{"product_id":"fc-tidi-1624-honeywell-16-channel-input-module","title":"FC-TIDI-1624 Honeywell 16-Channel Input Module","description":"\u003ch2\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #0056b3;\"\u003eFC-TIDI-1624\u003c\/strong\u003e (general type FS-TIDI-1624) is a premium 16-channel Field Termination Assembly (FTA) module designed for Honeywell Safety Manager systems. This module acts as the specialized physical interface for non-safe isolated 24V DC input channels, seamlessly routing signals between external field wiring and system interconnection cables. Engineered for high-density control environments, it enables reliable monitoring of digital field inputs while offering robust galvanic isolation and high-frequency switching capabilities to safeguard central processing units.\u003c\/p\u003e\n\n\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRedundant Configuration Ready:\u003c\/strong\u003e Interfaces smoothly with SDI-1624 input modules via standard SICC-0001\/Lx system interconnection cables to support fault-tolerant redundant architectures.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSuperior Galvanic Isolation:\u003c\/strong\u003e Provides high-integrity 1000V AC isolation both input-to-output and input-to-input, preventing electrical faults or surges from cascading through the system.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRobust Reverse Polarity Protection:\u003c\/strong\u003e Utilizes an integrated series diode configuration capable of withstanding a maximum reverse voltage of 300V, minimizing field-wiring human errors.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrecise Voltage Thresholds:\u003c\/strong\u003e Features clear electrical parameters with a pick-up voltage of 17.5V DC and a drop-out voltage of 2.8V DC to eliminate false signal reporting.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"border: 1px solid #dddddd; text-align: left; padding: 8px;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eFC-TIDI-1624 \/ FS-TIDI-1624\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNumber of Channels\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e16 Non-Safe Isolated Input Channels\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eNominal Input Voltage\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e24V DC (Max. Input Voltage: 47.5V DC)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eVoltage Thresholds\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003ePick-up: 17.5V DC \/ Drop-out: 2.8V DC\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eInput Current \/ Frequency\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eTypically 9mA at 24V DC \/ Max. Switching Frequency: 20Hz\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eGalvanic Isolation\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e1000V AC (Input-to-Output \u0026amp; Input-to-Input)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eField Terminations\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eScrew terminals, max 2.5 mm² (AWG 14), 7mm strip length\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eMounting Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eDIN EN rails: TS32 \/ TS35 × 7.5\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eDimensions (L x W x H)\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e265 × 70 × 48 mm\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n      \u003ctd style=\"border: 1px solid #dddddd; padding: 8px;\"\u003eCE, TUV, UL, CSA\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch2\u003eInstallation \u0026amp; Maintenance Guide\u003c\/h2\u003e\n\u003ch3\u003eField Wiring Termination\u003c\/h3\u003e\n\u003cp\u003eConnect field wires using the onboard screw terminals. Strip the wires exactly to 7 mm and ensure the wire diameter does not exceed 2.5 mm² (AWG 14). Tighten the terminal screws to a specific torque of 0.5 Nm to prevent over-tightening or loose contacts that create signal chatter.\u003c\/p\u003e\n\n\u003ch3\u003eDIN Rail Mounting and Space Alignment\u003c\/h3\u003e\n\u003cp\u003eSnap the compact assembly securely onto standard DIN EN rails, supporting both TS32 and TS35 × 7.5 profiles. Maintain clean horizontal orientation and ensure adequate routing space for the thick SICC-0001\/Lx system interconnection cables to prevent physical tension on the module headers.\u003c\/p\u003e\n\n\u003ch3\u003eSystem Connection \u0026amp; Redundancy\u003c\/h3\u003e\n\u003cp\u003ePlug the system interconnection cable (SICC-0001\/Lx) into the module to bridge data back to the SDI-1624 input modules. For redundant system operation, ensure both parallel routing links are firmly engaged and verified within the Safety Manager hardware configuration setup.\u003c\/p\u003e\n\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExtended Mechanical Longevity:\u003c\/strong\u003e Built to endure rigorous processing life with an expected 1,000,000 electrical switch operations and up to 10,000,000 mechanical switch operations.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHigh Noise Immunity:\u003c\/strong\u003e High-threshold galvanic separation reduces industrial ground loop noise and crosstalk between adjacent input channels inside complex control cabinets.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eGlobal Standards Certified:\u003c\/strong\u003e Carries verified CE, TUV, UL, and CSA certifications, making it fully compliant with strict international safety laws and industrial project regulations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: What is the primary purpose of the series diode inside the FC-TIDI-1624?\u003c\/strong\u003e\u003cbr\u003e\nA1: The series diode acts as a hardwired reverse polarity protection mechanism. It safeguards the module by blocking backward current up to a maximum reverse voltage rating of 300V.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can this module handle fast-pulsing digital inputs?\u003c\/strong\u003e\u003cbr\u003e\nA2: The module supports a maximum switching frequency of 20Hz, making it ideal for standard industrial status contacts, limit switches, and level indicators, but not for high-speed pulse counters.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: How is redundancy achieved using this specific Field Termination Assembly?\u003c\/strong\u003e\u003cbr\u003e\nA3: The FC-TIDI-1624 establishes common multi-channel links through the SICC-0001\/Lx interconnection cable. This allows a dual set of SDI-1624 input modules to read the exact same field wiring points simultaneously for true hardware redundancy.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51864169513092,"sku":"FC-TIDI-1624","price":294.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-TIDI-1624.jpg?v=1779003536","url":"https:\/\/www.etowonauto.com\/az\/products\/fc-tidi-1624-honeywell-16-channel-input-module","provider":"Etowon Auto","version":"1.0","type":"link"}