{"product_id":"5094-iy8-allen-bradley-flex-5000-8-channel-multi-analog","title":"5094-IY8 Allen-Bradley | FLEX 5000 8-Channel Multi-Analog","description":"\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eProduct Overview\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 5094-IY8\u003c\/strong\u003e is a highly versatile \u003cstrong\u003eFLEX 5000 Multi-Input Analog Module\u003c\/strong\u003e designed to simplify complex sensor integration in industrial automation. This universal module features \u003cstrong\u003e8 high-resolution channels\u003c\/strong\u003e capable of interfacing with a wide variety of inputs, including Voltage, Current, RTDs (Platinum, Nickel, Copper), and multiple Thermocouple types (B, C, E, J, K, R, S, T). Utilizing a 24-bit sigma-delta ADC, the 5094-IY8 provides exceptional precision for process temperature monitoring, flow rate measurement, and HVAC control. Weighing just \u003cstrong\u003e0.143 kg (0.31 lbs)\u003c\/strong\u003e, it offers a compact and high-density solution for modern Logix 5000 control systems.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; margin: 15px 0;\"\u003e\n  \u003ctr\u003e\n    \u003cth style=\"border: 1px solid #000; padding: 10px; text-align: left;\"\u003eParameter\u003c\/th\u003e\n    \u003cth style=\"border: 1px solid #000; padding: 10px; text-align: left;\"\u003eSpecification\u003c\/th\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eBrand \/ Series\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eAllen-Bradley \/ FLEX 5000\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eModel Number\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e5094-IY8\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eInput Channels\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e8 Differential or Single-Ended\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eADC Resolution\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e24-Bit Sigma-Delta\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eVoltage Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e±10V, 0-10V, 0-5V, ±100mV\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eCurrent Range\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e0-20mA, 4-20mA\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eIsolation\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e250V AC Channel-to-Channel\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eOperating Temp\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e-20°C to 70°C (-4°F to 158°F)\u003c\/td\u003e\n  \u003c\/tr\u003e\n  \u003ctr\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003eModule Weight\u003c\/td\u003e\n    \u003ctd style=\"border: 1px solid #000; padding: 10px;\"\u003e0.143 kg (0.31 lbs)\u003c\/td\u003e\n  \u003c\/tr\u003e\n\u003c\/table\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eEngineering Advantages\u003c\/h2\u003e\n\u003ch3 style=\"color: #333;\"\u003eUniversal Input Flexibility\u003c\/h3\u003e\n\u003cp\u003eThe 5094-IY8 eliminates the need for separate thermocouple, RTD, and analog modules. By supporting mixed signal types on a single 8-channel bank, engineers can reduce spare parts inventory and save valuable cabinet space. Whether monitoring industrial oven temperatures via a K-type thermocouple or tank levels via 4-20mA pressure transducers, this module adapts to the specific needs of the process.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eSuperior 24-Bit Signal Integrity\u003c\/h3\u003e\n\u003cp\u003ePrecision is critical in chemical and thermal processing. The \u003cstrong\u003e24-bit sigma-delta ADC\u003c\/strong\u003e resolution ensures that even the smallest variations in sensor data are captured. Coupled with 100dB common-mode rejection at 60Hz and channel-to-channel isolation, the 5094-IY8 provides clean, stable data in environments plagued by electrical noise and ground loops.\u003c\/p\u003e\n\n\u003ch3 style=\"color: #333;\"\u003eRugged Environmental Reliability\u003c\/h3\u003e\n\u003cp\u003eDesigned for deployment in diverse climates, the module operates reliably from \u003cstrong\u003e-20°C to 70°C\u003c\/strong\u003e. It features robust vibration immunity (2.5g) and EMC compatibility (IEC 61326-1), making it suitable for heavy industrial applications where machinery movement and electromagnetic interference are common factors.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eInstallation \u0026amp; Wiring Guide\u003c\/h2\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use shielded twisted-pair cables (22-14 AWG) for all analog signals to minimize noise. To prevent ground loops, ensure the cable shield is grounded at one end only.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTerminal Base:\u003c\/strong\u003e This module requires a separate FLEX 5000 terminal base for installation. The removable terminal blocks (RTB) allow for rapid module replacement without disconnecting individual field wires.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePower Configuration:\u003c\/strong\u003e Provide a stabilized 18-32V DC external supply for field-side power. Monitor the power dissipation (2.8W max) when designing high-density enclosures to ensure adequate cooling.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSoftware Setup:\u003c\/strong\u003e Configuration is performed through module-defined tags in \u003cstrong\u003eStudio 5000 Logix Designer\u003c\/strong\u003e. Select the specific input type (e.g., Thermocouple J or 4-20mA) for each channel to enable the appropriate scaling and diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #005596; font-weight: bold;\"\u003eTechnical FAQs\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the 5094-IY8 provide cold-junction compensation for thermocouples?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA1: Yes, the module provides integrated cold-junction compensation to ensure high-accuracy thermocouple readings (typically ±1°C) across the entire operating temperature range.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ2: Can I mix voltage and current inputs on the same module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA2: Yes, each of the 8 channels can be independently configured for any of the supported voltage, current, RTD, or thermocouple ranges through the software configuration.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eQ3: What is the recommended calibration interval for this Allen-Bradley module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA3: To maintain the specified accuracy (±0.1% for voltage), a calibration interval of every 2 years is recommended, though specific industry regulations may require more frequent checks.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51047906115716,"sku":"5094-IY8","price":156.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0958\/7454\/7844\/files\/5094-IY8.jpg?v=1778411017","url":"https:\/\/www.etowonauto.com\/az\/products\/5094-iy8-allen-bradley-flex-5000-8-channel-multi-analog","provider":"Etowon Auto","version":"1.0","type":"link"}