to +185°F)\u003c\/li\u003e\n\u003cli\u003eHumidity tolerance: 95% non-condensing\u003c\/li\u003e\n\u003cli\u003eHazardous area certification: ATEX\/IECEx Zone 2\u003c\/li\u003e\n\u003cli\u003eNorth American certification: CSA Class 1, Division 2\u003c\/li\u003e\n\u003cli\u003eDesigned for industrial vibration monitoring systems\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003ePackage Contents\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eOne \u003cb\u003eBently Nevada 3500\/15-05-05-02\u003c\/b\u003e power supply\u003c\/li\u003e\n\u003cli\u003ePower Input Module (PIM) for installation\u003c\/li\u003e\n\u003cli\u003eAll necessary mounting hardware\u003c\/li\u003e\n\u003cli\u003eCertification documentation and manuals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eShipping \u0026amp; Delivery\u003c\/b\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eExpress shipping: FedEx, UPS, DHL available\u003c\/li\u003e\n\u003cli\u003eInternational hazardous goods certified shipping\u003c\/li\u003e\n\u003cli\u003ePackage tracking provided for all orders\u003c\/li\u003e\n\u003cli\u003eStandard delivery: 5-10 business days worldwide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cb\u003eFAQ\u003c\/b\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eWhat makes this model different from standard 3500\/15?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eThe \u003cb\u003e3500\/15-05-05-02\u003c\/b\u003e has universal AC input and ATEX certification. It operates safely in explosive atmospheres (Zone 2).\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eCan this power supply work with any voltage?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eYes. Its universal input accepts 85-264V AC automatically. No manual voltage switching is required.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eIs this suitable for offshore oil platforms?\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003eAbsolutely. The ATEX\/IECEx certification makes it ideal for offshore and petrochemical applications with hazardous areas.\u003c\/p\u003e\n\u003cp\u003eContact: \u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0722\/7280\/6146\/files\/3500-15.pdf?v=1740032258\" target=\"_blank\"\u003eDownload Full Specifications PDF\u003c\/a\u003e\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050739662980,"sku":"3500\/15-05-05-02","price":180.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3500_15-05-05-02.jpg?v=1769910053"},{"product_id":"new-bently-nevada-330103-00-07-10-01-05-proximity-probe","title":"New Bently Nevada 330103-00-07-10-01-05 Proximity Probe","description":"\u003ch2 style=\"font-weight: bold; color: #0056b3; margin-top: 20px;\"\u003eBently Nevada 330103-00-07-10-01-05 Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eBently Nevada 330103-00-07-10-01-05\u003c\/strong\u003e is a high-precision 3300 XL 8mm proximity probe engineered for continuous, industrial-grade machinery monitoring and vibration detection. Featuring a rugged 70mm stainless steel unthreaded housing coupled with a Polyphenylene Sulfide (PPS) tip, this metric probe delivers exceptional chemical and environmental resistance. It provides stable eddy current measurement paths across an active range of 0.25 to 2.3 mm (10 to 90 mils), yielding a highly accurate linear voltage output mapping from -1 to -17 Vdc. Weighing approximately 323g\/m, it is heavily favored for mission-critical deployments across volatile, hazardous industrial environments.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #004085; margin-top: 25px;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #0056b3; margin-top: 15px;\"\u003eExcellent Thermal \u0026amp; Chemical Endurance\u003c\/h3\u003e\n\u003cp\u003eThe sensor assembly withstands extreme temperature ranges, supporting standard probe operation from -62°F to +350°F (-52°C to +177°C). The robust PPS tip construction protects the internal sensing coils against corrosive machine fluids and lubricants.\u003c\/p\u003e\n\u003ch3 style=\"color: #004085; margin-top: 15px;\"\u003eSecure ClickLoc Micro-Coaxial Connection\u003c\/h3\u003e\n\u003cp\u003eEquipped with an integrated 1.0-meter coaxial cable terminating in a specialized miniature coaxial ClickLoc connector with a built-in connector protector. This mechanism provides a robust, vibration-resistant locking joint that prevents signal attenuation or intermittent connection dropouts caused by high-frequency machinery harmonics.\u003c\/p\u003e\n\u003ch3 style=\"color: #004085; margin-top: 15px;\"\u003eHazardous Area Classification\u003c\/h3\u003e\n\u003cp\u003eFully certified for global hazardous area operation under ATEX, IECEx, and CSA standards (Agency Approval Option 05). It is rated for Zone 0 (AEx\/Ex ia IIC T5...T1 Ga) intrinsically safe installations as well as Zone 2 (AEx\/Ex nA\/ec IIC T5...T1 Gc) safe-operating schemas spanning Groups A through G.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #004085; margin-top: 25px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin-top: 10px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2; text-align: left;\"\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; border: 1px solid #ddd;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Model\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e330103-00-07-10-01-05\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eProduct Series Architecture\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e3300 XL 8mm Proximity Transducer System (Metric)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eManufacturer \/ Brand\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eBently Nevada (Baker Hughes)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eHousing Sizes\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e70mm overall case length; 00mm unthreaded length; M10×1 mechanical thread\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eLinear Measurement Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e2 mm (80 mils) linear span; from 0.25 to 2.3 mm (10 to 90 mils)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eDynamic Signal Output\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-1 Vdc to -17 Vdc linear voltage scale\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eOptimal Sensor Gap Calibration\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e-9 Vdc electrical bias point (matching 50 mils \/ 1.27 mm center gap)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eElectrical Resistive Accuracy\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e7.59 Ω ± 0.50 Ω nominal tolerance bounds\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eIntegrated Cable Layout\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e1.0-meter (3.3 feet) standard coaxial line with miniature ClickLoc connector and protector\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eHumidity \u0026amp; Environmental Drift\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e\u0026lt;3% Average Scale Factor (ASF) change when exposed to 93% RH for up to 56 days\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eNet Mass Weight\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003e323 grams per meter (approx. 0.323 kg\/m density profile)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd; font-weight: bold;\"\u003eExplosion Protection Codes\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #ddd;\"\u003eZone 0: AEx\/Ex ia IIC T5...T1 Ga | Zone 2: AEx\/Ex nA\/ec IIC T5...T1 Gc\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #004085; margin-top: 25px;\"\u003eInstallation \u0026amp; Engineering Guide\u003c\/h2\u003e\n\u003ch3 style=\"color: #004085; margin-top: 15px;\"\u003eMechanical Alignment and Gap Setup\u003c\/h3\u003e\n\u003cp\u003eMount the 70mm probe body securely through the machine casing wall using the M10×1 thread profile, ensuring a maximum length of thread engagement of 15 mm. Adjust the physical gap distance relative to the target shaft surface until your digital voltmeter registers exactly -9 Vdc at the Proximitor sensor output terminal, validating the perfect 50 mils center operating gap.\u003c\/p\u003e\n\u003ch3 style=\"color: #004085; margin-top: 15px;\"\u003eField Extension Wiring Parameters\n\u003c\/h3\u003e\u003cp\u003eWhen extending the sensor loop to your central control cabinet or monitoring rack, use a 3-conductor shielded triad wire layout (0.2 to 1.5 mm² or 16 to 24 AWG recommended). Keep the total field extension length restricted within a maximum wiring threshold of 305 meters (1,000 feet) between the 3300 XL Proximitor Sensor and the monitor to manage high-frequency signal rolloff.\u003c\/p\u003e\n\u003ch3 style=\"color: #004085; margin-top: 15px;\"\u003eEnvironmental Limitations \u0026amp; Sealing\u003c\/h3\u003e\n\u003cp\u003eThe module features premium differential pressure sealing between the probe tip and case utilizing a Viton® O-ring. However, these units are not pressure tested prior to shipment; contact the custom design department if application-specific verification is required. Avoid exposing the coaxial assembly to temperatures below -34°C (-30°F) to prevent premature failure of the pressure seal.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #004085; margin-top: 25px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What does the 323g\/m physical weight specification imply for field engineering?\u003c\/strong\u003e\u003cbr\u003e\nA1: The 323g\/m rating indicates the exact hardware density profile of the combined probe body and shielded coaxial line, giving installation engineers structural data for calculating strain relief bracket loads on long cable runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can the 330103-00-07-10-01-05 probe handle high-pressure fluid environments out of the box?\u003c\/strong\u003e\u003cbr\u003e\nA2: While it features an integrated Viton® O-ring assembly for robust differential pressure isolation, the default configuration is not pressure-tested prior to shipment. Specific custom pressure testing must be requested manually.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How does high relative humidity affect the operational accuracy of this 8mm probe?\u003c\/strong\u003e\u003cbr\u003e\nA3: The probe features a hermetically sealed assembly that restricts the Average Scale Factor (ASF) drift to less than 3% even under continuous exposure to 93% relative humidity conditions for up to 56 days per IEC standard 68 2 3.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":51050743627908,"sku":"330103-00-07-10-01-05","price":194.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/330103-00-07-10-01-05.jpg?v=1782395733"}],"url":"https:\/\/www.etowonauto.com\/collections\/featured-products.oembed?page=12","provider":"Etowon Auto","version":"1.0","type":"link"}