{"product_id":"abb-gjr2312200r1010-88vk01a-e-relay-module-spdt-10a-24vdc","title":"ABB GJR2312200R1010 88VK01A-E Relay Module SPDT 10A 24VDC","description":"\u003ch2 style=\"color: #0056b3; font-size: 1.5em;\"\u003eABB GJR2312200R1010 88VK01A-E Relay Module\u003c\/h2\u003e\n\u003cp style=\"font-size: 1.05em; line-height: 1.6;\"\u003eThe \u003cb style=\"color: #0056b3;\"\u003eABB GJR2312200R1010 (88VK01A-E)\u003c\/b\u003e is an electromechanical relay module featuring SPDT contact configuration. Operating with a 24 V DC coil voltage, it handles maximum switching currents of 10 A and voltages up to 250 V AC. With insulation resistance ≥100 MΩ and contact ratings of AC1: 10 A \/ AC3: 6 A, this relay delivers reliable switching for industrial control circuits. Weighing 0.4 kg (14.4 oz), it operates from -40°C to +70°C.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 0.95em;\"\u003e\n\u003cthead style=\"background-color: #f2f4f6;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"padding: 10px; border: 1px solid #ccc; text-align: left;\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eManufacturer\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eProduct ID\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eGJR2312200R1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eABB Type Designation\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e88VK01A-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eRelay Type\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eElectromechanical Relay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eContact Configuration\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eSPDT (Single Pole Double Throw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eCoil Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMaximum Switching Current\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e10 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eMaximum Switching Voltage\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e250 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eInsulation Resistance\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e≥ 100 MΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eContact Rating\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eAC1: 10 A \/ AC3: 6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eDimensions\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e1.3 x 26.0 x 25.4 cm (0.5 x 10.3 x 10.0 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eWeight\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e0.4 kg (14.4 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ccc;\"\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eInstallation \u0026amp; Field Application Guide\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eMount the 0.4 kg relay module securely in the control cabinet.\u003c\/li\u003e\n\u003cli\u003eConnect 24 V DC coil supply. Verify polarity before energizing.\u003c\/li\u003e\n\u003cli\u003eWire load circuits to the SPDT contacts. Observe AC1 (10 A) and AC3 (6 A) rating limits for resistive and inductive loads.\u003c\/li\u003e\n\u003cli\u003eFor inductive loads, install an RC snubber across the contacts to suppress arcing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eWhy Choose the 88VK01A-E\u003c\/h3\u003e\n\u003cul style=\"margin-left: 20px; line-height: 1.8;\"\u003e\n\u003cli\u003eSPDT contact configuration provides versatile normally-open and normally-closed switching.\u003c\/li\u003e\n\u003cli\u003e10 A switching capacity handles heavy industrial loads.\u003c\/li\u003e\n\u003cli\u003eHigh insulation resistance (≥100 MΩ) ensures safe and reliable operation.\u003c\/li\u003e\n\u003cli\u003eWide operating temperature range (-40°C to +70°C) suits demanding environments.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch3 style=\"color: #0056b3; margin-top: 24px;\"\u003eField Engineer FAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ1:\u003c\/b\u003e What is the difference between AC1 and AC3 contact ratings?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA1:\u003c\/b\u003e AC1 (10 A) applies to resistive loads such as heaters and lamps. AC3 (6 A) applies to inductive motor loads with higher inrush currents.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ2:\u003c\/b\u003e What is the coil voltage of this relay?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA2:\u003c\/b\u003e The relay uses a 24 V DC coil for control circuit activation.\u003c\/p\u003e\n\u003cp\u003e\u003cb style=\"color: #0056b3;\"\u003eQ3:\u003c\/b\u003e Can this relay switch DC loads?\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eA3:\u003c\/b\u003e Yes, the contacts can switch DC loads within the rated current and voltage limits. For DC inductive loads, install a freewheeling diode across the load.\u003c\/p\u003e\n\n\u003cp style=\"margin-top: 24px;\"\u003eInquiries: \u003ca style=\"color: #0056b3; text-decoration: none; font-weight: bold;\" href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047935737988,"sku":"GJR2312200R1010","price":186.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/GJR2312200R1010.jpg?v=1792826958","url":"https:\/\/www.etowonauto.com\/az\/products\/abb-gjr2312200r1010-88vk01a-e-relay-module-spdt-10a-24vdc","provider":"Etowon Auto","version":"1.0","type":"link"}