{"product_id":"v18345-2010421001-abb-tzidc-positioner-analog-feedback","title":"V18345-2010421001 | ABB TZIDC Positioner Analog Feedback","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0066cc;\"\u003eV18345-2010421001\u003c\/strong\u003e is a TZIDC electro-pneumatic positioner from ABB, designed for precise valve control on linear and rotary actuators. Features 4–20 mA two-wire input, HART communication, double-acting fail-safe output, and plug-in analog position feedback (4–20 mA). Aluminum IP65\/NEMA 4X housing. Weight: 1.7 kg.\u003c\/p\u003e\n\u003ch3\u003eAnalog Position Feedback Module\u003c\/h3\u003e\n\u003cp\u003eRange 4–20 mA with configurable split ranges. Two-wire circuitry, power supply 24 V DC (10–30 V DC) or 48 V DC (20–48 V DC, no explosion protection). Action direct or reverse (configurable). Characteristic deviation \u0026lt;1%. Without a signal from the positioner, the module sets output to \u0026gt;20 mA (alarm level).\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003eV18345-2010421001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eTZIDC Electro-Pneumatic Positioner\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4–20 mA (two-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eHART, LKS local connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput \/ Safe Position\u003c\/td\u003e\n\u003ctd\u003eDouble acting, fail safe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Position Feedback\u003c\/td\u003e\n\u003ctd\u003e4–20 mA, configurable split ranges\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC (10–30 V DC) \/ 48 V DC (20–48 V DC, non-Ex)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Deviation\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Pressure\u003c\/td\u003e\n\u003ctd\u003e1.4–6 bar (20–90 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Consumption\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.03 kg\/h \/ 0.015 scfm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eAluminum, varnished, RAL 9005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Connections\u003c\/td\u003e\n\u003ctd\u003eG 1\/4 or 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003eCable: 1\/2-14 NPT; Air pipe: 1\/4-18 NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input\u003c\/td\u003e\n\u003ctd\u003e0–5 V DC (logical 0), 11–30 V DC (logical 1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output\u003c\/td\u003e\n\u003ctd\u003e5–11 V DC (NAMUR DIN 19234)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation \u0026amp; Maintenance\u003c\/h2\u003e\n\u003ch3\u003eMounting\u003c\/h3\u003e\n\u003cp\u003eMount to linear actuators per DIN\/IEC 534\/NAMUR or rotary actuators per VDI\/VDE 3845. Mechanical position indicator provides visual feedback. Mounting orientation has no measurable influence on performance.\u003c\/p\u003e\n\u003ch3\u003eAir Supply\u003c\/h3\u003e\n\u003cp\u003eUse instrument air free of oil, water, and dust. Supply pressure 1.4–6 bar (20–90 psi). Do not exceed actuator max operating pressure. Air consumption \u0026lt;0.03 kg\/h independent of supply pressure.\u003c\/p\u003e\n\u003ch3\u003eElectrical Connection\u003c\/h3\u003e\n\u003cp\u003eConnect 4–20 mA two-wire signal. HART communication via 20 mA signal line. Analog position feedback module provides 4–20 mA output proportional to valve position. Cable entry: 1\/2-14 NPT.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eDouble-Acting Fail-Safe\u003c\/h3\u003e\n\u003cp\u003eFail-safe output moves actuator to safe position on electrical power failure. For double-acting actuators, output 1 is depressurized and output 2 is pressurized, ensuring reliable safety operation.\u003c\/p\u003e\n\u003ch3\u003eIntegrated Analog Feedback\u003c\/h3\u003e\n\u003cp\u003ePlug-in analog position feedback module (4–20 mA) provides accurate valve position indication. Configurable split ranges and direct\/reverse action. Outputs \u0026gt;20 mA alarm level when no positioner signal is present.\u003c\/p\u003e\n\u003ch3\u003eRobust Environmental Protection\u003c\/h3\u003e\n\u003cp\u003eIP65\/NEMA 4X aluminum housing with electrostatic epoxy varnish resists corrosion and dust. Mechanical position indicator and HART communication enable easy commissioning and remote diagnostics.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the fail-safe behavior on electrical power failure?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA1:\u003c\/strong\u003e Double-acting fail-safe. Output 1 is depressurized and the valve moves to its safe position. The second output is additionally pressurized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Does this model include analog position feedback?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. The plug-in analog position feedback module provides 4–20 mA output with configurable split ranges and \u0026lt;1% deviation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What supply pressure range does this positioner require?\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA3:\u003c\/strong\u003e 1.4–6 bar (20–90 psi). Do not exceed the maximum operating pressure of the actuator.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":68134751273092,"sku":"V18345-2010421001","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/V18345-2010421001.jpg?v=1795527818","url":"https:\/\/www.etowonauto.com\/az\/products\/v18345-2010421001-abb-tzidc-positioner-analog-feedback","provider":"Etowon Auto","version":"1.0","type":"link"}