{"product_id":"abb-3bdh000692r1-ci920an-advant-800xa-communication-interface","title":"ABB 3BDH000692R1 CI920AN Advant 800xA Communication Interface","description":"\u003ch2\u003eCore Technical Advantages\u003c\/h2\u003e\n\u003ch3\u003eSeamless HART Field Device Pass-Through\u003c\/h3\u003e\n\u003cp\u003eThe CI920AN natively supports HART protocol bridging over the PROFIBUS DP network configuration. This allows maintenance engineering teams to perform asset management operations, calibrate remote transmitters, change process parameters, and view advanced health metrics directly from the central control room without running dedicated secondary instrumentation wires.\u003c\/p\u003e\n\u003ch3\u003eAdvanced System and Network Redundancy\u003c\/h3\u003e\n\u003cp\u003eTo maximize uptime in critical continuous-process environments, the CI920AN supports full master\/slave line redundancy. If a primary master module failure or a network cable break is detected, the redundant standby configuration takes over the communication bus instantaneously, ensuring zero data drops or unexpected automated plant shutdowns.\u003c\/p\u003e\n\u003ch3\u003eRugged S900 Modular Architecture\u003c\/h3\u003e\n\u003cp\u003ePart of the rugged S900 system platform, the CI920AN features an extremely small physical footprint (20mm thickness), optimizing DIN rail real estate inside control marshaling panels. Its energy-efficient internal circuitry generates minimal thermal load, contributing to its broad ambient operating spectrum and long-term lifespan.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n\u003cthead\u003e\n\u003ctr style=\"background-color: #f2f2f2; border-bottom: 2px solid #ddd;\"\u003e\n\u003cth style=\"padding: 10px; text-align: left; border: 1px solid #ddd;\"\u003eParameter Code\u003c\/th\u003e\n\u003cth style=\"padding: 10px; text-align: left; border: 1px solid #ddd;\"\u003eSpecification Details\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eBrand \/ Manufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eABB Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eCatalog Part Number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e3BDH000692R1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eModel Identification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCI920AN (Non-IS Version)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eSignal \/ Module Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003ePROFIBUS DP Remote I\/O Communication Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eHART Protocol Compatibility\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eYes (Supports cyclic and acyclic HART parameter routing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eRedundancy Support\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eYes (Supports dual redundant network line topologies)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eMechanical Classification\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eS900 Sub-rack Mountable Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eDimensions (W x D x H)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e20 x 104 x 104 mm (0.79 x 4.09 x 4.09 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eOperating Temperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f9f9f9;\"\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003e\u003cstrong\u003eEnvironmental Compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 10px; border: 1px solid #ddd;\"\u003eCE Marked, RoHS Directive 2011\/65\/EU, WEEE Small Equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eInstallation and Maintenance\u003c\/h2\u003e\n\u003ch3\u003eS900 Slot Mounting and Hot-Swap Guidelines\u003c\/h3\u003e\n\u003cp\u003eThe CI920AN is engineered to snap directly into the designated communication slots on an S900 terminal unit or backplane chassis. To install, align the rear connector pin layout with the sub-rack guide tracking channels and press firmly until the locking tabs snap into place. The module supports live-insertion\/hot-swapping configurations, allowing maintenance teams to change components without interrupting power to the remaining active I\/O rack segments.\u003c\/p\u003e\n\u003ch3\u003eRedundant Bus Line Termination and Configuration\u003c\/h3\u003e\n\u003cp\u003eWhen implementing redundant topologies, install dual CI920AN modules into the corresponding primary and secondary sub-rack slots. Ensure the interconnecting PROFIBUS DP cables are terminated using high-quality network plugs with integrated terminating resistors active on both ends of the segment to avoid signal reflections and data communication corruption.\u003c\/p\u003e\n\u003ch3\u003eClimatic Control and Environmental Preservation\u003c\/h3\u003e\n\u003cp\u003eThe module is certified to perform across a broad temperature scale (-20°C to 60°C) and withstand non-condensing relative humidity levels up to 93% (±3% at 40°C). For outdoor marshaling applications or environments high in ambient particulate count, house the S900 system sub-rack assembly within a sealed, climate-controlled cabinet matching IP65 or NEMA 4 standards.\u003c\/p\u003e\n\u003ch2\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3\u003eDirect System 800xA Optimization\u003c\/h3\u003e\n\u003cp\u003eBy routing field information through standard PROFIBUS DP layers, the CI920AN offers smooth integration with ABB’s core asset optimization software utilities. This integration maps process inputs, diagnostic registers, and status alerts directly into the operator workstation environment without requiring complex ladder logic rewriting.\u003c\/p\u003e\n\u003ch3\u003eReduced Engineering and Wiring Overhead\u003c\/h3\u003e\n\u003cp\u003eCombining many analog and digital I\/O clusters onto a single serial communication line reduces the total volume of field cables running back to the main control station. This distributed I\/O framework simplifies project engineering, lowers installation costs, and reduces the time required for system commissioning.\u003c\/p\u003e\n\u003ch3\u003eComprehensive Compliance Standards\u003c\/h3\u003e\n\u003cp\u003eComplying with strict European CE mandates, RoHS Directive 2011\/65\/EU, and falling into the WEEE Small Equipment category (external dimensions ≤ 50cm), this module meets environmental and electronic safety standards required for global infrastructure, power generation, and manufacturing applications.\u003c\/p\u003e\n\u003ch2\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the CI920AN 3BDH000692R1 be installed directly in ATEX Zone 1 hazardous explosive zones?\u003c\/strong\u003e\u003cbr\u003eA1: No. While the S900 family contains modules specifically engineered for intrinsically safe field areas, the CI920AN (Model Code ending with 'N') is classified as a non-intrinsically safe interface module. It should be mounted inside a safe area or within a flame-proof \/ purged enclosure when used in hazardous industrial settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How does the CI920AN handle a sudden failure of the primary PROFIBUS line?\u003c\/strong\u003e\u003cbr\u003eA2: When deployed in a redundant configuration with a secondary backup module, both units monitor network status in real time. If the active communication channel fails or experiences a broken cable, the internal firmware switches to the redundant link within milliseconds, ensuring uninterrupted control loop data tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does this module require specialized software toolsets for initial node address assignment?\u003c\/strong\u003e\u003cbr\u003eA3: Initial node station addresses can typically be configured using standard hardware configuration switches located on the module\/backplane housing, or established via PROFIBUS network master configuration software utilities during system integration.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":51050500882564,"sku":"CI920AN","price":176.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/CI920AN.jpg?v=1783605250","url":"https:\/\/www.etowonauto.com\/az\/products\/abb-3bdh000692r1-ci920an-advant-800xa-communication-interface","provider":"Etowon Auto","version":"1.0","type":"link"}