{"product_id":"mtl5014-dual-relay-interface-mtl-instruments","title":"MTL5014 Dual Relay Interface - MTL Instruments","description":"\u003ch2\u003e\u003cstrong\u003eMTL5014 Dual Relay Interface\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eMTL5014\u003c\/strong\u003e from MTL Instruments provides sophisticated control for hazardous area applications. This single-channel interface enables two safe-area loads to be controlled by one switch or proximity detector. It offers advanced features including line fault detection, phase reversal, and dual relay outputs for maximum flexibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Technical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eMTL Instruments\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e\u003cstrong\u003eMTL5014\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDual Relay Interface\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannels:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eOne input channel\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eTwo changeover relays\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10ms maximum\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHazardous Area Certification\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSwitch Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T6\u003c\/span\u003e hazardous area\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDetector Location:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eZone 0, IIC, T4-T6\u003c\/span\u003e with certification\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDivision Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eDivision 1, Group A\u003c\/span\u003e hazardous location\u003c\/li\u003e\n\u003cli\u003eThe \u003cstrong\u003eMTL5014\u003c\/strong\u003e maintains intrinsic safety for connected sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Standard:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eNAMUR\/DIN 19234\u003c\/span\u003e for proximity detectors\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e7.0 to 9.0V\u003c\/span\u003e from 1kΩ ±10% source\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNormal Phase:\u003c\/strong\u003e Output energizes if Iin \u0026gt;2.1mA or Rin \u0026lt;2kΩ\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReverse Phase:\u003c\/strong\u003e Output de-energizes under same conditions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHysteresis:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250µA typical\u003c\/span\u003e for stable switching\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhase Reversal:\u003c\/strong\u003e User selectable for output 1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eRelay Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelay Type:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eTwo single-pole changeover contacts\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating AC:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e250V AC, 2A, cosø \u0026gt;0.7\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Rating DC:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e40V DC, 2A, resistive load\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Life:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e300,000 operations\u003c\/span\u003e at maximum load\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eResponse Time:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10ms maximum\u003c\/span\u003e for fast control\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNote:\u003c\/strong\u003e Reactive loads require adequate suppression\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eLine Fault Detection (LFD)\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLFD Mode:\u003c\/strong\u003e User selectable - Off or On\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOpen Circuit Alarm:\u003c\/strong\u003e Activated if Iin \u0026lt; \u003cspan style=\"color: #2e75b6;\"\u003e100µA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShort Circuit Alarm:\u003c\/strong\u003e Activated if Iin \u0026gt; \u003cspan style=\"color: #2e75b6;\"\u003e6.5mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFault Response:\u003c\/strong\u003e De-energizes Output 1 relay\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eContact Input:\u003c\/strong\u003e Requires 500Ω-1kΩ series and 20kΩ-25kΩ parallel resistors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTerminal Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput:\u003c\/strong\u003e Terminal 1 (Input –ve), Terminal 2 (Input +ve)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarth Leakage:\u003c\/strong\u003e Terminal 3 for detection\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput 1:\u003c\/strong\u003e Terminal 10 (NC), 11 (Common), 12 (NO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOutput 2:\u003c\/strong\u003e Terminal 7 (NC), 8 (Common), 9 (NO)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply:\u003c\/strong\u003e Terminal 13 (Supply –ve), 14 (Supply +ve)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSupply Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e20 to 35V DC\u003c\/span\u003e operating range\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCurrent Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e45mA at 24V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e1.1W at 24V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Failure Protection:\u003c\/strong\u003e Built-in safety features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSafety Parameters\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e10.5V\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInternal Resistance:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e800Ω\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety Current:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003e14mA\u003c\/span\u003e maximum\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e75b6;\"\u003eUm = 250V rms or DC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHow many loads can the MTL5014 control?\u003c\/strong\u003e\u003cbr\u003eIt can control two independent safe-area loads from one hazardous area input.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is the line fault detection capability?\u003c\/strong\u003e\u003cbr\u003eIt detects both open circuits (\u0026lt;100µA) and short circuits (\u0026gt;6.5mA) in field wiring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCan I reverse the output logic?\u003c\/strong\u003e\u003cbr\u003eYes, Output 1 features user-selectable phase reversal operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat sensors are compatible?\u003c\/strong\u003e\u003cbr\u003eIt works with NAMUR proximity detectors and switches in hazardous areas.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"MTL","offers":[{"title":"Default Title","offer_id":51268255678596,"sku":"MTL5014","price":58.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/MTL5014.jpg?v=1762684492","url":"https:\/\/www.etowonauto.com\/az\/products\/mtl5014-dual-relay-interface-mtl-instruments","provider":"Etowon Auto","version":"1.0","type":"link"}