{"product_id":"ic200mdl143-versamax-120v-isolated-module-ge-fanuc","title":"IC200MDL143 VersaMax 120V Isolated Module - GE Fanuc","description":"\u003ch2\u003eGE Fanuc VersaMax \u003cstrong\u003eIC200MDL143\u003c\/strong\u003e Discrete Input Module\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200MDL143\u003c\/strong\u003e is a discrete input module from the GE Fanuc VersaMax I\/O and Control System featuring \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e8 individually-isolated inputs\u003c\/span\u003e with \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e120 Volts AC operating voltage\u003c\/span\u003e. \u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e8 individually-isolated discrete inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e120V AC nominal voltage\u003c\/span\u003e (0-132V AC operating range)\u003c\/li\u003e\n\u003cli\u003eFrequency: \u003cspan style=\"color: #3498db;\"\u003e47-63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: #c41e3a;\"\u003ePositive logic\/sourcing-type inputs\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eMaximum backplane current: \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e50 mA @5V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOn-state voltage: \u003cspan style=\"color: #3498db;\"\u003e70-132V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eOff-state voltage: \u003cspan style=\"color: #c41e3a;\"\u003e0-20V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum on-state current: \u003cspan style=\"color: #2e8b57;\"\u003e5 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eMaximum on-state response time: \u003cspan style=\"color: #3498db;\"\u003e1 cycle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e1500V AC point-to-point isolation\u003c\/span\u003e (60 minutes)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e1500V AC ground isolation\u003c\/span\u003e (1 minute)\u003c\/li\u003e\n\u003cli\u003eDimensions: \u003cspan style=\"color: #3498db;\"\u003e110 x 66.8 x 50.0 mm\u003c\/span\u003e (4.3 x 2.63 x 1.956 in)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eIC200MDL143\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDescription:\u003c\/strong\u003e Discrete Input Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication:\u003c\/strong\u003e Versamax I\/O and Control System\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Inputs:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e8 discrete inputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Type:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003ePositive logic \/ sourcing-type\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e120 Volts AC nominal\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Range:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0-132V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrequency:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e47-63 Hz\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOn-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e70-132V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOff-State Voltage:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e0-20V AC\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMinimum On-State Current:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e5 mA\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Response Time (On):\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e1 cycle\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Current Rating:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e50 mA @5V max\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003eYes - individually isolated\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePoint-to-Point Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e1500V AC for 60 minutes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Isolation:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e1500V AC for 1 minute\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBuilt-in Power:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eYes - from backplane\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLocation:\u003c\/strong\u003e Versamax I\/O Carriers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: How many inputs does the \u003cstrong\u003eIC200MDL143\u003c\/strong\u003e have and are they isolated?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt has \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e8 individually-isolated discrete inputs\u003c\/span\u003e with 1500V AC point-to-point isolation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the voltage range and power requirement?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt operates at \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e120V AC nominal\u003c\/span\u003e (0-132V AC, 47-63 Hz) and draws \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e50 mA @5V from backplane\u003c\/span\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What isolation ratings does this module provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt provides \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003e1500V AC point-to-point isolation for 60 minutes\u003c\/span\u003e and \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e1500V AC ground isolation for 1 minute\u003c\/span\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050823745668,"sku":"IC200MDL143","price":216.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200MDL143.jpg?v=1771643174","url":"https:\/\/www.etowonauto.com\/az\/products\/ic200mdl143-versamax-120v-isolated-module-ge-fanuc","provider":"Etowon Auto","version":"1.0","type":"link"}