{"product_id":"fc-sdo-04110-honeywell-safety-manager-110v-do-card","title":"FC-SDO-04110 Honeywell Safety Manager 110V DO Card","description":"\u003ch2 style=\"color: #1a365d; font-size: 14pt; margin-top: 0; margin-bottom: 12px;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eThe Honeywell \u003cstrong style=\"color: #1a365d;\"\u003eFC-SDO-04110\u003c\/strong\u003e is a high-integrity safe digital output module designed for Safety Manager and FSC control architectures. It features four independent 110 V DC solid-state source channels engineered to drive high-voltage resistive or inductive safety loops up to 35 W. Built specifically for critical fail-safe applications, this short-circuit proof module handles challenging industrial loads with extreme predictability. By integrating rigorous self-testing routines and dedicated hardware protection, it maintains continuous loop visibility and reliable control. Each high-voltage channel features integrated hardware safety functions that interface directly with central logic, ensuring precise execution of emergency shutdown commands in demanding environments like oil, gas, and power generation.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 16px; padding: 0; font-size: 0; line-height: 0;\"\u003e \u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 14pt; margin-bottom: 12px;\"\u003eCore Technical Advantages\u003c\/h2\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 6px;\"\u003eSecondary Means of De-energizing (SMOD)\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eThe module features an independent SMOD safety architecture. This critical layer allows the system watchdog and core processor to cut power to all output channels immediately and independently of application software state, guaranteeing shutdown capability even during processor faults.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 6px;\"\u003eFully Tested Internal Suppression\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eEvery channel includes built-in, factory-tested flyback suppression diodes. These internal components isolate and neutralize high-voltage back-EMF spikes caused by inductive loads like heavy solenoids, eliminating external panel snubbers while maintaining SIL compliance.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 16px;\"\u003eShort-Circuit Proof Solid-State Logic\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eThe rugged solid-state architecture provides electronic short-circuit protection across all 110 V DC lines. In the event of a field wiring short, the module instantly limits the current to protect its internal circuitry and neighboring channels from thermal stress.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 16px; padding: 0; font-size: 0; line-height: 0;\"\u003e \u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 14pt; margin-bottom: 12px;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\n\u003ctable style=\"width: 100%; border-collapse: collapse; min-width: 500px; margin-bottom: 16px;\"\u003e\n  \u003cthead\u003e\n    \u003ctr style=\"background-color: #f7fafc; border-bottom: 2px solid #cbd5e0;\"\u003e\n      \u003cth style=\"padding: 8px; text-align: left; font-weight: bold; color: #2d3748; font-size: 10pt; border: 1px solid #e2e8f0;\"\u003eParameter\u003c\/th\u003e\n      \u003cth style=\"padding: 8px; text-align: left; font-weight: bold; color: #2d3748; font-size: 10pt; border: 1px solid #e2e8f0;\"\u003eSpecification Details\u003c\/th\u003e\n    \u003c\/tr\u003e\n  \u003c\/thead\u003e\n  \u003ctbody\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0; width: 35%;\"\u003eModule Type\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003eFail-Safe Digital Output Module\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eModel Variants\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003eFC-SDO-04110 (Coated) \/ FS-SDO-04110 (Uncoated)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eChannel Count\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003e4 Channels (Fully tested for safety applications)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eOutput Rating\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003e110 V DC Solid-State Source, 325 mA max\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eSupply Voltage Range\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003e110 V DC (-15% to +25%)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eOn-State Voltage Drop\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003e\u0026lt; 2.5 V DC at 300 mA load\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eInternal Power Draw\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003e5V DC: 25 mA \/ 110V DC Internal: 10 mA\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #f8fafc;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eDimensions\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003e4 TE width, 3 HE height (4 HP x 3U rack space)\u003c\/td\u003e\n    \u003c\/tr\u003e\n    \u003ctr style=\"background-color: #ffffff;\"\u003e\n      \u003ctd style=\"padding: 8px; font-weight: bold; border: 1px solid #e2e8f0;\"\u003eCertifications\u003c\/td\u003e\n      \u003ctd style=\"padding: 8px; border: 1px solid #e2e8f0;\"\u003eCE, TUV, UL, CSA (Certified Safety Critical)\u003c\/td\u003e\n    \u003c\/tr\u003e\n  \u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003cp style=\"margin-bottom: 16px; padding: 0; font-size: 0; line-height: 0;\"\u003e \u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 14pt; margin-bottom: 12px;\"\u003eInstallation and Maintenance\u003c\/h2\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 6px;\"\u003eChassis Alignment and Safe Insertion\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eEnsure the 3U safety chassis power is stabilized before inserting the module. Slide the FC-SDO-04110 evenly along the slot rails until the heavy-duty rear connectors sit fully into the backplane. Hand-tighten front panel screws to secure the ground path and lock against vibrations.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 6px;\"\u003eHigh-Voltage Field Routing Rules\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eConnect external 110 V DC field power to the dedicated safety termination assembly. Ensure wiring insulation meets regional high-voltage regulations. Keep steady load capacitance under 1 µF to prevent inrush transients from tripping overcurrent loops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 16px;\"\u003eDiagnostic and Testing Routines\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eThe module constantly pulses its channels to run internal diagnostic loops. Ensure field-side actuators do not filter out or react to these micro-second test pulses, maintaining complete loop integrity without disturbing plant operations.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 16px; padding: 0; font-size: 0; line-height: 0;\"\u003e \u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 14pt; margin-bottom: 12px;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 6px;\"\u003eCompact 4 HP Safety Profile\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eWith a tight 4 horizontal pitch layout, this module delivers high-voltage, fail-safe digital outputs without consuming massive panel area. This helps engineers squeeze more safety channels into compact cabinets.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 6px;\"\u003eNegligible Off-State Leakage\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 12px;\"\u003eFeaturing an ultra-low leakage rating under 0.1 mA when turned off, the solid-state design prevents hazardous residual voltages from flowing downstream, removing the risk of unexpected actuator hangs.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #2c5282; font-size: 11pt; margin-top: 12px; margin-bottom: 16px;\"\u003eTrue SIL3 Ecosystem Alignment\u003c\/h3\u003e\n\u003cp style=\"margin-bottom: 16px;\"\u003eBuilt exclusively for emergency shutdown (ESD) and fire and gas (F\u0026amp;G) networks, this module integrates flawlessly into Safety Manager safety loops. It reduces configuration times and simplifies compliance validation.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 16px; padding: 0; font-size: 0; line-height: 0;\"\u003e \u003c\/p\u003e\n\n\u003ch2 style=\"color: #1a365d; font-size: 14pt; margin-bottom: 12px;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\n\u003cp style=\"margin-bottom: 8px; font-weight: bold; color: #2d3748;\"\u003eQ1: What separates the FC-SDO-04110 from the FS-SDO-04110 module variants?\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 16px; padding-left: 12px;\"\u003eA1: The FC-SDO-04110 variant features industrial conformal coating to protect the logic from dust, high moisture, and atmospheric chemicals. The FS-SDO-04110 uses an uncoated PCB optimized for clean, clean-room environments.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 8px; font-weight: bold; color: #2d3748;\"\u003eQ2: How does the SMOD function protect the plant if application logic locks up?\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 16px; padding-left: 12px;\"\u003eA2: SMOD bypasses standard application results entirely. If the firmware freezes or execution stops, the independent system watchdog opens the output lines directly via dedicated hardware logic, forcing a safe state.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 8px; font-weight: bold; color: #2d3748;\"\u003eQ3: Can these 110 V DC output lines drive standard low-voltage solenoids directly?\u003c\/p\u003e\n\u003cp style=\"margin-bottom: 16px; padding-left: 12px;\"\u003eA3: No. This module operates strictly on high-voltage 110 V DC logic. Attaching low-voltage field hardware will cause electrical damage. Ensure field equipment matches the 110 V DC operational thresholds.\u003c\/p\u003e\n\n\u003cp style=\"margin-bottom: 16px; padding: 0; font-size: 0; line-height: 0;\"\u003e \u003c\/p\u003e\n\n\u003cp style=\"font-weight: bold; margin-bottom: 0;\"\u003eCommercial Contact Email: \u003ca href=\"mailto:sale@etowonauto.com\" style=\"color: #1a365d; text-decoration: underline;\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51864139464836,"sku":"FC-SDO-04110","price":296.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/FC-SDO-04110.jpg?v=1778997963","url":"https:\/\/www.etowonauto.com\/az\/products\/fc-sdo-04110-honeywell-safety-manager-110v-do-card","provider":"Etowon Auto","version":"1.0","type":"link"}