{"product_id":"schneider-140noa62200-interbus-master","title":"Schneider 140NOA62200 Interbus Master","description":"\u003ch2\u003eSchneider Electric Modicon Quantum \u003cstrong\u003e140NOA62200\u003c\/strong\u003e Interbus Master Module Generation 4 – PCP V2.0\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003e140NOA62200\u003c\/strong\u003e is an Interbus master module from the Schneider Electric Modicon Quantum automation platform. This \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eGeneration 4 Interbus master\u003c\/span\u003e features \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003ePCP V2.0 profile\u003c\/span\u003e and operates at \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e500 kbit\/s\u003c\/span\u003e via isolated RS485 interface. It is compatible with Quantum CPUs including 140CPU11303, 140CPU43412A, and 140CPU53414B.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eInterbus master module\u003c\/span\u003e Generation 4 with PCP V2.0\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e500 kbit\/s\u003c\/span\u003e transmission rate via \u003cspan style=\"color: #3498db;\"\u003eisolated RS485\u003c\/span\u003e (DIN 66020)\u003c\/li\u003e\n\u003cli\u003eSupports \u003cspan style=\"color: #c41e3a;\"\u003e6 x 140CPU11303\u003c\/span\u003e or \u003cspan style=\"color: #2e8b57;\"\u003e2 x 140CPU43412A\/140CPU53414B\u003c\/span\u003e in local rack\u003c\/li\u003e\n\u003cli\u003eExtensive memory: \u003cspan style=\"color: #3498db;\"\u003e128 kB + 256 kB firmware EPROM\u003c\/span\u003e, \u003cspan style=\"color: #c41e3a;\"\u003e256 kB + 32 kB data RAM\u003c\/span\u003e, \u003cspan style=\"color: #2e8b57;\"\u003e64 kB command EEPROM\u003c\/span\u003e, \u003cspan style=\"color: #3498db;\"\u003e64 kB multi-port RAM\u003c\/span\u003e, \u003cspan style=\"color: #c41e3a;\"\u003e2 kB dual-port RAM\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e12 LED indicators\u003c\/span\u003e for comprehensive status monitoring\u003c\/li\u003e\n\u003cli\u003eBus current requirement: \u003cspan style=\"color: #3498db;\"\u003e800 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower dissipation: \u003cspan style=\"color: #c41e3a;\"\u003e4 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cspan style=\"color: #2e8b57;\"\u003eConcept and ProWORX 32\u003c\/span\u003e software (V2.5 SR2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db;\"\u003eCSA and UL\u003c\/span\u003e certified\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e Schneider Electric\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e Modicon Quantum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e140NOA62200\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Interbus Master Module (Generation 4)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Profile:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003ePCP V2.0\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eInterbus RS485 isolated\u003c\/span\u003e @ 500 kbit\/s (DIN 66020)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMethod of Access:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003eMaster\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eTwisted pair\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Cable Distance:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e20 m\u003c\/span\u003e (65.6 ft)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Current Requirement:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e800 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e4 W\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Format:\u003c\/strong\u003e Standard\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack Type:\u003c\/strong\u003e Local\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Connection:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e2 x SUB-D 9\u003c\/span\u003e (one for Interbus link)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Weight:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0.9 kg\u003c\/span\u003e (2.0 lb)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE Marking:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eMemory Configuration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003e128 kB + 256 kB\u003c\/span\u003e firmware EPROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e2 kB\u003c\/span\u003e dual-port RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db;\"\u003e256 kB + 32 kB\u003c\/span\u003e data RAM\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003e64 kB\u003c\/span\u003e Interbus command sequence EEPROM\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e64 kB\u003c\/span\u003e multi-port RAM\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eLED Indicators\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eGreen LEDs:\u003c\/span\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eACTIVE - Communication with Quantum CPU\u003c\/li\u003e\n\u003cli\u003eRUN - Firmware and module running\u003c\/li\u003e\n\u003cli\u003eIS-B RUN - Interbus functioning normally with data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003eRed LEDs:\u003c\/span\u003e\u003c\/li\u003e\n\u003cul\u003e\n\u003cli\u003eF - Module fault\u003c\/li\u003e\n\u003cli\u003eDEA 202 - Initialization fault\u003c\/li\u003e\n\u003cli\u003eInterbus master not operational\u003c\/li\u003e\n\u003cli\u003eInterbus module fault reported\u003c\/li\u003e\n\u003cli\u003eMemory fault\u003c\/li\u003e\n\u003cli\u003ePeripheral bus fault\u003c\/li\u003e\n\u003cli\u003eProcessor fault (master)\u003c\/li\u003e\n\u003cli\u003eRemote bus fault\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eYellow LED:\u003c\/span\u003e One or more bus segments shut down\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatible CPUs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003e140CPU11303\u003c\/span\u003e (up to 6 modules in local rack)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e140CPU43412A\u003c\/span\u003e (up to 2 modules in local rack)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #3498db;\"\u003e140CPU53414B\u003c\/span\u003e (up to 2 modules in local rack)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware Compatibility\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003eConcept\u003c\/span\u003e V2.5 SR2\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eProWORX 32\u003c\/span\u003e V2.5 SR2\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e0 to 60°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e-40 to 85°C\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e95%\u003c\/span\u003e without condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Altitude:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e≤ 5000 m\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance to Electrostatic Discharge:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e4 kV contact\u003c\/span\u003e, \u003cspan style=\"color: #3498db;\"\u003e8 kV air\u003c\/span\u003e (IEC 801-2)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResistance to Electromagnetic Fields:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e9.1 V\/m (10 V\/m)\u003c\/span\u003e 80-1000 MHz (IEC 801-3)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGTIN\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e00785901457145\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this Interbus master module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003e140NOA62200\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What CPUs are compatible with the \u003cstrong\u003e140NOA62200\u003c\/strong\u003e?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt is compatible with \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e140CPU11303 (up to 6 modules)\u003c\/span\u003e, \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e140CPU43412A and 140CPU53414B (up to 2 modules each)\u003c\/span\u003e in local rack configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What are the key LED indicators on this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe module features \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e12 LEDs\u003c\/span\u003e including green for CPU communication, module run, Interbus status; red for various faults; and yellow for bus segment shutdown.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":51549270081668,"sku":"140NOA62200","price":225.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/140NOA62200.jpg?v=1771572883","url":"https:\/\/www.etowonauto.com\/az\/products\/schneider-140noa62200-interbus-master","provider":"Etowon Auto","version":"1.0","type":"link"}