{"product_id":"ic670pbi001-profibus-biu-ge-fanuc-field-control-12m-baud","title":"IC670PBI001 Profibus BIU | GE Fanuc Field Control 12M Baud","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #003366;\"\u003eGE Fanuc IC670PBI001\u003c\/strong\u003e is a high-performance Profibus Bus Interface Unit (BIU) designed for the Field Control series of modular, distributed I\/O systems. Operating on a 24V DC external power supply (18–30V DC range), this module serves as the central communication gateway, interfacing up to \u003cstrong\u003eeight (8) Field Control I\/O modules\u003c\/strong\u003e to a host CPU via a high-speed Profibus DP network. Constructed with a rugged, compact aluminum housing, the unit features an approximate weight of \u003cstrong\u003e0.36 kg (0.8 lbs)\u003c\/strong\u003e. Equipped with a standard 9-pin D-sub Profibus network port and a dedicated 9-pin D-sub Hand-Held Programmer (HHP) port, the IC670PBI001 supports selectable transmission speeds up to \u003cstrong\u003e12 Mbits\u003c\/strong\u003e. Mounted directly to a Bus Interface Terminal Block, it enables convenient hot-swappable module replacement without disturbing field wiring.\u003c\/p\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable border=\"1\" style=\"width: 100%; border-collapse: collapse; margin-bottom: 20px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #003366; color: white;\"\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProduct Catalog Number\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003eIC670PBI001\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eManufacturer \/ Product Family\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eGE Fanuc \/ Field Control Series\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProduct Type\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProfibus Bus Interface Unit (BIU)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eRated Input Voltage \u0026amp; Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e24 VDC Nominal (18 to 30 VDC Range)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eInput Power \u0026amp; Power Dissipation\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e7.7 Watts Input Power | 4.45 Watts Dissipation\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eSupported Protocol \u0026amp; Topology\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eProfibus DP | Linear Bus Topology (Daisy-Chain)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eTransmission Speeds\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e9.6K, 19.2K, 93.75K, 187.5K, 500K, 1.5M, 3M, 6M, and 12 Mbits\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eCommunication Ports\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e1x 9-Pin D-sub (Profibus Network), 1x 9-Pin D-sub (HHP Programmer)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eNode Addressing \u0026amp; Expansion Capacity\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eDIP Switches (Address 00–32) | Up to 8 I\/O Modules per BIU\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eApproximate Module Weight\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e\u003cstrong\u003e0.36 kg (0.8 lbs)\u003c\/strong\u003e\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eStatus LED Indicators\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003ePWR (Power), RUN, OK\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eHoldup Time \u0026amp; Reliability MTBF\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e10 ms Maximum Holdup Time | 180,000 Operating Hours MTBF\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f0f9ff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eMounting Options\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eDIN Rail or Panel Mount via BIU Terminal Block\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003eOperating Temperature Range\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #003366; padding: 8px;\"\u003e0°C to 55°C (32°F to 131°F)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eKey Hardware \u0026amp; Operational Features\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eIntelligent Distributed Processing:\u003c\/strong\u003e Manages scan processing, analog scaling, range selection, and I\/O fault reporting for up to 8 local Field Control I\/O modules.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh-Speed Communication:\u003c\/strong\u003e Supports flexible Profibus DP network transmission rates ranging from 9.6 Kbits up to 12 Mbits over shielded twisted-pair cabling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eModular Maintenance Architecture:\u003c\/strong\u003e Mounts on a dedicated BIU terminal base, allowing rapid module insertion and removal without disconnecting network or field wiring.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDedicated Programming Interface:\u003c\/strong\u003e Features a built-in 9-pin HHP port for local programming, diagnostic displays, program transfers, and I\/O forcing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Field Wiring Guidelines\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. Unit Mounting:\u003c\/strong\u003e Snap the BIU terminal block onto a standard DIN rail or secure it to a panel using mounting tabs. Seat the IC670PBI001 module firmly into the terminal base.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e2. Network \u0026amp; Hardware Setup:\u003c\/strong\u003e Set node address (00–32) using the 8-position DIP switch array. Connect the 9-pin D-sub Profibus cable, ensuring terminating resistors are enabled at end nodes.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e3. Power \u0026amp; Field Wiring:\u003c\/strong\u003e Wire external 24 VDC power to the terminal base. Verify line power protection via the onboard replaceable slow-blow fuse before energizing.\u003c\/p\u003e\n\n\u003ch2\u003eFrequently Asked Questions (FAQs)\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ1: How many I\/O modules can the IC670PBI001 support?\u003c\/strong\u003e\u003cbr\u003e\nA1: A single IC670PBI001 BIU module can host and manage up to 8 Field Control I\/O modules.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: How is the Profibus node address configured on this module?\u003c\/strong\u003e\u003cbr\u003e\nA2: Address range 00 to 32 is set manually via the 8-position DIP switch array on the unit.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What maximum baud rate does the IC670PBI001 support?\u003c\/strong\u003e\u003cbr\u003e\nA3: The module supports standard Profibus transmission speeds up to 12 Mbits.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":52655334555780,"sku":"IC670PBI001","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC670PBI001-1.jpg?v=1787061807","url":"https:\/\/www.etowonauto.com\/az\/products\/ic670pbi001-profibus-biu-ge-fanuc-field-control-12m-baud","provider":"Etowon Auto","version":"1.0","type":"link"}