{"product_id":"ge-fanuc-ic200gbi001-genius-versamax-network-unit","title":"GE Fanuc IC200GBI001 Genius VersaMax Network Unit","description":"\u003ch2\u003eGE Fanuc VersaMax \u003cstrong\u003eIC200GBI001\u003c\/strong\u003e Genius Network Interface Unit (NIU)\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eIC200GBI001\u003c\/strong\u003e is a Genius Network Interface Unit (NIU) from the VersaMax PLC product family, manufactured by Emerson Automation (formerly GE Fanuc). This \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eGenius slave module\u003c\/span\u003e hosts and controls I\/O modules for implementing \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003edistributed I\/O architecture\u003c\/span\u003e. It supports up to \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e8 racks with 8 I\/O modules per rack\u003c\/span\u003e (64 total modules).\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eGenius Network Interface Unit (NIU)\u003c\/span\u003e for VersaMax systems\u003c\/li\u003e\n\u003cli\u003eFunctions as \u003cspan style=\"color: #2e8b57;\"\u003eGenius slave module\u003c\/span\u003e hosting I\/O modules\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e8 racks with 8 modules per rack\u003c\/span\u003e (64 total)\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003eDual Genius terminals\u003c\/span\u003e for primary and redundant connections\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003eRedundancy supported\u003c\/span\u003e for hardware and media\u003c\/li\u003e\n\u003cli\u003eTransmission rates: \u003cspan style=\"color: #3498db;\"\u003e153.6 kbaud, 76.8 kbaud, 38.4 kbaud\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eDiscrete I\/O capacity: \u003cspan style=\"color: #c41e3a;\"\u003e1024 inputs + 1024 outputs\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eAnalog I\/O memory: \u003cspan style=\"color: #2e8b57;\"\u003e128 bytes input + 128 bytes output\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompatible with \u003cspan style=\"color: #3498db;\"\u003eSeries 90-70, PACSystem RX7i, RX3i\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #c41e3a;\"\u003eDaisy-chain wiring topology\u003c\/span\u003e with terminating resistors\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan style=\"color: #2e8b57;\"\u003e7 LED indicators\u003c\/span\u003e for comprehensive status monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e GE Fanuc \/ GE Intelligent Platforms \/ Emerson Automation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeries:\u003c\/strong\u003e VersaMax\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eIC200GBI001\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e Genius Network Interface Unit (NIU)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Ports:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e2 Genius terminals\u003c\/span\u003e (primary + redundant)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003eSupported\u003c\/span\u003e (hardware and media)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum Racks:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e8\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModules per Rack:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e8\u003c\/span\u003e (64 total modules maximum)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Inputs\/Bus Scan:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e128 bytes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Outputs\/Bus Scan:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e128 bytes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete I\/O Memory:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e1024 points\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Inputs:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e1024\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiscrete Outputs:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e1024\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAnalog I\/O Memory:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003e128 bytes\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTransmission Rates:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e153.6 kbaud\u003c\/span\u003e (extended), \u003cspan style=\"color: #c41e3a;\"\u003e153.6\/76.8\/38.4 kbaud\u003c\/span\u003e (standard)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Topology:\u003c\/strong\u003e \u003cspan style=\"color: #2e8b57;\"\u003eDaisy-chain\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminating Resistor:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e75, 100, 120, or 150 ohms\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Consumption:\u003c\/strong\u003e \u003cspan style=\"color: #c41e3a;\"\u003e250 mA @5V\u003c\/span\u003e, \u003cspan style=\"color: #2e8b57;\"\u003e10 mA @3.3V\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSerial Bus Address Range:\u003c\/strong\u003e \u003cspan style=\"color: #3498db;\"\u003e0 to 31\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible Controllers:\u003c\/strong\u003e Series 90-70, PACSystem RX7i, PACSystem RX3i\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Types:\u003c\/strong\u003e Fiber-optic, Shielded Twisted Pair (STP)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePackage Includes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1x GE Fanuc \u003cstrong\u003eIC200GBI001\u003c\/strong\u003e Genius Network Interface Unit\u003c\/li\u003e\n\u003cli\u003e1x installation guide\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the part number for this Genius Network Interface Unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe part number is \u003cstrong style=\"color: #c41e3a;\"\u003eIC200GBI001\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. How many I\/O modules can the \u003cstrong\u003eIC200GBI001\u003c\/strong\u003e support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports up to \u003cspan style=\"color: #2e8b57; font-weight: bold;\"\u003e8 racks with 8 I\/O modules per rack\u003c\/span\u003e, totaling 64 modules maximum.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. What transmission rates are available and what redundancy features does it have?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports \u003cspan style=\"color: #3498db; font-weight: bold;\"\u003e153.6 kbaud, 76.8 kbaud, and 38.4 kbaud\u003c\/span\u003e with \u003cspan style=\"color: #c41e3a; font-weight: bold;\"\u003edual Genius terminals for hardware and media redundancy\u003c\/span\u003e.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51050839441540,"sku":"IC200GBI001","price":148.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/IC200GBI001.jpg?v=1771566416","url":"https:\/\/www.etowonauto.com\/az\/products\/ge-fanuc-ic200gbi001-genius-versamax-network-unit","provider":"Etowon Auto","version":"1.0","type":"link"}