{"product_id":"abb-3bse031155r1-redundancy-module-advant-ac800m","title":"ABB 3BSE031155R1 Redundancy Module | Advant AC800M","description":"\u003ch2 style=\"color:#0055A4;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong style=\"color:#0055A4;\"\u003eBC810K02 (3BSE031155R1)\u003c\/strong\u003e is an ABB Redundancy Module for the Advant AC800M series. This high integrity module supports hot swap for improved system uptime. It ensures seamless controller redundancy in critical process applications.\u003c\/p\u003e\n\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eBC810K02 (3BSE031155R1)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eABB\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eSeries\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eAdvant AC800M\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eRedundancy\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eYes, supports redundancy for high availability\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eIntegrity\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eHigh Integrity\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eHot Swap Support\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eYes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003ePower Supply Inputs\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e24 V DC nominal (19.2 to 30 V DC)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e50 mA typical, 70 mA maximum at 24 V\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003ePower Dissipation\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1.2 W typical\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eEnvironmental Specifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003e+5°C to +55°C (+41°F to +131°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e-40°C to +70°C (-40°F to +158°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eProtection Class\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eIP20 (EN60529, IEC 529)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eCorrosion Protection\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eISA-S71.04 G3\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eEMC Compliance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eCE, FCC Class A certified\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eIEC 60068-2-6\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eIEC 60068-2-27\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eSafety \u0026amp; Certifications\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eCE Marking\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003eYes\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eElectrical Safety\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eUL 61010-1, UL 61010-2-201 certified\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eHazardous Location Rating\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003ecULus Class 1, Zone 2, AEx nA IIC T4, ExnA IIC T4Gc X\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eMarine Certifications\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eABS, BV, DNV-GL, LR\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eRoHS Compliance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eYes (EN 50581:2012)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWEEE Compliance\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eYes (Directive 2012\/19\/EU)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eFunctional Safety\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003eIEC 61508 and IEC 61511 compliant\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eDimensions \u0026amp; Weight\u003c\/h3\u003e\n\u003ctable width=\"100%\" border=\"0\" cellpadding=\"8\" cellspacing=\"0\" style=\"border-collapse:collapse;\"\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd width=\"40%\"\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd width=\"60%\"\u003e59 mm (2.9 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e185 mm (7.3 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr style=\"background-color:#f5f5f5;\"\u003e\n    \u003ctd\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e127.5 mm (5.0 inches)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n    \u003ctd\u003e1.5 kg (3.31 lbs) including base\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch3\u003eInstallation Guide\u003c\/h3\u003e\n\u003cp\u003eMount the BC810K02 in an Advant AC800M rack system. Connect 24 V DC power within 19.2 to 30 V DC range. The module supports hot swap — no power down required for replacement. Ensure IP20 enclosure protection for indoor installation. Observe Class 1 Zone 2 hazardous location precautions.\u003c\/p\u003e\n\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cp\u003eThe BC810K02 provides seamless controller redundancy for high availability systems. High integrity design meets IEC 61508 and IEC 61511 functional safety standards. Marine certifications (ABS, BV, DNV-GL, LR) enable offshore and shipboard use. Corrosion protection rated ISA-S71.04 G3 for harsh industrial environments.\u003c\/p\u003e\n\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1:\u003c\/strong\u003e What is the difference between BC810K01 and BC810K02?\u003cbr\u003e\n\u003cstrong\u003eA1:\u003c\/strong\u003e BC810K02 includes high integrity certification for safety-critical applications. BC810K01 is standard integrity.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2:\u003c\/strong\u003e Can I hot swap this module while the system is running?\u003cbr\u003e\n\u003cstrong\u003eA2:\u003c\/strong\u003e Yes. The BC810K02 supports hot swap replacement without powering down the AC800M system.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3:\u003c\/strong\u003e What is the maximum power consumption at 30 V DC?\u003cbr\u003e\n\u003cstrong\u003eA3:\u003c\/strong\u003e Maximum current is 70 mA at 24 V. At 30 V DC, power consumption increases proportionally but remains under 2.1 W.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51047928889476,"sku":"3BSE031155R1","price":195.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/3BSE031155R1.jpg?v=1780146354","url":"https:\/\/www.etowonauto.com\/az\/products\/abb-3bse031155r1-redundancy-module-advant-ac800m","provider":"Etowon Auto","version":"1.0","type":"link"}