{"product_id":"flex-5000-16-point-ac-input-module-allen-bradley-5094-ia16","title":"FLEX 5000 16 Point AC Input Module Allen-Bradley 5094-IA16","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003e5094-IA16\u003c\/strong\u003e is a high-density 16-point AC Input Module manufactured by Allen-Bradley for the advanced FLEX 5000 I\/O platform. Operating at a nominal voltage of 120V AC with a permissible input threshold spanning 74 to 132V AC, this module provides premium digital signaling interface capabilities for demanding heavy industrial processes. Weighing just 0.136 kg, its compact distributed footprint brings high-speed, reliable sensor data logging closer to the field, minimizing extensive wiring trunks back to the central control panel.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eOptimized High-Density Layout:\u003c\/strong\u003e Features 16 distinct AC input channels within a single slim module block, reducing total rail real estate and lowering hardware cabinet costs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eAdvanced Controller Interoperability:\u003c\/strong\u003e Integrates seamlessly with high-performance Logix control platforms including CompactLogix 5380, ControlLogix 5580, and GuardLogix 5580 safety controllers via Studio 5000 Logix Designer application (version 31 or higher).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSevere Temperature Resilience:\u003c\/strong\u003e Engineered to sustain flawless logic execution across an extended operational ambient range from -20°C to +70°C, ensuring ultimate reliability in unconditioned remote outposts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; padding: 8px; text-align: left;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5094-IA16\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNumber of Inputs\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 Channels (Sinking\/Sourcing)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e120V AC (47 to 63 Hz)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eOperating Voltage Range\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e74 to 132V AC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eInput Current \/ Impedance\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e5 to 15 mA \/ 8.8 to 12 kΩ\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eSignal Delay (Max)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eOn Delay: 15 ms | Off Delay: 25 ms\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eIsolation Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e250V AC continuous isolation barrier\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModule Power Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e3.5 Watts\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eProduct Net Weight\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e0.136 kg (0.30 lbs)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eIndustrial Applications\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePackaging Machine Line Controls:\u003c\/strong\u003e Monitors interlocking proximity arrays, photo-eye sensors, and limit switches for high-speed cartoning and wrapping gear.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eMaterial Handling Systems:\u003c\/strong\u003e Detects auxiliary motor-starter feedback, e-stop reset confirmations, and divert-gate positions along complex distribution conveyors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eProcess Fluid Infrastructure:\u003c\/strong\u003e Tracks primary valve open\/closed limit switches and heavy-duty line pump operational status readouts.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnvironmental Safety Triggers:\u003c\/strong\u003e Interfaces directly with high-voltage industrial oven door micro-switches and safety boundary curtains.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eWiring \u0026amp; Installation\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSafety Compliance:\u003c\/strong\u003e Ensure all upstream power feeds are fully isolated and locked out before seating the module into the terminal base assembly or attaching conductor pairs.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSignal Conductor Sizing:\u003c\/strong\u003e Connect field signal loops using standard 0.34 to 2.5 mm² (22 to 14 AWG) solid or stranded wiring terminations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Supply Termination:\u003c\/strong\u003e Utilize a dedicated 2.5 mm² multi-strand wire for the main power input lines. Connect across two dedicated power ports and two signal ports for stable voltage reference distribution.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNoise Abatement:\u003c\/strong\u003e Benefit from an integrated common-mode rejection filter rating of 50 dB minimum to neutralize inductive electromagnetic noise generated by nearby motor lines.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRugged Electrical Isolation:\u003c\/strong\u003e The 250V AC continuous isolation protective envelope prevents severe electrical surge migration from damaging delicate backplane logic circuits.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Thermal Capacity:\u003c\/strong\u003e Operates consistently across a wide temperature span (-20°C to +70°C), eliminating local enclosure panel cooling gear demands in hot plant bays.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eEnhanced Diagnostics:\u003c\/strong\u003e The built-in filtering circuit mitigates AC line jitter, ensuring crisp signal transitions with predictable, determinable propagation delay schedules.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What software version is mandatory to discover and configure the 5094-IA16?\u003c\/strong\u003e\u003cbr\u003e\nA1: You must implement Rockwell Automation Logix Designer software version 31 or higher to access the hardware profiles and setup parameters for the FLEX 5000 series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is this module capable of handling 24V DC input signals?\u003c\/strong\u003e\u003cbr\u003e\nA2: No. The 5094-IA16 is strictly configured for AC voltage inputs, featuring a lower turn-on threshold of 74V AC. For 24V DC field instrumentation, utilize the 5094-IB16 module instead.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the backplane voltage requirements for the module's primary logic chip?\u003c\/strong\u003e\u003cbr\u003e\nA3: The internal communication circuitry runs via a stable 15V DC track supplied by the underlying FLEX 5000 terminal base interface bus.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51050722361476,"sku":"5094-IA16","price":150.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5094-IA16-1.jpg?v=1779373430","url":"https:\/\/www.etowonauto.com\/az\/products\/flex-5000-16-point-ac-input-module-allen-bradley-5094-ia16","provider":"Etowon Auto","version":"1.0","type":"link"}