{"product_id":"abb-ci845-3bse075853r1-select-i-o-module","title":"ABB CI845 3BSE075853R1 Select I\/O Module","description":"\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eBrand:\u003c\/strong\u003e ABB\u003cbr\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e \u003cstrong\u003eCI845\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e Select I\/O \/ S800 I\/O\u003cbr\u003e\u003cstrong\u003eArticle Number:\u003c\/strong\u003e \u003cstrong\u003e3BSE075853R1\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe ABB \u003cstrong\u003eCI845\u003c\/strong\u003e \u003cstrong\u003e3BSE075853R1\u003c\/strong\u003e is an Ethernet Fieldbus Communication Interface Module (FCI) for the ABB Ability™ System 800xA automation platform. ABB designed this module for communications of \u003cstrong style=\"color: #c41e3a;\"\u003eS800 I\/O or Select I\/O\u003c\/strong\u003e to AC 800M controllers. Select I\/O provides \u003cstrong style=\"color: #2e8b57;\"\u003esingle channel granular signal conditioning\u003c\/strong\u003e for each field device.\u003c\/p\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCan be used as \u003cstrong style=\"color: #c41e3a;\"\u003esingle or redundant\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports both \u003cstrong style=\"color: #2e8b57;\"\u003eSelect I\/O and S800 on Ethernet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eSupports \u003cstrong style=\"color: #c41e3a;\"\u003e12 single or 12 redundant\u003c\/strong\u003e S800 I\/O modules\u003c\/li\u003e\n\u003cli\u003eSupports up to \u003cstrong style=\"color: #2e8b57;\"\u003e192 Select I\/O channels\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eHART v7, HART pass-through\u003c\/strong\u003e with HART variables to application\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e8b57;\"\u003eSequence of Events (SOE)\u003c\/strong\u003e support\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eHot swap\u003c\/strong\u003e supported\u003c\/li\u003e\n\u003cli\u003eCan be used in \u003cstrong style=\"color: #2e8b57;\"\u003ehazardous area\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eBuilt-in diagnostics:\u003c\/strong\u003e power supervision, cabinet temperature, communication supervision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e8b57;\"\u003eSoft marshalling\u003c\/strong\u003e and optimized engineering\u003c\/li\u003e\n\u003cli\u003eMechanical \u003cstrong style=\"color: #c41e3a;\"\u003elocking slider\u003c\/strong\u003e turns off power before removal\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #2e8b57;\"\u003eMechanical keying\u003c\/strong\u003e and LED indicators\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommunication Protocol:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eEthernet\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eType:\u003c\/strong\u003e Ethernet FCI Module\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaster or Slave:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eSlave\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHART:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eYes\u003c\/strong\u003e (v7, pass-through)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSOE:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eYes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRedundancy:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eYes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot Swap:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eYes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanics:\u003c\/strong\u003e Select I\/O\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eDetailed Data\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation:\u003c\/strong\u003e Galvanic isolation between power supply and I\/O modules\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e Internal hardware supervision, communication supervision, internal power supervision, supervision of incoming system power A and B, cabinet temperature supervision\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e5 W\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation in Hazardous Area\/Locations:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eYes\/Yes\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e19.2 ... 30 V\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eEnvironmental and Certification\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e-40 °C to +70 °C\u003c\/strong\u003e (-40 °F to 158 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003e-40 °C to +85 °C\u003c\/strong\u003e (-40 °F to 185 °F)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePollution Degree:\u003c\/strong\u003e Degree 2 acc. to IEC 60664-1\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e5 to 95%\u003c\/strong\u003e, non-condensation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAltitude:\u003c\/strong\u003e -1000 to 5000 m (restrictions apply)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProtection Class:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eIP20\u003c\/strong\u003e acc. to IEC 60529\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCE-marking:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eUKCA:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCorrosive Atmosphere:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eG3\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eSafety and Approvals\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e IEC\/EN 61010-1, UL 61010-1, CSA-C22.2 No. 61010-1-12, IEC\/EN 61010-2-201, UL 61010-2-201, CSA C22.2 No. 61010-2-201\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMarine Certification:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eDNV, ABS\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area ATEX:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003eII 3G Ex nA IIC T4 Gc, II 3G Ex ec IIC T4 Gc, II 3G Ex ic nA IIC T4 Gc, II 3G Ex ic ec IIC T4 Gc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area IECEx:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eII 3G Ex nA IIC T4 Gc, II 3G Ex ec IIC T4 Gc, II 3G Ex ic nA IIC T4 Gc, II 3G Ex ic ec IIC T4 Gc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location US\/CAN:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003ecULus CL I, ZN 2, AEx ec IIC T4 Gc, Ex ec IIC T4 Gc X, CL I, ZN 2, AEx nA IIC T4 Gc, Ex nA IIC T4 Gc X, CL I, DIV 2, Groups A-D T4\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area CCC:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003eEx ec IIC T4 Gc, Ex ec ic IIC T4 Gc\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRoHS Compliance:\u003c\/strong\u003e EU RoHS, UAE RoHS, CN RoHS\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWEEE Compliance:\u003c\/strong\u003e EU\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eDimensions and Weight\u003c\/h2\u003e\n\u003cul style=\"text-align: center; list-style-type: none; padding-left: 0;\"\u003e\n\u003cli\u003e\n\u003cstrong\u003eWidth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003e30 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeight:\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e135 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDepth:\u003c\/strong\u003e \u003cstrong style=\"color: #2e8b57;\"\u003e121.7 mm\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight (including base):\u003c\/strong\u003e \u003cstrong style=\"color: #c41e3a;\"\u003e225 g\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003ePackage Includes\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e1x ABB \u003cstrong\u003eCI845\u003c\/strong\u003e \u003cstrong\u003e3BSE075853R1\u003c\/strong\u003e Ethernet FCI module\u003c\/li\u003e\n\u003cli\u003e1x installation manual\u003c\/li\u003e\n\u003cli\u003e1x certification document\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eShipping\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong style=\"color: #c41e3a;\"\u003eFedEx, UPS, DHL\u003c\/strong\u003e express worldwide\u003c\/li\u003e\n\u003cli\u003eShips within \u003cstrong style=\"color: #2e8b57;\"\u003e24 hours\u003c\/strong\u003e from stock\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #0066cc; font-weight: bold; text-align: center;\"\u003eFAQ\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e1. What is the article number for this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe article number is \u003cstrong style=\"color: #c41e3a;\"\u003e3BSE075853R1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2. What I\/O systems does the CI845 support?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIt supports both \u003cstrong style=\"color: #2e8b57;\"\u003eSelect I\/O and S800 I\/O on Ethernet\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e3. Does the CI845 support redundancy?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. It can be used as \u003cstrong style=\"color: #c41e3a;\"\u003esingle or redundant\u003c\/strong\u003e with two CI845 modules.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050500161668,"sku":"CI845","price":196.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CI845-1.jpg?v=1771330261","url":"https:\/\/www.etowonauto.com\/az\/products\/abb-ci845-3bse075853r1-select-i-o-module","provider":"Etowon Auto","version":"1.0","type":"link"}