{"product_id":"abb-di885-24-48v-dc-digital-input-module-3bse013088r1","title":"ABB DI885 24\/48V DC Digital Input Module | 3BSE013088R1","description":"\u003ch2\u003eABB DI885 Digital Input Module - Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eCore Product Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturer:\u003c\/strong\u003e ABB\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel Designation:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003eDI885\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Identification:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e3BSE013088R1\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Type:\u003c\/strong\u003e I\/O Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Weight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.3 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Specification:\u003c\/strong\u003e 24\/48V DC\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Type:\u003c\/strong\u003e Digital Input\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eElectrical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Channel Count:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e8 channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Compatibility:\u003c\/strong\u003e 24\/48V DC operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Rating:\u003c\/strong\u003e 50V rated isolation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE Functionality:\u003c\/strong\u003e Sequence of Event capability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e 1 group of 8 channels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e45 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e102 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e119 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight:\u003c\/strong\u003e \u003cstrong style=\"color: #2e86ab;\"\u003e0.3 kg\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eForm Factor:\u003c\/strong\u003e S800 I\/O standard\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Usage Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance Status:\u003c\/strong\u003e Not RoHS 2 2011\/65\/EU compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntended Use:\u003c\/strong\u003e Spare part for pre-July 2017 systems\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Scope:\u003c\/strong\u003e Repair, reuse, functionality updates\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Cut-off:\u003c\/strong\u003e Systems placed before July 22, 2017\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNew Installations:\u003c\/strong\u003e Not for new system installations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCompatibility Information\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompatible MTUs:\u003c\/strong\u003e TU810, TU812, TU814, TU830\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem Integration:\u003c\/strong\u003e S800 I\/O architecture\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Termination:\u003c\/strong\u003e Specified termination units\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSequence of Event Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE Capability:\u003c\/strong\u003e Sequence of Event recording\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent Timing:\u003c\/strong\u003e Precise event time-stamping\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eApplication Use:\u003c\/strong\u003e Event sequence monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Status:\u003c\/strong\u003e Not RoHS compliant\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Category:\u003c\/strong\u003e 5 - Small Equipment\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery Content:\u003c\/strong\u003e Zero batteries included\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Note:\u003c\/strong\u003e Legacy system component\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping and Customs\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHS Code:\u003c\/strong\u003e 853890\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCustoms Tariff:\u003c\/strong\u003e 85389099\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProduct Classification:\u003c\/strong\u003e Electrical machinery parts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePrimary Applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLegacy system maintenance and repair\u003c\/li\u003e\n\u003cli\u003eExisting automation system upgrades\u003c\/li\u003e\n\u003cli\u003ePre-2017 system component replacement\u003c\/li\u003e\n\u003cli\u003eSequence of event monitoring applications\u003c\/li\u003e\n\u003cli\u003eIndustrial control system maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Highlights\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e8-channel digital input for 24\/48V DC signals\u003c\/li\u003e\n\u003cli\u003eSequence of Event functionality for timing applications\u003c\/li\u003e\n\u003cli\u003e50V rated isolation for signal protection\u003c\/li\u003e\n\u003cli\u003eCompatible with specified termination units\u003c\/li\u003e\n\u003cli\u003eLegacy system spare part designation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003ch4\u003eWhat is the intended use of DI885?\u003c\/h4\u003e\n\u003cp\u003eThe \u003cstrong style=\"color: #2e86ab;\"\u003eDI885\u003c\/strong\u003e is a \u003cstrong style=\"color: #2e86ab;\"\u003espare part for systems installed before July 2017\u003c\/strong\u003e for maintenance and repair purposes only.\u003c\/p\u003e\n\u003ch4\u003eWhat voltage levels does it support?\u003c\/h4\u003e\n\u003cp\u003eThis module handles both \u003cstrong style=\"color: #2e86ab;\"\u003e24V and 48V DC input signals\u003c\/strong\u003e with 8-channel capacity.\u003c\/p\u003e\n\u003ch4\u003eIs this module RoHS compliant?\u003c\/h4\u003e\n\u003cp\u003eNo, the \u003cstrong style=\"color: #2e86ab;\"\u003eDI885 is not RoHS compliant\u003c\/strong\u003e and is intended only for legacy system maintenance.\u003c\/p\u003e\n\u003ch3\u003eContact Information\u003c\/h3\u003e\n\u003cp\u003eFor pricing information and technical support:\u003cbr\u003e\u003cstrong\u003eEmail: \u003c\/strong\u003e\u003ca href=\"mailto:sale@etowonauto.com\"\u003esale@etowonauto.com\u003c\/a\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050795532420,"sku":"3BSE013088R1","price":125.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/DI885.jpg?v=1763296023","url":"https:\/\/www.etowonauto.com\/az\/products\/abb-di885-24-48v-dc-digital-input-module-3bse013088r1","provider":"Etowon Auto","version":"1.0","type":"link"}